background image

2.1 Functions of the EMUA

This describes the functions of the EMUA. Providing a variety of input ports for monitoring
signals, the EMUA supports real-time monitoring and remote monitoring. In addition, the
EMUA is highly reliable and can be flexibly configured. It supports a large area for temperature
monitoring.

Functions of the EMUA

Power Input

The EMUA supports input voltage detection. The alarm threshold for the input voltage can be
configured on the BTS/NodeB and delivered to the EMUA.

The EMUA provides two power input ports, which are protected from inverse connections.

l

The EMUA2416 and EMUA2432 s24 V DC power input, and the voltage can
range from +18 V DC to +36 V DC.

l

The EMUA4832 supports -48 V DC power input, and the voltage can range from -36 V
DC to -72 V DC.

Environment Monitoring

l

The EMUA provides an independent port for +12 V/+24 V DC current-type (4 mA - 20
mA) humidity/temperature sensors. The temperature monitoring range is -20

o

C [-4

o

F] to

80

o

C [176

o

F].

l

The EMUA provides four ports for monitoring analog signals. Voltage-type (0 V - 5 V)
sensors and current-type (4 mA - 20 mA) sensors can be used. The types of monitored
analog signals can be configured through the DIP switch settings according to the BTS/
NodeB configuration.

Boolean Signal Monitoring

The EMUA provides ports for monitoring Boolean signals. Dry contact point signals and OC
signals are supported.

l

The EMUA2416 supports 16 ports for Boolean signal monitoring.

l

The EMUA2432 or EMUA4832 supports 32 ports for Boolean signal monitoring.

Relay Node Control

The EMUA provides six output control ports for external Boolean signals of the relay node type.

Communication Ports

The EMUA provides two RS-485 ports, which are used for the communication between the
EMUA and the BTS/NodeB.

Comparison Between the Functions of the Three EMUA Models

Table 2-1

 lists the functions of the three EMUA models for you to make a comparison.

2 Overview of the EMUA

EMUA

User Guide

2-2

Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

Issue 10 (2010-03-30)

Содержание EMUA Series

Страница 1: ...EMUA V100R001 User Guide Issue 10 Date 2010 03 30 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd ...

Страница 2: ... in this document are the property of their respective holders Notice The purchased products services and features are stipulated by the contract made between Huawei and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommenda...

Страница 3: ...or the Door Status Sensor 2 16 2 5 5 Monitoring Port for the Humidity Temperature Sensor 2 17 2 5 6 Monitoring Port for Boolean Signals 2 18 2 5 7 Monitoring Port for Analog Signals 2 19 2 5 8 Monitoring Port for the Relay Node Boolean Signals 2 21 2 6 Technical Specifications of the EMUA 2 23 3 Introduction to the Sensors 3 1 3 1 Water Sensor 3 2 3 2 Smoke Sensor 3 2 3 3 Infrared Sensor 3 4 3 4 D...

Страница 4: ...the Door Status Sensor 5 7 5 5 Installing the Humidity Temperature Sensor 5 9 6 Commissioning the EMUA 6 1 7 Handling Common Faults 7 1 Contents EMUA User Guide ii Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 10 2010 03 30 ...

Страница 5: ...t for Boolean signals 2 19 Figure 2 18 Monitoring port for analog signals 2 20 Figure 2 19 Connecting the analog sensor of the voltage type 2 21 Figure 2 20 Connecting the analog sensor of the current type 2 21 Figure 2 21 Monitoring Port for relay node Boolean signals 2 22 Figure 2 22 Cable connection of the relay node 2 22 Figure 3 1 Exterior of the YW517B water sensor 3 2 Figure 3 2 Exterior of...

Страница 6: ...the smoke sensor 5 6 Figure 5 5 Connecting the infrared sensor 5 7 Figure 5 6 Connecting the AGX105F door status sensor 5 8 Figure 5 7 Connecting the HO 03A door status sensor 5 8 Figure 5 8 Connecting the humidity temperature sensor 5 10 Figures EMUA User Guide iv Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 10 2010 03 30 ...

Страница 7: ...nals of the monitoring port for Boolean signals 2 19 Table 2 13 Meanings of the terminals of the monitoring port for analog signals 2 20 Table 2 14 Meanings of the terminals of the monitoring port for relay node Boolean signals 2 22 Table 2 15 Alarms corresponding to the relay switch 2 23 Table 2 16 Technical specifications of the EMUA 2 23 Table 2 17 Performance specifications of the EMUA 2 24 Ta...

Страница 8: ......

