background image

 

Quidway® NetEngine 40E Core Router Switch and Route Processing Unit 

 

Copyright ©2007 Huawei Technologies Co., Ltd. All Rights Reserved. 

http://www.huawei.com/products/datacomm/

 

2

 

z

 

Out-band communication path among the boards of the entire system 

The SRU board integrates the LAN Switch module to provide inter-board out-band 

communication for various boards. It completes control, maintenance and message exchange 

among the SRU, SFU and Line Processing Unit (LPU).   

z

 

Equipment management and maintenance function   

z

 

Data configuration function

 

The system configuration data, boot file, charging information, upgrade software and system 

operation log are all saved on the SRU board. The SRU board provides a CF card interface as 

a mass storage device to save data files. 

 

z

 

Reliability guarantee

 

In view of reliability, the 1+1 redundant backup mode is adopted for the MPUs. The MPUs 

monitor each other’s status. Once the active MPU is faulty, the standby MPU automatically 

becomes active. 

 

2. Component of the system switching network 

Two SFU modules integrated on the SRU and two SFU boards together form four switching planes 

that implement 3+1 load sharing.   

3. System clock unit 

The SRU board provides Synchronous Digital Hierarchy (SDH) interface clock signals of high 

precision and high reliability to various line boards. It provides two 2.048MHz synchronous clock 

signals to the downstream equipment and may receive external 2.048MHz or 2.048Mbps reference 

clock. 

4. Switching synchronous clock unit

 

It ensures the synchronization of the working clocks of the switching network and various line 

boards.  

5. System maintenance unit 

This board collects the operating data of various system units via the monitoring bus, and 

generates control information according to the operating states of these units. Such control 

information concerns board in-position detection, switching network operating status control, fan 

speeding up, and so on. The 1+1 hot backup mode is adopted for the MPU, clock and LAN Switch 

modules of the board, which raises the system reliability.   

 

Specifications 

Currently, the NE40E provides one type of SRU: CR52-SRUA. The CR52-SRUA board provides 

multiple external interfaces. Its specifications and functions are described in the following table:   

Отзывы: