NOTE
If the 2G inter-RAT neighboring cells also exist, however, the UE may be handed over to a 2G or 3G
neighboring cell. This is determined by the parameter setting. For details, see
ePico3801 Parameters Related to the Handover to 3G Macro Cells
Procedure
Step 1
Log in to the APM. Choose
Configuration
>
Single Configuration
and select an ePico3801 to
be maintained. Then, click
Configure
to enter the configuration window.
Step 2
Choose
Terminal Parameter
>
WIRELESS
>
Configuration
in the navigation tree to
configure the 3G macro neighboring cell parameters.
1.
Choose
NRNC
to set the information about the neighboring RNCs.
2.
Choose
NRNCCELL
to add, delete, or modify the cells controlled by the neighboring
RNCs.
3.
Choose
INTERFREQNCELL
to add, delete, or modify the inter-frequency neighboring
cells.
4.
Choose
INTRAFREQNCELL
to add, delete, or modify the intra-frequency neighboring
cells.
NOTE
l
, and
can be executed only after the information about
the neighboring RNCs is configured.
l
For details about how to set the parameters, see
Help
in the corresponding configuration window.
Step 3
After the parameter setting is complete, click
Apply
. A system message is displayed, indicating
whether the parameter setting is successful.
----End
5.4.2 Modifying 2G Macro Neighboring Cells
This chapter describes how to manually add 2G macro neighboring cells on the AP Manager
(APM). This operation can be performed only in manual network planning mode.
Prerequisite
l
The parameters of the ePico zone have been set successfully.
l
You have logged in to the APM. The login account belongs to the Administrator or
Operators group.
Context
If the signal quality of a UE in an AP cell is poor, the UE needs to be handed over to a 2G inter-
RAT neighboring cell. In this case, the information about 2G neighboring cells needs to be
configured. If both the 2G and 3G neighboring cells exist, the UE is handed over to a 3G
neighboring cell by default. If you require the UE to be handed over to a 2G neighboring cell,
you need to run the
HOCOMM
command in the APM window to change the related parameter
setting. For details, see
5.4.5 Modifying the ePico3801 Parameters Related to the Handover
.
5 Reconfiguring the ePico3801
ePico3801
User Guide
5-6
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2009–09–23)