background image

2

 Exterior of the BTS3900 Cabinet

The BTS3900 cabinet is a vertical cabinet, which is designed in compliance with the IEC297
standard.

Figure 2-1

 shows the exterior of a BTS3900 cabinet.

Figure 2-1

 Exterior of a BTS3900 cabinet

 

Figure 2-2

 shows the dimensions of a BTS3900 cabinet.

BTS3900
Hardware Description

2 Exterior of the BTS3900 Cabinet

Issue 04 (2011-02-15)

Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

2-1

Содержание BTS3900 V100R003

Страница 1: ...BTS3900 V100R003 Hardware Description Issue 04 Date 2011 02 15 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ......

Страница 3: ...be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of this document to ensu...

Страница 4: ......

Страница 5: ...rsion BTS3900 V100R003 Intended Audience This document is intended for l System engineers l Base station installation engineers l Site maintenance engineers Organization 1 Changes in the BTS3900 Hardware Description This describes the changes in the BTS3900 Hardware Description 2 Exterior of the BTS3900 Cabinet The BTS3900 cabinet is a vertical cabinet which is designed in compliance with the IEC2...

Страница 6: ...in this document are defined as follows Symbol Description Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium or low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance ...

Страница 7: ...cted x y Optional items are grouped in braces and separated by vertical bars A minimum of one item or a maximum of all items can be selected x y Optional items are grouped in brackets and separated by vertical bars Several items or no item can be selected GUI Conventions The GUI conventions that may be found in this document are defined as follows Convention Description Boldface Buttons menus para...

Страница 8: ...rations The mouse operations that may be found in this document are defined as follows Action Description Click Select and release the primary mouse button without moving the pointer Double click Press the primary mouse button twice continuously and quickly without moving the pointer Drag Press and hold the primary mouse button and move the pointer to a certain position About This Document BTS3900...

Страница 9: ...n Principles for the CPRI Ports on the RFU in the GSM UMTS Base Station 3 31 3 5 6 Configuration Principles for the CPRI Ports on the RFU in the GSM LTE Base Station 3 33 3 5 7 Configuration Principles for the CPRI Ports on the RFU in the UMTS LTE Base Station 3 35 3 6 BTS3900 Monitoring System 3 36 3 6 1 BBU Monitoring Port 3 36 3 6 2 Monitoring Principles of the Cabinet 3 37 3 6 3 Customized Ala...

Страница 10: ...1 List of BTS3900 Cables 5 3 5 2 BTS3900 Cable Connections 5 8 5 2 1 Power Cable Connections 5 9 5 2 2 Transmission Cable Connections 5 12 5 2 3 CPRI Cable Connections 5 38 5 2 4 Monitoring Signal Cable Connections 5 50 5 2 5 RF Cable Connections 5 53 5 3 PGND Cables 5 66 5 4 Equipotential Cable 5 67 5 5 BTS3900 Power Cable 5 68 5 5 1 Input Power Cable for the Cabinet 5 68 5 5 2 Power Cable for th...

Страница 11: ...nal Cable for the Fan Box 5 83 5 8 5 Fan Box Cascade Signal Cable 5 84 5 8 6 Monitoring Signal Cable for the EMU 5 85 5 8 7 Monitoring Signal Cable for the GATM 5 86 5 8 8 BBU Alarm Cable 5 87 5 8 9 GPS Clock Signal Cable 5 89 5 8 10 Signal Cable for the ELU 5 90 5 9 BTS3900 RF Cable 5 90 5 9 1 RF Jumper 5 91 5 9 2 Inter RFU RF Signal Cable 5 91 6 BTS3900 Auxiliary Equipment 6 1 6 1 PS4890 Cabinet...

Страница 12: ......

Страница 13: ... 17 Figure 3 15 Two stacked BTS3900 AC cabinets 3 18 Figure 3 16 Power distribution of the BTS3900 48 V DC cabinet 3 20 Figure 3 17 Power distribution of the BTS3900 24 V DC cabinet 3 21 Figure 3 18 Power distribution of the BTS3900 AC cabinet 3 21 Figure 3 19 CPRI port connection principles 3 25 Figure 3 20 Configuration principles for the CPRI ports in a single cabinet 3 26 Figure 3 21 Configura...

Страница 14: ...ure 3 50 GSM S4 2 2 S4 4 4 UMTS 900M S1 1 1 3 54 Figure 3 51 GSM S4 4 4 S8 8 8 UMTS 900M S2 2 2 900M 2M 2M 2M 1800M 2G 2G 2G 3 55 Figure 3 52 3MRFU 6GRFU 3WRFU 3 56 Figure 3 53 MRFU900M 2T2R 3 x 20 MHz MRFU1800M 2T2R 3 x 20 MHz 3 57 Figure 3 54 MRFU900M 2T2R 3 x 20 MHz 6GRFU1800M 3 58 Figure 3 55 3 x 20 MHz 2T2R 3 59 Figure 3 56 3GRFU LRFU 3 x 20 MHz 3 60 Figure 3 57 MRFU900M 3 x 20 MHz 3GRFU1800M...

Страница 15: ...gure 4 35 Logical structure of the DRFU 4 46 Figure 4 36 Panel of the WRFU 4 49 Figure 4 37 Principle of the WRFU 4 50 Figure 4 38 Panel of the MRFU 4 53 Figure 4 39 Logical structure of the MRFU 4 54 Figure 4 40 Panel of the LRFU 4 57 Figure 4 41 Logical structure of the LRFU 4 58 Figure 4 42 Panel of the DCDU 01 4 61 Figure 4 43 Fan box 4 62 Figure 4 44 Ports on the FMU board 4 62 Figure 4 45 GA...

Страница 16: ...optical ports for interconnection and FE electrical ports connected to the BSC and RNC 5 21 Figure 5 23 Transmission cable connections with FE electrical ports for interconnection and FE optical ports connected to the BSC and RNC 5 21 Figure 5 24 E1 T1 cable connections in separate transmission mode 5 22 Figure 5 25 FE GE cable connections in separate transmission mode 1 5 22 Figure 5 26 FE GE cab...

Страница 17: ...5 36 Figure 5 50 Transmission cable connections in a base station in UMTS 8E1 T1 LTE FE GE mode 2 5 37 Figure 5 51 Transmission cable connections in a base station in UMTS FE GE LTE FE GE mode 1 5 37 Figure 5 52 Transmission cable connections in a base station in UMTS FE GE LTE FE GE mode 2 5 38 Figure 5 53 Star topology 5 39 Figure 5 54 Chain topology 5 39 Figure 5 55 Star topology over CPRI port...

Страница 18: ...92 Equipotential cable 5 67 Figure 5 93 48 V power cable 5 68 Figure 5 94 24 V power cable 5 69 Figure 5 95 AC power cable 220 V AC single phase 5 70 Figure 5 96 Power cable for the DCDU 01 5 71 Figure 5 97 Power cable for the BBU 5 71 Figure 5 98 Power cable for the fan box 5 72 Figure 5 99 Power cable for the RFU 5 73 Figure 5 100 Power cable for the GATM 5 74 Figure 5 101 E1 T1 cable 5 75 Figur...

Страница 19: ...8 Signal cable for the ELU 5 90 Figure 5 119 RF jumper 5 91 Figure 5 120 Inter RFU RF signal cable 5 91 Figure 6 1 Cable connections between the BTS3900 and the PS4890 6 2 Figure 6 2 Structure of the DDF 6 3 BTS3900 Hardware Description Figures Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd xvii ...

Страница 20: ......

Страница 21: ...the two cabinets 3 27 Table 3 16 Configuration principles for the CPRI ports in cabinet 2 of the two cabinets 3 27 Table 3 17 CPRI port configuration principles 1 3 29 Table 3 18 CPRI port configuration principles 2 3 29 Table 3 19 CPRI port configuration principles 3 30 Table 3 20 Configuration principles for the CPRI ports on the MRFUs 1 3 32 Table 3 21 Configuration principles for the CPRI port...

Страница 22: ...Ds and their status 4 12 Table 4 10 Ports on the WMPT panel 4 12 Table 4 11 Settings of SW1 4 13 Table 4 12 Settings of SW2 4 14 Table 4 13 LEDs on the panel of the LMPT 4 15 Table 4 14 Ports and LEDs 4 16 Table 4 15 Ports on the panel of the LMPT 4 17 Table 4 16 Specifications of the WBBP 4 18 Table 4 17 LEDs on the WBBP and their status 4 19 Table 4 18 LEDs indicating the status of the SFP links...

Страница 23: ...ts on the panel of the MRFU 4 56 Table 4 54 LEDs on the LRFU 4 59 Table 4 55 Ports on the panel of the LRFU 4 60 Table 4 56 Ports terminals and power switches on the panel of the DCDU 01 4 61 Table 4 57 LEDs on the FMU board 4 63 Table 4 58 Ports on the FMU board 4 63 Table 4 59 LEDs on the GATM 4 64 Table 4 60 Ports and socket on the GATM 4 65 Table 4 61 Components of the power equipment DC DC 4 ...

Страница 24: ... FE optical ports for interconnection and FE electrical ports connected to the BSC and RNC 5 21 Table 5 28 Transmission cables with FE electrical ports for interconnection and FE optical ports connected to the BSC and RNC 5 22 Table 5 29 E1 T1 cable connections in separate transmission mode 5 22 Table 5 30 FE GE cable connections in separate transmission mode 1 5 23 Table 5 31 FE GE cable connecti...

Страница 25: ...in UMTS 8E1 T1 LTE FE GE mode 2 5 37 Table 5 56 Transmission cable connections in a base station in UMTS FE GE LTE FE GE mode 1 5 38 Table 5 57 Transmission cable connections in a base station in UMTS FE GE LTE FE GE mode 2 5 38 Table 5 58 Monitoring signal cable connections of the BTS3900 48 V DC 5 51 Table 5 59 Monitoring signal cable connections of the BTS3900 24 V DC 5 52 Table 5 60 Signal cab...

Страница 26: ...BBU alarm cable 5 88 Table 5 80 Pin assignment for the wires of the signal cable for the ELU 5 90 Table 6 1 Cables between the BTS3900 and the PS4890 6 2 Table 6 2 Technical specifications of the DDF 6 4 Tables BTS3900 Hardware Description xxiv Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 27: ...e BBU3900 The configuration restriction is modified Compared with issue 03 2010 10 25 no information is deleted 03 2010 10 25 This is the second commercial release Compared with issue 02 2010 08 30 no topic is added Compared with issue 02 2010 08 30 this issue incorporates the following change Contents Change Description 2 Exterior of the BTS3900 Cabinet The dimensions of the BTS3900 cabinet is ad...

