The subcommand is used to set the SSD SN. The host uses PRP1 and PRP2 to send SN
information in the format described in
Table A-84
SN
Bytes
Description
19:00
SN
l
FLASH ID
This command is used to obtain the FLASH ID. This command uses PRP1, PRP2, and
Dword10. The data length is specified by Dword10 (fixed at 2).
Table A-85
FLASH ID
BIT
Description
63:00
FLASH ID
A.6.2.1.3 Obtaining the Enablement Status of Functions
This command is used to obtain the enablement status of a customized function through the
controller. The PF and VF have the permission to run this command based on controller
access.
This command uses the PRP1, PRP2, Dword10, and Dword12 fields. Enter reserved value 0
for other fields that are not involved.
Sub_OpType indicates the function type.
Table A-86
Sub_OpType
Sub_OpType
Description
01h
Flash inspection enablement
02h
Capacitor inspection enablement
03h
DDR inspection enablement
04h
Temperature inspection enablement
06h
CE concurrency enablement
07h
Read Retry enablement
08h
Wear leveling enablement
09h
Inter-chip RAID enablement
0ah
Garbage collection (GC) enablement
ES3000 V5 NVMe PCIe SSD
User Guide
A Supported NVMe Commands
Issue 07 (2019-03-19)