DBS3900 V300R008
Product Description
Issue 04 (2008-06-11)
Commercial in Confidence
Page 37 of 46
Table 7-14
External alarm port on the RRU
RRU Type
Port
Quantity
Connector
RRU3004
Port providing
access of two dry
contact alarms
1
DB15 connector
7.8.6 Other External Ports on the RRU
Table 7-15 lists the other external ports on the RRU.
Table 7-15
Other external ports on the RRU
Application
Port
Quantity
Connector
Power supply
–48 V DC
2
OT
RET
communication
AISG
1
DB9
TX/RX duplexing
2
DIN type, round and
waterproof
Radio frequency
RRU RX
interconnecting
1
DB2W2
connector
7.9 Lightning Protection Specifications
The surge protection specifications are based on the surge waveform of 8/20 µs.
Unless otherwise specified, the surge current refers to a nominal discharge current.
7.9.1 Lightning Protection Specifications for the BBU
Table 7-16 lists the lightning protection specifications for the external ports on the
BBU.
Table 7-16
Lightning protection specifications for the external ports on the BBU
Application
Lightning Protection Mode
Surge Current
Differential mode
2 kA
Power supply
Common mode
4 kA
Differential mode
250 A
E1
Common mode
250 A