Страница 28: ...Base Station l RF Configurations l CPRI Cable Connections in the LTE Only Base Station l CPRI Cable Connections in the GSM LTE Base Station l CPRI Cable Connections in the UMTS LTE Base Station Compared with issue 01 2010 05 04 the following part is modified Part Modification 3 5 1 CPRI Port Specifications LBBPb LBBPc and LRFU are added Compared with issue 01 2010 05 04 no information is deleted 0...

Страница 29: ...EC297 standard Figure 2 1 shows the exterior of a BTS3900 cabinet Figure 2 1 Exterior of a BTS3900 cabinet Figure 2 2 shows the dimensions of a BTS3900 cabinet BTS3900 Hardware Description 2 Exterior of the BTS3900 Cabinet Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 2 1 ...

Страница 30: ...Figure 2 2 Dimensions of a BTS3900 cabinet 2 Exterior of the BTS3900 Cabinet BTS3900 Hardware Description 2 2 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 31: ...lied the power is converted to 48 V DC power for the base station 3 4 Transmission Board Configurations In different modes different transmission boards can be configured for E1 T1 or FE signal transmission 3 5 CPRI Port Configurations This section describes the specifications and cable connections of the CPRI ports on boards and modules 3 6 BTS3900 Monitoring System The BTS3900 monitoring system ...

Страница 32: ...erred to as LO GSM UMTS hereinafter referred to as GU GSM LTE hereinafter referred to as GL and UMTS LTE hereinafter referred to as UL scenarios 3 1 1 Module Configurations in the Cabinet The BTS3900 cabinet uses a modular design The main components of the cabinet are the BBU3900 RFU DCDU 01 and fan box The power equipment DC DC and power equipment AC DC are optional components of the cabinet The ...

Страница 33: ...t 4 BBU3900 5 DCDU 01 6 Power equipment DC DC Figure 3 3 Module configurations in the BTS3900 cabinet AC 1 RFU 2 Fan box 3 Air inlet BTS3900 Hardware Description 3 BTS3900 Hardware Configuration Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 3 3 ...

Страница 34: ...the heat in the cabinet BBU3900 Optional 1 The BBU3900 processes the baseband signals and enables interaction between the base station and the base station controller DCDU 01 Mandatory 1 The DCDU 01 provides DC power to all components in the cabinet Power equipment DC DC Optional 1 The power equipment DC DC converts external 24 V DC power into 48 V DC power and provides power to all components in ...

Страница 35: ...ions of the BBU3900 in the GSM Only hereinafter referred to as GO UMTS Only hereinafter referred to as UO LTE Only hereinafter referred to as LO GSM UMTS hereinafter referred to as GU GSM LTE hereinafter referred to as GL and UMTS LTE hereinafter referred to as UL scenarios Slots in the BBU3900 The board configurations of the BBU3900 in GO mode BBU3900 in GU mode BBU3900 in UO mode BBU3900 in LO m...

Страница 36: ...EU USCU Optional 1 Slot 0 or slot 1 Preferentially configured in slot 1 Configured in slot 1 in the case of 1 U dual satellite card in this case slot 0 is also occupied UEIU Optional 1 Slot 18 Figure 3 5 shows the typical configurations of the BBU3900 in GO mode Figure 3 5 Typical configuration of the BBU3900 in GO mode BBU3900 in UO Mode Table 3 3 describes the principles for configuring the boar...

Страница 37: ...l If an expansion of the CPRI port is not required configure the board in a slot with slot priority of slot 0 slot 1 and slot 2 FAN Mandatory 1 Slot 16 Configured only in slot 16 UPEU Mandatory 2 Slot 18 or slot 19 Preferentially configured in slot 19 in the case of a single UPEU UEIU Optional 1 Slot 18 UTRP Optional 4 Slot 0 slot 1 slot 4 and slot 5 Configured in a slot with slot priority of slot...

Страница 38: ...able 3 4 describes the principles for configuring the boards in the BBU3900 in LO mode Table 3 4 Principles for configuring the boards in the BBU3900 in LO mode Board Optional Mandatory Maximum Quantity Slot Remarks LMPT Mandatory 2 Slot 6 or slot 7 Configured only in slot 7 in the case of a single LMPT LBBP Mandatory 3 Slots 0 to 3 Configured in a slot with slot priority of slot 3 slot 1 and slot...

Страница 39: ...ed in slot 5 in the case of a single USCU configured in slot 5 in the case of 1 U USCU in this case slot 4 is also occupied Preferentially configured in slot 1 if slot 4 and slot 5 are occupied configured in slot 1 in the case of 1 U USCU in this case slot 0 is also occupied Figure 3 7 shows the typical configurations of the BBU3900 in LO mode Figure 3 7 Typical configuration of the BBU3900 in LO ...

Страница 40: ... slot priority of slot 3 slot 0 slot 1 and slot 2 FAN Mandatory 1 Slot 16 Configured only in slot 16 UPEU Mandatory 2 Slot 18 or slot 19 Configured only in slot 19 in the case of a single UPEU UEIU Optional 1 Slot 18 UTRP Optional 2 Slot 0 slot 1 or slot 4 Configured in a slot with slot priority of slot 4 slot 0 and slot 1 USCU Optional 1 Slot 0 or slot 1 Preferentially configured in slot 1 Config...

Страница 41: ...rds in the BBU3900 in GL mode Table 3 6 Principles for configuring the boards in the BBU3900 in GL mode Board Optional Mandatory Maximum Quantity Slot Remarks LMPT Mandatory 1 Slot 7 Configured only in slot 7 GTMU Mandatory 1 Slots 5 and 6 Configured only in slot 6 both slots 5 and 6 are occupied LBBP Mandatory 3 Slots 0 to 3 Configured in a slot with slot priority of slot 3 slot 1 and slot 2 FAN ...

Страница 42: ...Slot 0 or slot 1 Preferentially configured in slot 1 Configured in slot 1 in the case of 1 U dual satellite card in this case slot 0 is also occupied UBRI Optional 1 Slot 2 For V100R003C01 the UBRI can be installed in slot 1 or 2 and it is preferrentially installed in slot 2 Figure 3 9 shows the typical configurations of the BBU3900 in GL mode Figure 3 9 Typical configuration of the BBU3900 in GL ...

Страница 43: ...y 3 Slot 0 slot 1 or slot 3 Configured in a slot with slot priority of slot 3 slot 0 and slot 1 in the case of a single WBBP FAN Mandatory 1 Slot 16 Configured only in slot 16 UPEU Mandatory 2 Slot 18 or slot 19 Configured only in slot 19 in the case of a single UPEU UEIU Optional 1 Slot 18 UTRP Optional 2 Slot 0 slot 1 slot 4 or slot 5 Configured in a slot with slot priority of slot 4 slot 5 slot...

Страница 44: ...inciples for installing two cabinets side by side are as follows l By default the primary cabinet is positioned on the left and the secondary cabinet is positioned on the right If restricted by the actual situation in the equipment room the primary cabinet can be positioned on the right l The BTS3900 48 V DC cabinet BTS3900 24 V DC cabinet and BTS3900 AC cabinet support side by side installation m...

Страница 45: ...stalled side by side Figure 3 12 Two BTS3900 24 V DC cabinets installed side by side BTS3900 Hardware Description 3 BTS3900 Hardware Configuration Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 3 15 ...

Страница 46: ...an be stacked l The BTS3900 24 V DC cabinets cannot be stacked l The stacking of the BTS3900 AC cabinets is not recommended If cabinets are stacked the highest operating temperature of the cabinets is 50 C Figure 3 14 and Figure 3 15 show the stack mode with two cabinets 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 16 Huawei Proprietary and Confidential Copyright Huawei Technolo...

Страница 47: ...ure 3 14 Two stacked BTS3900 48 V DC cabinets BTS3900 Hardware Description 3 BTS3900 Hardware Configuration Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 3 17 ...

Страница 48: ... the base station Table 3 8 and Table 3 9 list the input voltage ranges supported by the BTS3900 Table 3 8 Applicable AC input voltage ranges Power Input Type Rated Voltage Working Voltage 220 V AC single phase 220 V AC to 240 V AC 176 V AC to 290 V AC 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 18 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 0...

Страница 49: ...tions of the Upper Level Circuit Breaker and Power Cables This section describes the recommended configurations of the upper level circuit breaker and power cables for the BTS3900 The recommended configurations are based on a fully configured single cabinet which has the peak output power The power requirements for the customer equipment in the cabinet are also included Table 3 10 lists the recomm...

Страница 50: ...0 This section describes the power distribution modes of the BTS3900 Power Distribution of the BTS3900 48 V DC Cabinet The external power equipment supplies 48 V DC power to the DCDU 01 of the BTS3900 48 V DC cabinet and the DCDU 01 feeds power to each module in the BTS3900 cabinet Figure 3 16 shows the power distribution principles Figure 3 16 Power distribution of the BTS3900 48 V DC cabinet NOT...

Страница 51: ...DC cabinet Power Distribution of the BTS3900 AC Cabinet The external power equipment supplies 220 V AC single phase or three phase power or 110 V AC dual live wire power to the BTS3900 AC cabinet The power equipment AC DC converts the AC power into 48 V DC power and feeds the 48 V DC power to the DCDU 01 The DCDU 01 feeds power to each module in the cabinet Figure 3 18 shows the power distribution...

Страница 52: ...annels UTRP4 UMTS 2 Eight channels UTRPb4 LTE 2 Eight channels TDM over E1 T1 GTMU GTMUb GSM 1 Four channels UTRPb4 GSM 1 Four channels Transmission over FE GE optical cable GTMU GTMUb GSM 1 10 Mbit s and 100 Mbit s LMPT LTE 2 10 Mbit s 100 Mbit s and 1000 Mbit s WMPT UMTS 1 10 Mbit s and 100 Mbit s UTRP2 UMTS 2 10 Mbit s 100 Mbit s and 1000 Mbit s Transmission over FE GE electrical cable GTMU GTM...

Страница 53: ...U 3 5 3 Configuration Principles for the CPRI Ports on the RFU in the UMTS Only Base Station When a base station works in UMTS mode the WRFUs in the slots of the cabinet are connected to the WBBPbs WBBPds in the BBU 3 5 4 Configuration Principles for the CPRI Ports on the RFU in the LTE Only Base Station When a base station works in LTE only mode the RFUs in the cabinet are the LRFUs 3 5 5 Configu...

Страница 54: ...t s Star chain or ring LBBPb 6 1 25 Gbit s or 2 5 Gbit s or 4 9 Gbit s Star chain or ring LBBPc 6 1 25 Gbit s or 2 5 Gbit s or 4 9 Gbit s Star chain or ring Specifications of the CPRI Ports on the RFUs Table 3 13 lists the specifications of the CPRI ports on the RFUs Table 3 13 Specifications of the CPRI ports on the RFUs RFU Number of CRPI Ports Transmission Rate of the CPRI Port Supported Topolo...

