Figure 3-17
Appearance of the Switch Fabric Unit B(SFUI-200-B)
Panel
shows the appearance of the panel.
Figure 3-18
Appearance of the panel
1. Ejector lever
2. ACT indicator
3. OFL button
4. OFL indicator
5. RUN indicator
describes the buttons and indicators on the panel.
Table 3-11
Buttons and indicators on the panel
LED
Description
RUN
(green)
Before the registration of the SFU: If the indicator blinks twice every second (2
Hz), the system is in the alarm state.
After the registration of the SFU: If the indicator blinks once every two seconds
(0.5 Hz), the system is running normally.
ACT
(green)
If the indicator is on, it indicates that the SFU is working normally; if the green
indicator is off, it indicates that the SFU is faulty.
OFL (red) When the SFU is working normally, the OFL indicator is off. After the OFL
button is pressed to power off the SFU, the OFL indicator is on.
NOTE
The Switch Fabric Unit B (SFUI-200-B) can be used only on the CX600-X16.
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description
3 CX600-X16
Issue 03 (2013-11-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
50