3.3.3 Fan Module
This section describes the appearance of the fan module.
Two fan modules, each containing one fan, are located side by side at the air exhaust vent. If a
single fan fails, the system can still work normally for a short period of time at ambient
temperature of 40ºC (104ºF).
shows the appearance of a fan module.
NOTE
Short-term operation means that the continuous working time does not exceed 96 hours and the accumulated
time per year does not exceed 15 days.
Figure 3-13
Appearance of a fan module
lists the indicators on the fan module.
Table 3-8
Description of the indicators on the fan module
Indicator
Color
Description
STATUS
Green
If the indicator blinks, the fan
module is working normally.
Red
If the indicator blinks, the fan
module, PEM, or filtering
box is faulty.
lists the technical parameters of the fan module.
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description
3 CX600-X16
Issue 03 (2013-11-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
45