Страница 55: ...ading The data transmission rates over the CPRI ports of the cascaded DRFUs GRFUs are the same l The DRFUs GRFUs cannot be connected to the RRU Figure 3 19 shows the CPRI connection principles Figure 3 19 CPRI port connection principles CPRI Port Configuration Principles l Each CPRI port on the GTMU corresponds to a sector l The CRPI1 port on the DRFU is connected to the GTMU and the CPRI0 port is...

Страница 56: ...1 2 3 4 5 Number of the CPRI Port on the GTMU CPRI0 CPRI1 CPRI2 CPRI3 CPRI4 CPRI5 l The CPRI port configuration principles in a base station with two cabinets are shown in Figure 3 21 and listed in Table 3 15 and Table 3 16 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 26 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 57: ...orts in cabinet 2 of the two cabinets Slot Number of the DRFU GRFU 0 and 1 2 and 3 4 and 5 Number of the CPRI Port on the GTMU CPRI1 CPRI3 CPRI5 3 5 3 Configuration Principles for the CPRI Ports on the RFU in the UMTS Only Base Station When a base station works in UMTS mode the WRFUs in the slots of the cabinet are connected to the WBBPbs WBBPds in the BBU BTS3900 Hardware Description 3 BTS3900 Ha...

Страница 58: ...les Figure 3 22 CPRI port connection principles CPRI Port Configuration Principles l Each CPRI port on the WBBPb WBBPd corresponds to a sector l The CRPI0 port on the WRFU is connected to the WBBP and the CPRI1 port is connected to the lower level WRFU l The CPRI port configuration principles in a base station configured with WBBPbs are shown in Figure 3 23 and listed in Table 3 17 Figure 3 23 CPR...

Страница 59: ...onfiguration principles 2 Table 3 18 CPRI port configuration principles 2 MRFU Slot Number 0 1 2 3 4 5 Number of the WBBPd in Slot3 CPRI0 CPRI2 CPRI4 3 5 4 Configuration Principles for the CPRI Ports on the RFU in the LTE Only Base Station When a base station works in LTE only mode the RFUs in the cabinet are the LRFUs BTS3900 Hardware Description 3 BTS3900 Hardware Configuration Issue 04 2011 02 ...

Страница 60: ... Port Configuration Principles l The CPRI0 port on the LRFU is connected to the LBBP The CPRI port configuration principles are shown in Figure 3 26 and listed in Table 3 19 Figure 3 26 CPRI port configuration principles Table 3 19 CPRI port configuration principles LRFU Slot Number 0 1 2 3 4 5 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 30 Huawei Proprietary and Confidential C...

Страница 61: ... CPRI port connection principles for the MRFUs working in GSM UMTS mode Figure 3 27 CPRI port connection principles CPRI Port Configuration Principles In co cabinet mode the CPRI port configuration principles of the DRFUs GRFUs and WRFUs follow the configuration principles in GSM and UMTS modes respectively In co module mode the CPRI port configuration principles are as follows l The CPRI0 port on...

Страница 62: ...1 MRFU Slot Number 0 1 2 3 4 5 Number of the CPRI Port on the GTMU CPRI0 CPRI1 CPRI2 CPRI3 CPRI4 CPRI5 Number of the WBBPb in Slot3 CPRI0 CPRI1 CPRI2 Number of the WBBPb in Slot2 CPRI0 CPRI1 CPRI2 The CPRI port configuration principles in a base station configured with WBBPds are shown in Figure 3 29 and listed in Table 3 21 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 32 Huawei...

Страница 63: ...E mode the RFUs in the cabinet are the MRFUs and the boards configured in the BBU are the GTMU UBRI LMPT and LBBP Basic CPRI Port Connection Principles l The MRFUs can work in the dual star topology rather than chain topology l When the MRFU works in the dual star topology the signals in the same mode cannot be transmitted over two CPRI links l MRFUs cannot be connected to RRUs Figure 3 30 shows t...

Страница 64: ...the GTMU or UBRI for GSM data transmission l The CPRI1 port on the MRFU is connected to the LBBP for LTE data transmission The CPRI port configuration principles are shown in Figure 3 31 and listed in Table 3 22 Figure 3 31 Configuration principles for the CPRI ports on the MRFUs Table 3 22 Configuration principles for the CPRI ports on the MRFUs MRFU Slot Number 0 1 2 3 4 5 3 BTS3900 Hardware Con...

Страница 65: ...T WBBP LMPT and LBBP CPRI Port Configuration Principles The UMTS LTE base station works in co cabinet mode l The WRFUs use the configuration principles for the CPRI ports on RFUs in UMTS mode l The LRFUs use the configuration principles for the CPRI ports on RFUs in LTE mode The CPRI port connection principles in UMTS LTE mode are shown in Figure 3 32 and listed in Table 3 23 Figure 3 32 CPRI port...

Страница 66: ...he Cabinet The BTS3900 cabinet is managed by the monitoring boards such as the FMU and PMU A monitoring board is connected to the MON port on the BBU It collects the alarms of all components and reports the alarms to the BBU by using the RS485 serial bus 3 6 3 Customized Alarm Inputs When an alarm is generated by the customized equipment the alarm must be reported to the BBU 3 6 1 BBU Monitoring P...

Страница 67: ...5 connector 1 Port for Boolean inputs 0 to 3 EXT ALM1 RJ 45 connector 1 Port for Boolean inputs 4 to 7 MON0 RJ 45 connector 1 Port for RS485 input 0 MON1 RJ 45 connector 1 Port for RS485 input 1 3 6 2 Monitoring Principles of the Cabinet The BTS3900 cabinet is managed by the monitoring boards such as the FMU and PMU A monitoring board is connected to the MON port on the BBU It collects the alarms ...

Страница 68: ...in the BTS3900 cabinet AC For details about the position of the PMU in the cabinet see 3 1 1 Module Configurations in the Cabinet This document describes monitoring principles of two BTS3900 cabinets If cabinet 1 is not configured the monitoring cables connected to the cabinet are not required Figure 3 34 Monitoring system for the BTS3900 cabinet 48 V DC Figure 3 35 Monitoring system for the BTS39...

Страница 69: ...ils about the configuration of the customized alarms see the related initial configuration guide Monitoring Board Configuration The configuration of the monitoring boards in the BTS3900 depends on the number of customized alarms as listed in Table 3 25 Table 3 25 Configuration of monitoring boards in the BTS3900 Cabinet Type Number of Dry Contact Alarm Inputs Monitoring Board 48 V DC cabinet or AC...

Страница 70: ...6 Boolean alarm inputs This method can be used for the configuration of fewer than 16 customized alarm inputs The method to collect customized alarms by using the UPEU or UEIU is shown in Figure 3 37 Figure 3 37 Customized alarms collected by the UPEU or UEIU Customized Alarms Collected by the EMU If there are more than 16 Boolean alarm inputs the EMU can be configured for the BTS3900 Each EMU sup...

Страница 71: ...UMTS only mode the WRFU slot assignment in a cabinet must comply with specific principles 3 7 4 Slot Assignment for the RFUs in a Base Station Working in LTE Only Mode When a base station works in LTE only mode the LRFU or MRFU slot assignment in a cabinet must comply with specific principles 3 7 5 Slot Assignment for the RFUs in a Base Station Working in GSM UMTS Mode When a base station works in...

Страница 72: ...GRFU l 1T2R MRFU V1 MRFU V2 PGSM 900 MHz DRFU GRFU MRFU V1 MRFU V2 GSM 1800 MHz DRFU GRFU MRFU V1 MRFU V2 GSM 1900 MHz GRFU MRFU V1 UMTS only UO 850 MHz WRFU l 2 or 4 carriers WRFU l 4 carriers MRFU V1 MRFU V2 l 1T2R WRFU l 1T2R MRFU V1 MRFU V2 900 MHz MRFU V1 MRFU V2 2100 MHz WRFU LTE only LO AWS LRFU l 1 carrier LRFU l 1 carrier MRFU V2 l 2T2R LRFU l 1T2R MRFU 2600 MHz 900 MHz MRFU V2 1800 MHz G...

Страница 73: ...s used to separate 900 MHz band from 1800 MHz band in a dual band base station The GSM S4 4 4 S4 4 4 configuration indicates a base station works in dual band mode on the GSM side S2 2 2 1G 1G 1G indicates that a base station in S2 2 2 configuration is configured with one GRFU in each sector GRFU is represented by G Numbering Scheme l The sectors in a base station working in GSM only mode are numb...

Страница 74: ... If more than two GRFUs or DRFUs are configured for G3 the GRFU or DRFU that is not inserted can be preferentially positioned in slot 3 in cabinet 1 Table 3 27 Slot assignment for GRFUs or DRFUs Sector Number G1 G2 G3 Cabinet 1 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 Figure 3 39 GSM S4 4 4 1G 1G 1G Figure 3 40 GSM S10 10 8 2G 2G 2G If more than three single band sectors are configured in a single RFC ...

Страница 75: ...e than three sectors for each band with the configuration of GRFUs or DRFUs in two RFCs If not more than three sectors are configured for each band cabinet 1 is used for the band for which more GRFUs or DRFUs are configured Cabinet 2 is used for the other band If the same number of GRFUs or DRFUs are configured for each band cabinet 1 is preferentially used for 900 MHz Table 3 29 Slot assignment f...

Страница 76: ...8 3 7 3 Slot Assignment for the RFUs in a Base Station Working in UMTS Only Mode When a base station works in UMTS only mode the WRFU slot assignment in a cabinet must comply with specific principles Numbering Scheme l The sectors in a base station working in UMTS only mode are numbered from U1 in a numerical order for example U1 and U2 l The slots are numbered from 0 in a numerical order for exam...

Страница 77: ... positioned in the slots from left to right in cabinet 1 Figure 3 44 UMTS S4 4 4 2W 2W 2W 3 7 4 Slot Assignment for the RFUs in a Base Station Working in LTE Only Mode When a base station works in LTE only mode the LRFU or MRFU slot assignment in a cabinet must comply with specific principles BTS3900 Hardware Description 3 BTS3900 Hardware Configuration Issue 04 2011 02 15 Huawei Proprietary and C...

Страница 78: ...d then slot 3 if slot 2 is occupied The LRFU configured for L3 is preferentially positioned in slot 4 and then slot 5 if slot 4 is occupied l When MRFUs are configured they are preferentially positioned in the slots in cabinet 1 That is the MRFU configured for L1 is preferentially positioned in slot 0 and then slot 1 if slot 0 is occupied The MRFU configured for L2 is preferentially positioned in ...

Страница 79: ... then slot 3 if slot 2 is occupied The LRFU configured for L3 is preferentially positioned in slot 4 and then slot 5 if slot 4 is occupied MRFUs are preferentially positioned in the slots in cabinet 1 The MRFU configured for L1 is preferentially positioned in slot 0 and then slot 1 if slot 0 is occupied The MRFU configured for L2 is preferentially positioned in slot 2 and then slot 3 if slot 2 is ...

Страница 80: ...ific principles Precautions for RFU Slot Assignment l The 3900 series macro base station of SRAN5 0 supports the configurations of MRFUs hybrid configurations of GRFUs and MRFUs and hybrid configurations of GRFUs and WRFUs Hybrid configurations are used only for capacity expansion The base station with the hybrid configurations of GRFUs and MRFUs does not support MIMO l In a base station the RFUs ...

Страница 81: ...n a base station working in UMTS only mode are numbered from U1 in a numerical order for example U1 and U2 l The sectors in a multi mode base station are numbered from M1 in a numerical order for example M1 and M2 Low frequency sectors are numbered from M1 to M6 and high frequency sectors are numbered from M7 to M12 l The slots are numbered from 0 in a numerical order for example slot 0 slot 1 and...

Страница 82: ...han six GSM GRFUs or DRFUs are configured the GRFUs or DRFUs are evenly positioned in the slots in cabinet 1 By default WRFUs are positioned in slots 1 3 and 5 in cabinet 2 Table 3 33 Slot assignment for GRFUs or DRFUs and WRFUs Secto r Num ber G1 G2 G3 G7 G8 G9 U1 U2 U3 Cabin et 1 Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Cabin et 2 Slot 1 Slot 3 Slot 5 3 BTS3900 Hardware Configuration BTS3900 Ha...

Страница 83: ...configured with MRFUs in dual band mode Low frequency MRFUs are positioned in slots 0 2 and 4 in cabinet 1 and high frequency MRFUs are positioned in slots 1 3 and 5 in cabinet 1 Table 3 34 RFU slot assignment for MRFUs Sector Number M1 M2 M3 M7 M8 M9 Cabinet 1 Slot 0 Slot 2 Slot 4 Slot 1 Slot 3 Slot 5 Cabinet 2 BTS3900 Hardware Description 3 BTS3900 Hardware Configuration Issue 04 2011 02 15 Huaw...

Страница 84: ...rately MRFUs are positioned in the slots in cabinet 1 and GRFUs or DRFUs are positioned in the slots in cabinet 2 Table 3 35 RFU slot assignment for GRFUs or DRFUs and MRFUs Sector Number M1 M2 M3 G7 G8 G9 Cabinet 1 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 Cabinet 2 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 54 Huawei Proprietary and Confidential...

Страница 85: ...s or DRFUs and WRFUs MRFUs and WRFUs are preferentially positioned in the slots in cabinet 1 GRFUs or DRFUs are preferentially positioned in the slots in cabinet 2 Table 3 36 RFU slot assignment for MRFUs GRFUs or DRFUs and WRFUs Secto r Num ber M1 U1 M2 U2 M3 U3 G1 G2 G3 Cabin et 1 Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Cabin et 2 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 BTS3900 Hardware Descriptio...

Страница 86: ...s of MRFUs and LRFUs Hybrid configurations are used only for capacity expansion The base station with the hybrid configurations of GRFUs and MRFUs does not support MIMO l In a base station the RFUs in the same frequency band must be of the same type Numbering Scheme l The sectors in a base station working in GSM only mode are numbered from G1 in a numerical order for example G1 and G2 Low frequenc...

Страница 87: ...ot can be identified through cabinet number slot number for example slot 1 in cabinet 1 primary RFC Principles for RFU Slot Assignment Scenario 1 A dual band base station with the configuration of MRFUs for each band Table 3 37 Slot assignment for MRFUs in a dual band base station Sector Number M1 M2 M3 M7 M8 M9 Cabinet 1 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 Cabinet 2 Slot 0 or 1 Slot 2 or 3 Slot 4...

Страница 88: ...ure 3 54 MRFU900M 2T2R 3 x 20 MHz 6GRFU1800M Scenario 3 A dual band base station with the configuration of MRFUs and LRFUs Table 3 39 Slot assignment for MRFUs and LRFUs in a dual band base station Sector Number M1 M2 M3 L1 L2 L3 Cabinet 1 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 Cabinet 2 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 58 Huawei Prop...

Страница 89: ...t for DRFUs or GRFUs and LRFUs in a dual band base station Sector Number G1 G2 G3 L1 L2 L3 Cabinet 1 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 Cabinet 2 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 BTS3900 Hardware Description 3 BTS3900 Hardware Configuration Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 3 59 ...

Страница 90: ...RFUs GRFUs and LRFUs in a tri band base station Secto r Num ber M1 M2 M3 G7 G8 G9 L1 L2 L3 Cabin et 1 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 Cabin et 2 Slot 0 Slot 2 Slot 4 Slot 1 Slot 3 Slot 5 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 60 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 91: ... U2 l The sectors in a base station working in LTE only mode are numbered from L1 in a numerical order for example L1 and L2 l The slots are numbered from 0 in a numerical order for example slot 0 slot 1 and slot 2 A slot can be identified through cabinet number slot number for example slot 1 in cabinet 1 primary RFC Principles for RFU Slot Assignment Scenario 1 A dual mode base station with the c...

Страница 92: ...U3 Cabinet 1 Slot 0 or 1 Slot 2 or 3 Slot 4 or 5 Cabinet 2 Slot 1 Slot 3 Slot 5 Figure 3 58 UMTS S1 1 1 LTE 3 x 20 MHz 3 BTS3900 Hardware Configuration BTS3900 Hardware Description 3 62 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 93: ...FU supports 6 carriers 4 3 DRFU The Double Radio Frequency Unit DRFU is a dual density RF unit A DRFU processes two carriers 4 4 WRFU One WCDMA Radio Filter Unit WRFU supports 2 carriers or 4 carriers 4 5 MRFU One Multi Mode Radio Frequency Unit MRFU supports a maximum of six carriers 4 6 LRFU LTE Radio Frequency Units LRFUs work in Frequency Division Duplex FDD mode 4 7 DCDU 01 The Direct Current...

Страница 94: ...The power equipment DC DC converts 24 V DC power into 48 V DC power 4 12 Power Equipment AC DC The power equipment AC DC converts 220 V AC power into 48 V DC power 4 BTS3900 Components BTS3900 Hardware Description 4 2 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 95: ...erior of the BBU3900 The BBU3900 which has a case structure is 19 inches wide and 2 U high 4 1 2 Boards and Module of the BBU3900 This describes the boards and module of the BBU3900 in terms of their configuration principles functions ports LEDs and DIP switches 4 1 1 Exterior of the BBU3900 The BBU3900 which has a case structure is 19 inches wide and 2 U high The dimensions W x D x H of the BBU39...

Страница 96: ...and DIP switches GTMU The GSM Transmission Timing Management Unit for BBU GTMU is the basic transmission and control function entity of the BBU It provides the reference clock maintenance port and external alarm collection port monitors the power supply and controls and manages the entire base station Panel The GTMU is classified into two types GTMU and GTMUb Figure 4 4 and Figure 4 5 show the pan...

Страница 97: ... clock source of the base station in centralized mode l Provides the clock output for test l Provides the FE port for maintenance on the OM system l Supports transmission through four E1s and two FEs l Provides CPRI ports for communication between the BBU and the RFUs l The GTMUb supports interconnected BBUs l Four IDX2 ports on the backplane of the GTMUb can achieve the function of baseband resou...

Страница 98: ...nection status of the FE optical port FE electrical port CPRI port and commissioning port Each of the LEDs is positioned near the relevant port without any label on the panel of the board Table 4 2 describes the LEDs and their status Table 4 2 LEDs and their status LED Color Status Description LIU0 to LIU3 Green ON The link is in the idle state ON for 0 125s and OFF for 0 125s An E1 T1 remote alar...

Страница 99: ...ction is set up Green ACT LED on the right Blinking Data is being transmitted OFF No data is being transmitted M_S GTMUb This is the LED of the reserved port EXT GTMUb This is the LED of the reserved port Ports Table 4 3 describes the ports on the GTMU Table 4 3 Ports on the GTMU Label Connector Description CPRI0 to CPRI5 SFP female Data transmission port interconnected to the RFU It supports the ...

Страница 100: ...has four bits DIP switches S1 and S2 must be set together The functions of the five DIP switches are as follows l S1 is used to select the E1 resistance Table 4 4 provides details on the DIP switch l S2 is used to select the grounding mode of E1 T1 cables Table 4 5 provides details on the DIP switch l S3 is reserved l S4 is used to select the E1 bypass Table 4 6 provides details on the DIP switch ...

Страница 101: ...o rectify the faults on the E1 links Others Unavailable Table 4 6 Details of the DIP Switch S4 DIP Switch Bit Status Description 1 2 3 4 S4 ON ON ON ON Supporting E1 bypass OFF OFF OFF OFF Not supporting E1 bypass Others Unavailable Table 4 7 Details of the DIP Switch S5 DIP Switch Bit Status Description 1 2 3 4 S5 ON ON ON ON Not supporting E1 bypass OFF ON ON OFF Supporting E1 bypass of level 1 ...

Страница 102: ... has the following functions l Provides Operation and Maintenance OM functions such as configuration management equipment management performance monitoring signaling processing and active standby switchover and provides OM channels connected to the OMC LMT or M2000 l Provides the reference clock l Processes signaling and manages resources for other boards in the BBU3900 l Provides USB ports one of...

Страница 103: ...n hardware ACT Green ON The board is in active mode OFF The board is in standby mode In addition to the previous three LEDs the WMPT has another six LEDs indicating the connection status of the FE optical port FE electrical port and the commissioning Ethernet port The six LEDs have no silk screen and are on both sides of each of the three ports Figure 4 7 shows the LEDs beside the three ports Figu...

Страница 104: ...oing OFF No data transmission is ongoing ETH Green LINK ON The connections are functional OFF The connections are faulty Yellow ACT Blinking Data transmission is ongoing OFF No data transmission is ongoing Ports Table 4 10 describes the ports on the WMPT panel Table 4 10 Ports on the WMPT panel Label Connector Type Description E1 T1 DB26 connector E1 T1 port FE0 RJ45 connector FE electrical port F...

Страница 105: ...rounding for the E1 T1 cables receiving 4 way signals Figure 4 8 shows the DIP switches on the WMPT Figure 4 8 DIP switches on the WMPT Table 4 11 and Table 4 12 describe the settings of SW1 and SW2 Table 4 11 Settings of SW1 DIP Switch DIP Status Description 1 2 3 4 SW1 ON ON OFF OFF T1 Mode OFF OFF ON ON The E1 impedance is set to 120 ohms BTS3900 Hardware Description 4 BTS3900 Components Issue ...

