The NPU-50 has the 50-Gbit/s forwarding capability, and all subcards exchange data through
the NPU-50.
You can install two NPUs on the chassis of the CX600-X2-M16. The two NPUs can work in 1
+1 or 1:1 mode. In 1+1 mode, the NPU-50 is connected to the eight PICs. In 1:1 mode, the
NPU-120-E is connected to the sixteen PICs.
The NPU-50 consists of the following planes:
l
Control and management plane
Through the management channels between MPUs and NPUs, the MPUs can manage
NPUs and associated subcards, and transmit routing protocol data.
l
Data forwarding plane
The NPUs are responsible for service processing in the entire system, and are connected
to all subcards through data channels.
Table 2-12
NPU parameters
Item
Description
Remarks
Forwarding capability
50 Gbit/s
-
Figure 2-16
Appearance of the NPU panel
1. STAT indicator
2. ACT indicator
3. OFL button
describes the buttons and indicators on the NPU panel.
Table 2-13
Description of the buttons and indicators on the NPU panel
Indicator/
Button
Description
STAT
indicator
If the indicator is on, the NPU is working properly.
If the indicator blinks green, theNPU is being registered.
If the indicator is off, the NPU is faulty, not powered on, or fails to be registered.
ACT
indicator
If the indicator is steady green, the NPU is in the master state.
If the indicator is off, the NPU is in the slave state or fails to be registered.