HUAWEI UMTS M2M Module V100R001
AT Command Interface Specification
Issue 18 (2009-06-22)
Commercial in Confidence
Page 48 of 169
AT+IPR=<rate>
<CR><LF>OK<CR><LF>
<CR><LF>ERROR <CR><LF>
AT+IPR? <CR><LF>+IPR:<rate><CR><LF><CR><LF
>OK<CR><LF>
AT+IPR=?
<CR><LF>+IPR:(supported auto
detectable rates),(list of supported
fixed-only
rates) )<CR><LF><CR><LF>OK<CR><LF>
3.32.2 Description
This numeric extended-format parameter specifies the data rate at which the MT2 will
accept command set, in addition to 1200 bit/s or 9600 bit/s (as required in
EIA/TIA-602). It may be used to select operation at rates at which the MT2 is not
capable of automatically detecting the data rate being used by the TE2. 115200bps.
(Default)
3.32.3 Defined values
<rate> valid numeric values, bps
300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400
3.33
TE-TA local flow cIFC
3.33.1 command syntax
Command
Possible
response(s)
AT+IFC=[<DCE_by_DTE>[,<DT
E_by_DCE>]]
<CR><LF>OK<CR><LF>
<CR><LF>ERROR<CR><LF>
AT+IFC? <CR><LF>+IFC:<DCE_by_DTE>,<DTE_
by_DCE><CR><LF><CR><LF>OK<CR><L
F>
AT+IFC=?
<CR><LF>+ICF: (list of supported
<DCE_by_DTE>s), (list of
supported
<DTE_by_DCE>s)<CR><LF><CR><LF>O
K<CR><LF>
3.33.2 Description
The command AT+IFC can be used to set or query the data flow control for both data
directions.
Содержание EM770W
Страница 2: ......