Страница 106: ...fault When four E1 links are faulty you should set all the DIP bits of SW2 to ON so that the faults are rectified LMPT The LTE Main Processing Transmission unit LMPT manages the entire eNodeB system in terms of OM and signaling processing and provides the clock for the BBU3900 Panel Figure 4 9 shows the LMPT Figure 4 9 LMPT TX SFP 0 RX TX SFP 1 RX USB TST ETH FE GE0 FE GE1 GPS RST RUN ALM ACT LMPT...

Страница 107: ...faulty Blinking on for 1s and off for 1s The board is running properly Blinking on for 0 125s and off for 0 125s The board is being loaded the board is not started or the board is running properly ALM Red On An alarm is reported indicating a fault in the board Off The board is working properly Blinking on for 1s and off for 1s An alarm is generated and the alarm may be caused by an associated boar...

Страница 108: ...ts and LEDs Label Color Status Description SFP0 and SFP1 Green LINK On The connection is set up successfully Off No connection is set up Orange ACT Blinking Data is being transmitted Off No data is being transmitted ETH Orange ACT Blinking Data is being transmitted Off No data is being transmitted Green LINK On The connection is set up successfully Off No connection is set up FE GE0 to FE GE1 Gree...

Страница 109: ...y equipment GPS SMA 1 Receiving GPS signals RST 1 Resetting the BBU3900 NOTE SFP0 and FE GE0 ports on the LMPT are used for one GE input Therefore they are not used simultaneously SFP1 and FE GE1 ports on the LMPT are used for another GE input Therefore they are not used simultaneously WBBP The WCDMA Baseband Process Unit WBBP of the BBU3900 processes baseband signals Panels The WBBP has three typ...

Страница 110: ...en installed in slot 2 or slot 3 the WBBPd supports the IC function of uplink data Table 4 16 describes the specifications of the WBBP Table 4 16 Specifications of the WBBP Board Number of Cells UL CE Number DL CE Number WBBPa 3 128 256 WBBPb1 3 64 64 WBBPb2 3 128 128 WBBPb3 6 256 256 WBBPb4 6 384 384 WBBPd1 6 192 192 WBBPd2 6 384 384 WBBPd3 6 256 256 LEDs Table 4 17 describes the LEDs on the WBBP...

Страница 111: ...The LEDs are positioned below the SFP ports The WBBPd provides six LEDs indicating the status of the SFP links The LEDs are positioned above the SFP ports Table 4 18 describes the LEDs Table 4 18 LEDs indicating the status of the SFP links Label Color Status Description TX RX Red Green Steady green The CPRI link is available Steady red The optical module fails to receive signals Blinking red ON fo...

Страница 112: ...and output of optical and electrical signals NOTE The six CPRI ports are available on the WBBPd configured only in slot 2 or 3 and the CPRI ports are not available on the WBBPd configured in other port LBBP The LTE BaseBand Processing unit LBBP in the BBU3900 processes the baseband signals Panel The LBBP has two types of panels as shown in Figure 4 13 and Figure 4 14 Figure 4 13 Panel of the LBBPb...

Страница 113: ...Bandwidth of the Cell Antenna Configuration LBBPb 3 10M 2T2R 1 20M 2T2R 1 10M 4T4R LBBPc 3 20M 2T2R 3 10M 4T4R 1 20M 4T4R Table 4 22 describes the specifications of the LBBP working in LTE TDD mode Table 4 22 Specifications of the LBBP Board Number of Cells Bandwidth of the Cell Antenna Configuration LBBPc 3 20M 2T2R 3 10M 4T4R 1 20M 4T4R 1 8T8R LED There are three LEDs on the panel of the LBBP Ta...

Страница 114: ...ode The LBBP provides six LEDs indicating the status of the SFP links The LEDs are positioned above the SFP ports Table 4 24 describes the LEDs Table 4 24 LEDs indicating the status of the SFP links Label Color Status Description TX RX Red Green Steady green The CPRI link is available Steady red The optical module may fail to send or receive signals The failure may be caused by a faulty optical mo...

Страница 115: ...ports on the panel of the LBBP Table 4 25 Ports on the LBBP Label Connector Quantity Description CPRI0 to CPRI5 SFP female 6 The CPRI ports connect to the LRRUs or LRFUs for transmitting service data clock signals and synchronization information FAN The FAN unit for the BBU3900 controls the speed of fans and monitors the temperature of the fan unit It reports the status of the fans and fan unit an...

Страница 116: ... main control processing unit l Monitors the temperature at the air inlet l Dissipates heat l The FANc supports the function of reading and writing the information reported by the electronic label unit LED The FAN panel has only one LED which indicates the operating status of the fans Table 4 26 describes the LED 4 BTS3900 Components BTS3900 Hardware Description 4 24 Huawei Proprietary and Confide...

Страница 117: ...ls The UPEU is classified into three types Universal Power and Environment Interface Unit Type A UPEUa Universal Power and Environment Interface Unit Type B UPEUb and Universal Power and Environment Interface Unit Type C UPEUc The UPEUa and UPEUc convert 48 V DC power into 12 V DC and the UPEUb converts 24 V DC power into 12 V DC Figure 4 17 Figure 4 18 and Figure 4 19 show the panels of the UPEUa...

Страница 118: ...ng functions l Converts 48 V DC or 24 V DC power into 12 V DC which is the operating voltage of the boards l Provides two RS485 signal ports with each transmitting one RS485 signal and two Boolean signal ports with each transmitting four Boolean signals LED The UPEU has one LED which indicates the operating status of the UPEU Table 4 27 describes the LED 4 BTS3900 Components BTS3900 Hardware Descr...

Страница 119: ... 20 Slots in the BBU Table 4 28 describes the ports on the panel of the UPEU Table 4 28 Description on the ports Slot Label Connecto r Quantity Description Slot 19 24 V or 48 V 3V3 1 Introducing 24 V DC or 48 V DC power EXT ALM0 RJ 45 1 Port for Boolean inputs 0 to 3 EXT ALM1 RJ 45 1 Port for Boolean inputs 4 to 7 MON0 RJ 45 1 Port for RS485 input 0 MON1 RJ 45 1 Port for RS485 input 1 Slot 18 24 V...

Страница 120: ...e following functions l Provides two ports each transmitting one RS485 signal l Provides two ports each transmitting four Boolean signals l Transmits monitoring signals and alarm signals from external devices to the main control and transmission unit Ports The UEIU is configured in slot 18 It provides four ports with two ports transmitting two RS485 input signals and the other two ports transmitti...

Страница 121: ...This section describes the Universal Satellite card and Clock Unit USCU Panel There are two types of USCU USCUb1 and USCUb2 as shown in Figure 4 22 and Figure 4 23 Figure 4 22 Panel of the USCUb1 0 5 U Figure 4 23 Panel of the USCUb2 1 U 1 GPS port 2 RGPS port 3 TOD port 4 M 1PPS port 5 BITS port Functions The USCU has the following functions BTS3900 Hardware Description 4 BTS3900 Components Issue...

Страница 122: ...1s and off for 1s The board is running properly Blinking on for 0 125s and off for 0 125s Software is being loaded to the board or the board is not configured ALM Red Off The board is running properly and no alarm is generated On An alarm is generated and the board needs to be replaced Blinking on for 1s and off for 1s An alarm is generated The alarm may be caused due to faults in the related boar...

Страница 123: ...s or transmits 1PPS TOD signals TOD1 port RJ 45 connector Receives or transmits 1PPS TOD signals and receives TOD signals from the M1000 BITS port SMA coaxial connector Receives BITS clock signals and supports adaptive input of 2 048 MHz and 10 MHz clock reference source M 1PPS port SMA coaxial connector Receives 1PPS signals from the M1000 UTRP This describes the Universal Transmission Processing...

Страница 124: ... supporting two optical ports Figure 4 24 Panel of the UTRP2 supporting two optical ports Figure 4 25 shows the panel of the UTRP3 UTRP4 and UTRPb4 supporting eight E1s T1s Figure 4 25 Panel of the UTRP3 UTRP4 and UTRPb4 supporting eight E1s T1s RUN ALM ACT E1 T1 0 3 UTRP E1 T1 4 7 Figure 4 26 shows the panel of the UTRP6 supporting one STM 1 Figure 4 26 Panel of the UTRP6 supporting one STM 1 Fig...

Страница 125: ...r mode for co transmission in a dual mode base station l The UTRP6 supports one unchannelized STM 1 OC 3 port l The UTRP9 provides four 10M 100M 1000M Ethernet electrical ports and performs the functions of the MAC layer and physical layer l The cold backup is supported LEDs Table 4 34 describes the LEDs on the panel of the UTRP Table 4 34 LEDs on the panel of the UTRP Label Color Status Descripti...

Страница 126: ...s for indicating the status of the current link Table 4 35 describes the LEDs on the Ethernet ports of the UTRP2 and UTRP9 Table 4 35 LEDs on the Ethernet ports of the UTRP2 and UTRP9 Label Color Status Description LINK Green OFF The link is disconnected ON The link is properly connected ACT Orange Blinking The link is receiving or transmitting data OFF The link is not receiving or transmitting da...

Страница 127: ...ble 4 39 describes the ports of the UTRP9 supporting four electrical ports Table 4 39 Ports of the UTRP9 supporting four electrical ports Label Port Type Quantity Connector Type FE GE0 to FE GE3 FE GE electrical port 4 RJ 45 connector DIP Switches There is no DIP switch on the UTRP2 UTRP6 and UTRP9 The UTRP3 UTRP4 or UTRPb4 has three DIP switches numbered from SW1 to SW3 SW1 and SW2 are used to se...

Страница 128: ...FF OFF Balanced Mode ON ON ON ON Unbalanced Mode Other settings of the DIP bits Disabled Table 4 41 DIP switch SW2 on the UTRP DIP Switch DIP Status Description 1 2 3 4 SW2 OFF OFF OFF OFF Balanced Mode ON ON ON ON Unbalanced Mode Other settings of the DIP bits Disabled 4 BTS3900 Components BTS3900 Hardware Description 4 36 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd I...

Страница 129: ... ohms Other settings of the DIP bits Disabled UBRI The Universal Baseband Radio Interface Board UBRI provides extended CPRI optical or electrical ports to implement convergence distribution and multi mode transmission on the CPRI Panel Figure 4 30 shows the panel of the UBRI Figure 4 30 Panel of the UBRI Functions The UBRI performs the following functions l Provides extended CPRI optical or electr...