Страница 9: ...ct version related to this document Product Name Product Version EMUA2416 V100R001 EMUA2432 V100R001 EMUA4832 V100R001 Intended Audience This document is intended for l NodeB BTS Installer l System Engineer l Site Maintainer Change History For changes made in this document refer to 1 Changes in EMUA User Guide Organization 1 Changes in EMUA User Guide EMUA User Guide About This Document Issue 10 2...

Страница 10: ...mmission the EMUA 7 Handling Common Faults This describes the solutions to common faults in the EMUA Conventions Symbol Conventions The symbols that may be found in this document are defined as follows Symbol Description Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium or low level of risk which if not avoided...

Страница 11: ...ped in brackets and separated by vertical bars One item is selected or no item is selected x y Optional items are grouped in braces and separated by vertical bars A minimum of one item or a maximum of all items can be selected x y Optional items are grouped in brackets and separated by vertical bars Several items or no item can be selected GUI Conventions The GUI conventions that may be found in t...

Страница 12: ...use Operations The mouse operations that may be found in this document are defined as follows Action Description Click Select and release the primary mouse button without moving the pointer Double click Press the primary mouse button twice continuously and quickly without moving the pointer Drag Press and hold the primary mouse button and move the pointer to a certain position About This Document ...

Страница 13: ...rance description the EMUA is modified 06 2008 05 20 Sixth release The pin mapping description of the data cable is added 05 2008 04 25 Fifth release The illustration of how to connect the infrared sensor is modified 04 2008 01 15 Fourth release The title of the preface is changed the document structure is adjusted and the procedure for installing the EMUA on a wall is added 03 2007 04 20 Third re...

Страница 14: ...2 Second release Testing problems are solved 01 2007 01 15 First release 1 Changes in EMUA User Guide EMUA User Guide 1 2 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 10 2010 03 30 ...

Страница 15: ...tructure of the EMUA This describes the internal structure of the EMUA 2 4 Communication Ports on the EMUA The EMUA provides the RS485 and RS232 ports for the communication between the EMUA and the BTS NodeB Specifically the EMUA4832 provides an independent commissioning port 2 5 Monitoring Ports of the EMUA The EMUA provides monitoring ports for the humidity temperature sensor smoke sensor water ...

Страница 16: ...emperature monitoring range is 20oC 4oF to 80oC 176oF l The EMUA provides four ports for monitoring analog signals Voltage type 0 V 5 V sensors and current type 4 mA 20 mA sensors can be used The types of monitored analog signals can be configured through the DIP switch settings according to the BTS NodeB configuration Boolean Signal Monitoring The EMUA provides ports for monitoring Boolean signal...

Страница 17: ...ttings You can set the DIP switches SW24A and SW24B You can set the DIP switches SW24A and SW24B Serial port protection Maximum current in differential mode 3 kA maximum current in common mode 5 kA Maximum current in differential mode 3 kA maximum current in common mode 5 kA Maximum current in differential mode 3 kA maximum current in common mode 5 kA 2 2 Exterior of the EMUA Each Module of EMUA h...

Страница 18: ...15 S14 S14 S13 S13 S24 S24 S23 S23 S22 S22 S21 S21 S32 S32 S31 S31 S30 S30 S29 S29 1 Indicator 2 Four ports for analog signal sensors 3 Port for infrared sensors 4 Port for smoke sensors 5 Port for door status sensors 6 Six ports for Boolean signal output 7 16 32 ports for the detection of Boolean signals 8 Two RS 485 ports 9 Wiring terminal for the power supply 10 Port for humidity temperature se...

Страница 19: ... S24 S24 S23 S23 S22 S22 S21 S21 S32 S32 S31 S31 S30 S30 S29 S29 1 Indicator 2 Four ports for analog signal sensors 3 Port for infrared sensors 4 Port for smoke sensors 5 Port for door status sensors 6 Six ports for Boolean signal output 7 16 32 ports for Boolean signal monitoring 8 Two RS 485 ports 9 Wiring terminal for the power supply 10 Port for humidity temperature sensors 11 Port for water s...

Страница 20: ...24 S23 S23 S22 S22 S21 S21 S32 S32 S31 S31 S30 S30 S29 S29 1 Indicator 2 Four ports for analog signal sensors 3 Port for infrared sensors 4 Port for smoke sensors 5 Port for door status sensors 6 Six ports for Boolean signal output 7 16 32 ports for the detection of Boolean signals 8 Two RS 485 ports 9 Wiring terminal for the power supply 10 Port for humidity temperature sensors 11 Port for water ...

Отзывы: