2.1.15 What should I do if the indicator of a phone is off when the
phone is picked up?
Symptom
The IAD registration status is normal but the indicator of a connected phone is off when the
user picks up the phone.
Possible Cause
The possible causes are as follows:
The phone is faulty.
The device is faulty.
The subscriber line is unavailable.
The power supply is abnormal.
Solution
Step 1
Replace the phone with another one.
If the problem does not occur, the origina l phone is faulty. Replace the original phone.
If the problem persists, go to
Step 2
Connect the phone to the telephone line of the IAD and check whether there is feed.
If yes, ensure that the cables in the cable distribution frame (CDF) are correctly
connected.
If no, go to
Step 3
Use a telephone line delivered with the device to replace the existing one.
If the problem is resolved, the procedure ends.
If the problem persists, go to
Step 4
Replace the board.
If the problem is resolved, the procedure ends.
If the problem persists, go to
Step 5
Check the power supply, especial at small ports.
IAD1224: 110/220 V AC or 48 V DC.
IAD132E(T): 100-240 V AC
IAD208E(M ) and IAD104H: 12 V DC (using the power adapter to convert 100-240 V AC to 12 V
DC)
IAD101/102H: 5V DC (using the power adapter to convert 100-240 V AC to 5 V DC)
If yes, go to
If no, select the correct power supply.
Step 6
Contact Huawei technical support engineers.
----End