Страница 130: ...s generated ACT Green ON steady The board works properly OFF steady The board is not working The UBRI provides six LEDs indicating the status of the CRRI links which are above the SFP ports Table 4 44 describes the CPRI link status LED Table 4 44 CPRI link status LED Label Color State Description CPRIx Red Green ON green The CPRI link is available ON red The optical module fails to receive signals...

Страница 131: ...necting the BBU and the RF module 4 2 GRFU The GSM Radio Frequency Unit GRFU is designed on the basis of multi transceiver technology One GRFU supports 6 carriers Panel Figure 4 31 shows the GRFU panel Figure 4 31 GRFU panel BTS3900 Hardware Description 4 BTS3900 Components Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 4 39 ...

Страница 132: ... reverse power detection l Provides frequency synthesis and loopback test l Generates the CPRI clock recovers the CPRI clock of lost synchronization and detects alarms The GRFU consists of the high speed interface unit signal processing unit power amplifier and duplexer Figure 4 32 shows the logical structure of the GRFU Figure 4 32 Logical structure of the GRFU The High speed interface unit has t...

Страница 133: ...LEDs on the GRFU panel indicate the operating status of the GRFU Table 4 46 describes the LEDs on the GRFU panel Table 4 46 LEDs on the GRFU panel Label Color State Description RUN Green ON The power input is normal but the module is faulty OFF There is no power input or the module is faulty ON for 1s and OFF for 1s The module runs properly ON for 0 125s and OFF for 0 125s The module is loading so...

Страница 134: ...FF The SFP is out of position or the optical module is powered off CPRI1 Red Green On green The CPRI links are normal On red The reception of the optical module is abnormal and an alarm is generated ON for 1s and OFF for 1s red The CPRI link has a loss of lock error OFF The SFP is out of position or the optical module is powered off Ports Table 4 47 describes the ports on the GRFU panel Table 4 47...

Страница 135: ...el Power supply socket PWR 3V3 power Feeding power Monitoring port MON RJ 45 Monitoring port 4 3 DRFU The Double Radio Frequency Unit DRFU is a dual density RF unit A DRFU processes two carriers Panel There are two types of DRFU that is the DRFU of 900 MHz and DRFU of 1800 MHz The panels of the DRFUs are shown in Figure 4 33 and Figure 4 34 BTS3900 Hardware Description 4 BTS3900 Components Issue 0...

Страница 136: ...Figure 4 33 Panel of the DRFU of 900 MHz 4 BTS3900 Components BTS3900 Hardware Description 4 44 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 137: ...als to the GSM TX band After filtering and amplification the baseband signals are transmitted to the antenna system through the duplex filter l Receives uplink RF signals from the antenna system and then down converts the received signals to IF signals After amplification analog to digital conversion digital down conversion matched filtering automatic gain control AGC the IF signals are sent to th...

Страница 138: ... downlink TX channels l The uplink RX channels perform the following functions Down converts the received RF signals to Intermediate Frequency IF signals Amplifies the IF signals and performs IQ modulation Performs analog to digital A D conversion through the ADC Performs digital sampling Performs matched filtering Performs Digital Automatic Gain Control DAGC Encapsulates the data l The downlink T...

Страница 139: ...laced On for 1s and off for 1s Alarms are reported The alarms may be caused by the faults of the related boards or ports Therefore whether the module needs to be replaced cannot be decided Off No alarm is generated ACT Green On The board works properly with the TX channel enabled On for 1s and off for 1s The module works properly with the TX channel disabled VSWR Red On The VSWR alarm is generated...

Страница 140: ...Connecting to the antenna system ANT2 CPRI port SFP female CPRI0 Connecting to the lower level RFU during the cascading CPRI1 Connecting to the BBU or the upper level RFU in cascading mode Interconnecti on port for receiving RF signals QMA female RX1 IN Diversity RX port in antenna channel 1 RX1 OUT Diversity TX port in antenna channel 1 RX2 IN Diversity RX port in antenna channel 2 RX2 OUT Divers...

Страница 141: ... the direct frequency conversion technique in the transmit channel The baseband signals are modulated to WCDMA RF signals After being filtered and amplified or being combined the RF signals are transmitted through the duplex filter to the antenna for radio transmission BTS3900 Hardware Description 4 BTS3900 Components Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technol...

Страница 142: ...the WRFU Figure 4 37 Principle of the WRFU The high speed interface unit has the following functions l Transmits the signals received from the BBU to the signal processing unit l Transmits the signals received from the signal processing unit to the BBU The signal processing unit consists of two UL RX channels and one DL TX channel l The UL RX channel has the following functions Performs down conve...

Страница 143: ...125s The module is loading software or is not started ALM Red ON An alarm is generated and the module needs to be replaced Blinking ON for 1s and OFF for 1s An alarm is generated The alarm may be caused by the fault of the related module or port Therefore whether the module needs to be replaced cannot be determined OFF No alarm is generated ACT Green ON The module works properly the TX channel is ...

Страница 144: ...d off Ports Table 4 51 describes the ports on the WRFU panel Table 4 51 Ports on the WRFU panel Port Label Connector Description RF port ANT_RXB DIN RF RX port connected to the antenna system ANT_TX RXA DIN RF TX RX port connected to the antenna system CPRI CPRI0 SFP female Connected to the BBU or the upper level WRFU during the cascading CPRI1 SFP female Connected to the lower level WRFU during t...

Страница 145: ...uency Unit MRFU supports a maximum of six carriers Panel Figure 4 38 shows the panel of the MRFU Figure 4 38 Panel of the MRFU Functions The MRFU has the following functions BTS3900 Hardware Description 4 BTS3900 Components Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 4 53 ...

Страница 146: ...U consists of the high speed interface unit signal processing unit power amplifier and duplex unit Figure 4 39 shows the logical structure of the MRFU Figure 4 39 Logical structure of the MRFU The high speed interface unit has the following functions l Transmits the signals received from the BBU to the signal processing unit l Transmits the signals received from the signal processing unit to the B...

Страница 147: ...l of the MRFU Label Color Status Description RUN Green On The power input is normal and the module is faulty Off There is no power input or the module is faulty On for 1s and off for 1s The module runs properly On for 0 125s and off for 0 125s The module is loading software or is not started ALM Red On An alarm is generated and the module needs to be replaced Blinking on for 1s and off for 1s An a...

Страница 148: ... and an alarm is generated On for 1s and off for 1s red The CPRI link has a loss of lock error Off The SFP is out of position or the optical module is powered off Ports Table 4 53 describes the ports on the panel of the MRFU Table 4 53 Ports on the panel of the MRFU Port Label Connector Function RF Port ANT_RXB DIN connector RF RX port connected to the antenna system ANT_TX RXA DIN connector RF TX...

Страница 149: ...g ports MON RJ 45 connector Monitoring and maintaining port 4 6 LRFU LTE Radio Frequency Units LRFUs work in Frequency Division Duplex FDD mode Panel Figure 4 40 shows the panel of the LRFU Figure 4 40 Panel of the LRFU BTS3900 Hardware Description 4 BTS3900 Components Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 4 57 ...

Страница 150: ...ce l Reports the Received Signal Strength Indicator RSSI The downlink TX channels implement the following functions l Deframes the IQ signals of the BBU RFU interface l Shapes and filters downlink IQ signals performs digital up conversion digital to analog D A conversion and amplifies the power l Reports the transmit power l Provides overload protection of the power amplifier l Enables or disables...

Страница 151: ...y the fault of the related module or port Therefore the replacement of the module cannot be determined Off No alarm is generated ACT Green On The module works properly TX channel enabled On for 1s and Off for 1s The module is running TX channel disabled VSWR Red On red A VSWR related alarm is generated at the ANT_TX RXA port Blinking on for 1s and off for 1s A VSWR related alarm is generated at th...

Страница 152: ... Connector Description ANT_TX RXB DIN TX RX port for RF signals Used for the connection to the antenna system ANT_TX RXA DIN CPRI0 SFP female connector CPRI port Used for the connection to the BBU CPRI0 port and CPRI1 port work in mutual backup mode CPRI1 SFP female connector CPRI port Used for the connection to the BBU CPRI1 port and CPRI0 port work in mutual backup mode PWR 3V3 power connector P...

Страница 153: ... Table 4 56 Ports terminals and power switches on the panel of the DCDU 01 Port Label Connector Description Power input wiring terminals NEG OT terminal Negative input wiring terminal RTN Positive input wiring terminal Power output port SPARE2 SPARE1 BBU FAN and RFU5 to RFU0 Parallel terminal Providing 10 power outputs to the modules such as the BBU3900 RFUs and fan box Power switch SPARE2 SPARE1 ...

Страница 154: ... cabinet l Monitors the temperature l Supports fan speed adjustment based on temperature or controlled by the BBU l Stops the fans when the ambient temperature is low Figure 4 44 shows the ports on the FMU board Figure 4 44 Ports on the FMU board Table 4 57 describes the LEDs on the FMU board 4 BTS3900 Components BTS3900 Hardware Description 4 62 Huawei Proprietary and Confidential Copyright Huawe...

Страница 155: ...oard Table 4 58 Ports on the FMU board Port Type Label Connector Type Description Power port 48 V 3V3 power connector The port is used to introduce the 48 V DC power supply Sensor port SENSOR RJ 45 connector The port is connected to the ELU Communicatio n port COM OUT RJ 45 connector The port is connected to the lower level FMU COM IN RJ 45 connector The port is connected to the BBU or upper level...

Страница 156: ...onal and communicates with the BBU properly OFF There is no power supply or the module is faulty ACT Green ON The AISG link is available OFF The AISG link is unavailable Blinking irregularly The AISG link is in transmission state ALM Red ON An alarm is generated such as an overcurrent alarm OFF The module is functional Port ID There are eight ports on the GATM of which six are used to supply power...

Страница 157: ...power into 48 V DC power 4 11 1 Components of the Power Equipment DC DC The power equipment DC DC consists of the PSUs DC DC and power subrack DC DC 4 11 2 PSU DC DC The PSU is the power supply unit The PSU DC DC converts 24 V DC power into 48 V DC power 4 11 3 Power Subrack DC DC The power subrack DC DC provides the power input wiring terminals power output wiring terminals ALM port and PRESENT p...

Страница 158: ...ent DC DC Table 4 61 Components of the power equipment DC DC Component Description PSU DC DC For details see 4 11 2 PSU DC DC Power subrack DC DC For details see 4 11 3 Power Subrack DC DC 4 11 2 PSU DC DC The PSU is the power supply unit The PSU DC DC converts 24 V DC power into 48 V DC power Panel Figure 4 48 shows the panel of the PSU DC DC 4 BTS3900 Components BTS3900 Hardware Description 4 66...

