The FTP server is configured.
----End
6.9 Using the CLI to Collect converged switching plane
Information
Scenarios
Use the CLI to collect the following information:
l
Logs
l
Debugging information
l
Trap information
Prerequisites
Conditions
WFTPD 4.2.4.610 or later has been installed.
wftpd32.exe
is a cross-platform tool used to
transfer files from a PC to switch modules. This tool is a piece of third-party free software.
Obtain it yourself.
Data
Table 6-2
Data list
Parameter
Example Value
IP addresses
192.168.1.100
Subnet mask
255.255.255.0
Default gateway
0.0.0.0
The default user name of a switching plane is
root
, and the default password is
Huawei12#$
.
NOTE
You can query and set IP addresses of all modules on the MM910 WebUI. For details about how to log
in to the MM910 WebUI, see
6.5 Logging In to the MM910 WebUI
.
l
For MM910 earlier than (U54) 2.20, choose
System Management
>
Network Management
>
Switch Module
>
IP Address
.
l
For MM910 (U54) 2.20 or later, choose
Chassis Settings
>
Network Settings
>
Switch Module
.
Procedure
Step 1
Log in to the Ethernet switching plane from the CLI. For details, see
MM910 CLI Over a Network Port by Using PuTTY
.
CX320 Switch Module
User Guide
6 Common Operations
Issue 09 (2019-08-02)
Copyright © Huawei Technologies Co., Ltd.
101