The voltage-type analog sensor has two power input terminals (marked "POWER+" and
"POWER-") and one analog signal output terminal (marked "Sout"), as shown in
.
Figure 2-15
Connecting the analog sensor of the voltage type
12V
i
POWER +
Sout
i
= 1, 2, 3, 4
POWER -
24V
i
ANA
i
GND
Analog
signal
sensor
Analog Sensor of the Current Type
The analog sensor of the current type has two power input ends (marked "POWER+" and
"POWER-"), as shown in
Figure 2-16
Connecting the analog sensor of the current type
POWER +
POWER -
24V
i
12V
i
ANA
i
Analog
signal
sensor
i
= 1, 2, 3, 4
2.5.8 Monitoring Port for the Relay Node Boolean Signals
This describes the monitoring port for the Boolean Sensor. The EMU supports six monitoring
ports for relay node Boolean signals, and the monitoring port for relay node Boolean signals is
suitable for a bare terminal of a cable (24 AWG - 12 AWG).
EMU
User Guide
2 Overview of the EMU
Issue 13 (2009-12-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2-17