Страница 159: ...ature protection and input overvoltage undervoltage protection and PSU out of position alarms if any LEDs Table 4 62 describes the LEDs on the panel of the PSU DC DC Table 4 62 LEDs on the panel of the PSU DC DC LED Color Status Description Power LED Green On The power supply is normal Off There is no power input or the fuse is damaged Protection LED Yellow Off The running status is normal BTS3900...

Страница 160: ...orts are used for the connections of the 24 V input power cables 48 V output power cables monitoring signal cable for the PSU and in position signal cable for the PSU respectively Exterior Figure 4 49 shows the power subrack DC DC Figure 4 49 Power Subrack DC DC 1 Power input wiring terminals 2 PRESENT port 3 ALM port 4 Power output wiring terminals Ports Table 4 63 describes the ports and termina...

Страница 161: ...er into 48 V DC power 4 12 1 Components of the Power Equipment AC DC The power equipment AC DC consists of the PMU PSUs AC DC and power subrack AC DC 4 12 2 PMU The Power and Environment Monitoring Unit PMU performs the power system management power distribution detection and alarm reporting functions 4 12 3 PSU AC DC The PSU is a power supply unit The PSU AC DC converts 220 V AC power into 48 V D...

Страница 162: ... DC For details see 4 12 3 PSU AC DC Power subrack AC DC For details see 4 12 4 Power Subrack AC DC 4 12 2 PMU The Power and Environment Monitoring Unit PMU performs the power system management power distribution detection and alarm reporting functions Exterior Figure 4 51 shows the PMU Figure 4 51 PMU 4 BTS3900 Components BTS3900 Hardware Description 4 70 Huawei Proprietary and Confidential Copyr...

Страница 163: ...nitors power distribution reports related alarms and reports dry contact alarms Ports and LEDs Figure 4 52 shows the front panel of the PMU Figure 4 52 Front panel of the PMU 1 RS232 RS422 ports 2 LEDs 3 Power supply test ports 4 TEST port 5 Battery control switch 6 COM port Table 4 65 describes the ports and switch on the PMU Table 4 65 Ports and switch on the PMU Port Switch Function RS232 RS422...

Страница 164: ... LEDs on the panel of the PMU Label Color Status Description RUN Green Blinking on for 1s and off for 1s The unit is functional and the communication with the BBU or upper level PMU is normal Blinking on for 0 125s and off for 0 125s The unit is functional but the communication with the BBU or upper level PMU fails If the unit does not communicate with the BBU or upper level PMU for one minute the...

Страница 165: ...witch has eight bits which are set before the PMU is delivered as shown in Figure 4 53 Figure 4 53 Right panel of the PMU 4 12 3 PSU AC DC The PSU is a power supply unit The PSU AC DC converts 220 V AC power into 48 V DC power Panel Figure 4 54 shows the panel of the PSU AC DC BTS3900 Hardware Description 4 BTS3900 Components Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei...

Страница 166: ...ion and input overvoltage undervoltage protection and PSU out of position alarm if any LEDs Table 4 67 describes the LEDs on the panel of the PSU AC DC Table 4 67 LEDs on the panel of the PSU AC DC LED Color Status Description Power LED Green On The power supply is normal Off There are faults such as no AC input or overvoltage and undervoltage of AC input on the mains or the PSU has no output Prot...

Страница 167: ...mote shutdown or an internal PSU fault 4 12 4 Power Subrack AC DC The power subrack AC DC provides the power input wiring terminals wiring terminals for batteries and battery power output wiring terminal The terminals are used for the connections of the input power cables output power cables and power cable for the batteries respectively Panel Figure 4 55 shows the panel of the power subrack AC DC...

Страница 168: ...Power output wiring terminals The LOAD1 and LOAD2 wiring terminals are used for the connections of the 48 V power cables and the RTN wiring terminals are used for the connections of the 48 V RTN cables Wiring terminals for batteries The BAT wiring terminal is used for the connection of negative pole for the batteries and the BAT wiring terminal is used for the connection of positive pole for the b...

Страница 169: ...tem CPRI port and RF 5 3 PGND Cables The PGND cables are used to ensure proper grounding of the cabinet and the modules in the cabinet 5 4 Equipotential Cable When the battery cabinet is working with the power cabinet one cabinet should be grounded through connecting the equipotential cable to the other cabinet 5 5 BTS3900 Power Cable The BTS3900 power cables consist of the cables leading power to...

Страница 170: ...sition signal cable for the PSU monitoring signal cable for the FAN unit BBU alarm cable and GPS clock signal cable 5 9 BTS3900 RF Cable The BTS3900 RF cables are the RF jumper and inter RFU RF signal cable 5 BTS3900 Cables BTS3900 Hardware Description 5 2 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 171: ...ar 5 4 Equipotenti al Cable OT terminal Wiring terminal for the equipotential cable OT terminal Wiring terminal for the equipotential cable 5 5 1 Input Power Cable for the Cabinet 48 V power cable OT terminal NEG and RTN on the DCDU 01 OT terminal External power supply device 5 5 1 Input Power Cable for the Cabinet 24 V power cable OT terminal Power input wiring terminals of the power subrack DC D...

Страница 172: ...5 3 Power Cable for the BBU 3V3 power connector PWR port on the UPEU Parallel terminal BBU port on the DCDU 01 5 5 2 Power Cable for the DCDU 01 Black OT terminal RTN port on the DCDU 01 OT terminal RTN wiring terminal for power output of the power subrack DC DC 5 5 2 Power Cable for the DCDU 01 Blue OT terminal NEG port on the DCDU 01 OT terminal LOAD wiring terminal for power output of the power...

Страница 173: ... Position Connector Installatio n Position Cables to be installed on site 5 6 1 E1 T1 Cable DB26 male connector E1 T1 port on the GTMU or WMPT or UTRP None External transmission equipment 5 6 2 FE GE Cable RJ 45 FE0 or FE1 port on the GTMU or WMPT or LMPT or UTRP RJ 45 External transmission equipment 5 6 3 FE GE Optical Cable LC connector SFP0 or SFP1 port on the GTMU or WMPT or UTRP l FC connecto...

Страница 174: ...latio n Position Connector Installatio n Position Cables installed before delivery 5 7 CPRI Electrical Cable SFP200 male connector CPRI ports on the GTMU or WBBP or LBBP SFP200 male connector CPRI ports on the RFU Cables to be installed on site The BTS3900 cabinet is delivered with boards installed and the CPRI cables in the cabinet are already installed The CPRI cables between multiple cabinets m...

Страница 175: ...alled before delivery 5 8 1 Monitoring Signal Cable for the PMU RJ 45 connector Left RS232 RS422 port on PMU RJ 45 connector MON1 port on the UPEU 5 8 2 Monitoring Signal Cable for the PSU DC DC RJ 45 connector ALM port on the power subrack DC DC Cord end terminal EXT ALM0 port on the UPEU 5 8 3 In Position Signal Cable for the PSU DC DC RJ 45 connector PRESENT port on the power subrack DC DC RJ 4...

Страница 176: ...nstallatio n Position Connector Installation Position Cables to be installed on site 5 9 1 RF Jumper DIN elbow male connector RF ports on the RFU DIN straight male connector Antenna system Cables installed before delivery 5 9 2 Inter RFU RF Signal Cable QMA elbow male connector RX OUT port on one RFU panel QMA elbow male connector RX IN port on another RFU panel 5 2 BTS3900 Cable Connections The c...

Страница 177: ... to the BTS3900 cabinet type The cable connections are also affected by the number of UPEUs and UEIUs configured in the BBU 5 2 5 RF Cable Connections The RFUs configured in a base station can be DRFUs GRFUs WRFUs and MRFUs The RF cable connections vary according to RFU types 5 2 1 Power Cable Connections This section describes the power cable connections of the BTS3900 cabinet Power Cable Connect...

Страница 178: ... of the BTS3900 24 V Figure 5 2 shows the power cable connections of the BTS3900 24 V Figure 5 2 Power cable connections of the BTS3900 24 V Table 5 7 lists the power cables of the BTS3900 24 V Table 5 7 Power cables of the BTS3900 24 V SN Description P1 to P6 For details see 5 5 5 Power Cable for the RFU P7 For details see 5 5 4 Power Cable for the Fan Box 5 BTS3900 Cables BTS3900 Hardware Descri...

Страница 179: ...wer supplies The following description takes the 220 V AC three phase power supply as an example Figure 5 3 shows the power cable connections of the BTS3900 220 V Figure 5 3 Power cable connections of the BTS3900 220 V Table 5 8 lists the power cables of the BTS3900 220 V Table 5 8 Power cables of the BTS3900 220 V SN Description P1 to P6 For details see 5 5 5 Power Cable for the RFU BTS3900 Hardw...

Страница 180: ...for data transmission Transmission over the E1 Cable Figure 5 4 shows the transmission cable connections when the E1 T1 cable is used for data transmission in a GSM only base station where only the GTMU is configured as the transmission board in the BBU3900 Figure 5 4 E1 T1 cable connections Table 5 9 describes the cable connections Table 5 9 E1 T1 cable connections Cable Number Cable Description ...

Страница 181: ... connections Table 5 11 FE GE Ethernet cable connections Cable Number Cable Description T1 See 5 6 2 FE GE Cable Figure 5 7 shows the transmission cable connections when the FE GE optical cable is used for data transmission Figure 5 7 FE GE optical cable connections Table 5 12 describes the cable connections Table 5 12 FE GE optical cable connections Cable Number Cable Description T1 See 5 6 3 FE ...

Страница 182: ...cribes the cable connections Table 5 13 E1 T1 cable connections 1 Cable Number Cable Description T1 See 5 6 1 E1 T1 Cable Figure 5 9 shows the transmission cable connections when only the E1 T1 cable is used for data transmission in a base station where only the WMPT and UTRP3 UTRP4 is configured in the BBU Figure 5 9 E1 T1 cable connections 2 Table 5 14 describes the cable connections Table 5 14 ...

Страница 183: ...rnet cable is used for data transmission in a base station where only the WMPT and UTRP9 is configured in the BBU Figure 5 11 FE GE Ethernet cable connections 2 Table 5 16 describes the cable connections Table 5 16 FE GE Ethernet cable connections 2 Cable Number Cable Description T1 and T2 See 5 6 2 FE GE Cable Figure 5 12 shows the transmission cable connections when only the FE GE optical cable ...

Страница 184: ... GE optical cable connections 2 Cable Number Cable Description T1 and T2 See 5 6 3 FE GE Optical Cable Transmission Cable Connections in the LTE Only Base Station In an LTE only base station the E1 T1 cable or FE GE optical cable can be used for data transmission Transmission over the E1 T1 Cable When the E1 T1 cable is used for data transmission the UTRP is required Figure 5 14 shows the transmis...

Страница 185: ...mission can be used Based on the IP co transmission the GSM UMTS base station can implement route backup That is four FE ports on the GTMU and LMPT panels are used Of the four FE ports two FE ports of one type are used for interconnection and the FE ports of the other type are connected to the transport network TDM Common Transmission Figure 5 16 shows the transmission cable connection for a GSM U...

Страница 186: ...s the cable Table 5 22 Transmission cable for a GSM UMTS base station in TDM common transmission mode 2 SN Description T1 For details see 5 6 1 E1 T1 Cable IP Over E1 Common Transmission Figure 5 18 shows the transmission cable connections for a GSM UMTS base station in IP common transmission mode when the E1 F1 port on the UMTS UTRP serves as the shared port to connect to the BSC and RNC and the ...

Страница 187: ...ansmission mode 2 Table 5 24 describes the cables Table 5 24 Transmission cables for a GSM UMTS base station in IP over E1 common transmission mode 2 SN Description T1 For details see 5 6 2 FE GE Cable T2 For details see 5 6 5 Cable Between Two FE Optical Ports IP Over FE Common Transmission Figure 5 20 shows the transmission cable connections for a GSM UMTS base station in IP co transmission mode...

Страница 188: ...cribes the cables Table 5 26 Transmission cable connections for a GSM UMTS base station in IP over FE common transmission mode 2 SN Description T1 For details see 5 6 4 Cable Between Two FE Electrical Ports T2 For details see 5 6 3 FE GE Optical Cable Route Backup Mode with IP Common Transmission In a GSM UMTS base station the route backup mode with IP common transmission has the following charact...

Страница 189: ...ission when the FE optical ports on the GTMU and WMPT are interconnected and the FE electrical ports on the two boards are connected to the BSC and RNC Figure 5 22 Transmission cable connections with FE optical ports for interconnection and FE electrical ports connected to the BSC and RNC Table 5 27 describes the cables Table 5 27 Transmission cables with FE optical ports for interconnection and F...

Страница 190: ...hows the transmission cable connections when the E1 T1 cables are used for data transmission on both the GSM and UMTS sides when a GSM UMTS base station works in separate transmission mode Figure 5 24 E1 T1 cable connections in separate transmission mode Table 5 29 describes the cable connections Table 5 29 E1 T1 cable connections in separate transmission mode Cable Number Cable Description T1 and...

Страница 191: ...ver E1 and IP over FE GE co transmission based on the interconnection between the FE ports optical or electrical type on the GTMU and LMPT panels Based on the co transmission route backup can be implemented That is four FE ports on the GTMU and LMPT panels are used Of the four FE ports two FE ports of one type are used for interconnection and the FE ports of the other type are connected to the tra...

Страница 192: ...mode 2 Table 5 33 describes the cables Table 5 33 Transmission cables for a GSM LTE base station in IP over E1 common transmission mode 2 SN Description T1 and T2 For details see 5 6 1 E1 T1 Cable T3 For details see 5 6 4 Cable Between Two FE Electrical Ports IP Over FE GE Common Transmission Figure 5 29 shows the transmission cable connections for a GSM LTE base station when the FE GE optical por...

Страница 193: ...s the cables Table 5 35 Transmission cables for a GSM LTE base station in IP over FE GE common transmission mode SN Description T1 For details see 5 6 2 FE GE Cable T2 For details see 5 6 5 Cable Between Two FE Optical Ports Route Backup Mode with IP Common Transmission In a GSM LTE base station the route backup transmission mode has the following characteristics l IP transmission is applied The G...

Страница 194: ... and the FE optical ports on the two boards are connected to the base station controller Figure 5 31 Transmission cable connections with FE electrical ports for interconnection and FE optical ports connected to the base station controller Table 5 36 describes the cables Table 5 36 Transmission cables with FE electrical ports for interconnection and FE optical ports connected to the base station co...

Страница 195: ...a GSM LTE base station when the E1 T1 port providing four E1s T1s on the GTMU is used for data transmission on the GSM side and the FE GE electrical port is used for data transmission on the LTE side Figure 5 33 Transmission cable connections in a base station in GSM 4E1 T1 LTE FE GE mode 1 Table 5 38 describes the cable connections Table 5 38 Transmission cable connections in a base station in GS...

Страница 196: ...a transmission on the LTE side Figure 5 35 Transmission cable connections in a base station in GSM 8E1 T1 LTE FE GE mode 1 Table 5 40 describes the cable connections Table 5 40 Transmission cable connections in a base station in GSM 8E1 T1 LTE FE GE mode 1 Cable Number Cable Description T1 and T2 See 5 6 1 E1 T1 Cable T3 See 5 6 2 FE GE Cable Figure 5 36 shows the transmission cable connections fo...

Страница 197: ...transmission on both the GSM and LTE sides Figure 5 37 Transmission cable connections in a base station in GSM FE GE LTE FE GE mode 1 Table 5 42 describes the cable connections Table 5 42 Transmission cable connections in a base station in GSM FE GE LTE FE GE mode 1 Cable Number Cable Description T1 and T2 See 5 6 2 FE GE Cable Figure 5 38 shows the transmission cable connections for a GSM LTE bas...

Страница 198: ...d hybrid transmission can be implemented IP Over E1 Common Transmission Figure 5 39 shows the transmission cable connections for a UMTS LTE base station when the E1 T1 port on the LTE UTRP is connected to the transmission equipment and the FE GE optical port on the LMPT is interconnected to the FE GE optical port on the WMPT Figure 5 39 Transmission cable connections for a UMTS LTE base station in...

Страница 199: ...over E1 common transmission mode 2 SN Description T1 and T2 For details see 5 6 1 E1 T1 Cable T3 For details see 5 6 4 Cable Between Two FE Electrical Ports IP Over FE GE Common Transmission Figure 5 41 shows the transmission cable connections for a UMTS LTE base station when the FE GE optical port on the LMPT is connected to the transmission equipment and the FE GE electrical port on the LMPT is ...

Страница 200: ...s see 5 6 2 FE GE Cable T2 For details see 5 6 5 Cable Between Two FE Optical Ports Route Backup Mode with IP Common Transmission In route backup mode the FE ports of one type either optical or electrical ports on the WMPT and LMPT are interconnected and the FE ports of the other type either optical or electrical ports on the two boards are connected to the transmission equipment In a UMTS LTE bas...

Страница 201: ... common transmission when the FE electrical ports on the WMPT and LMPT are interconnected and the FE optical ports on the two boards are connected to the transmission equipment Figure 5 43 Transmission cable connections for a UMTS LTE base station in route backup mode with IP common transmission 1 Table 5 48 describes the cables Table 5 48 Transmission cables for a UMTS LTE base station in route b...

Страница 202: ... a UMTS LTE base station in hybrid transmission mode When the UMTS FE GE port and the LTE FE GE port are used for data transmission hybrid transmission is not applicable Figure 5 45 shows the transmission cable connections in hybrid transmission mode UMTS E1 T1 port LTE FE GE optical port Figure 5 45 Transmission cable connections in hybrid transmission mode 1 Table 5 50 describes the cables Table...

Страница 203: ...manners of the transmission cable connections in separate transmission mode UMTS E1 T1 LTE FE GE Figure 5 47 shows the transmission cable connections for a UMTS LTE base station when the E1 T1 port providing four E1s T1s on the WMPT is used for data transmission on the UMTS side and the FE GE electrical port is used for data transmission on the LTE side Figure 5 47 Transmission cable connections i...

Страница 204: ...s in a base station in UMTS 4E1 T1 LTE FE GE mode 2 Cable Number Cable Description T1 See 5 6 3 FE GE Optical Cable T2 See 5 6 1 E1 T1 Cable Figure 5 49 shows the transmission cable connections for a UMTS LTE base station when the E1 T1 port providing eight E1s T1s on the UTRP3 or UTRP4 is used for data transmission on the UMTS side and the FE GE electrical port is used for data transmission on th...

Страница 205: ...E mode 2 Table 5 55 describes the cable connections Table 5 55 Transmission cable connections in a base station in UMTS 8E1 T1 LTE FE GE mode 2 Cable Number Cable Description T1 and T2 See 5 6 1 E1 T1 Cable T3 See 5 6 3 FE GE Optical Cable UMTS FE GE LTE FE GE Figure 5 51 shows the transmission cable connections for a UMTS LTE base station in separate transmission mode when the FE GE ports are use...

Страница 206: ...s the cable connections Table 5 57 Transmission cable connections in a base station in UMTS FE GE LTE FE GE mode 2 Cable Number Cable Description T1 See 5 6 3 FE GE Optical Cable T2 See 5 6 2 FE GE Cable 5 2 3 CPRI Cable Connections The CPRI cables are connected in star topology or chain topology In star topology each RFU is connected to the BBU separately In chain topology the RFUs are cascaded b...

Страница 207: ... shows the star topology of the WRFUs over CPRI ports when the WRFUs work in single band mode and support not more than three sectors in a base station with MIMO not supported BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 39 ...

Страница 208: ...base station with MIMO supported or when the bandwidth and carriers are expanded the CPRI ports are connected in chain topology as shown in Figure 5 56 and Figure 5 57 Figure 5 56 Chain topology over CPRI ports 5 BTS3900 Cables BTS3900 Hardware Description 5 40 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 209: ...nnections in the 3 x 10 MHz 2T2R configuration Figure 5 58 CPRI cable connections in the 3 x 10 MHz 2T2R configuration Figure 5 59 shows the CPRI cable connections in the 3 x 20 MHz 2T2R configuration BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 41 ...

Страница 210: ... x 10 MHz 4T4R configuration Figure 5 60 CPRI cable connections in the 3 x 10 MHz 4T4R configuration Figure 5 61 shows the CPRI cable connections in the 3 x 20 MHz 4T4R configuration 5 BTS3900 Cables BTS3900 Hardware Description 5 42 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 211: ...is configured When the MRFUs support more than three sectors two WBBPbs or one WBBPd are configured When the MRFUs work in single band mode and support three sectors the CPRI ports are connected in dual star topology as shown in Figure 5 62 and Figure 5 63 Figure 5 62 Dual star topology over CPRI ports 1 BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confi...

Страница 212: ... CPRI ports are connected in dual star topology as shown in Figure 5 64 and Figure 5 65 Figure 5 64 Dual star topology over CPRI ports 3 Figure 5 65 Dual star topology over CPRI ports 4 5 BTS3900 Cables BTS3900 Hardware Description 5 44 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 213: ...imum of 12 RFUs Figure 5 66 and Figure 5 67 show the CPRI cable connections in a base station in co cabinet mode Figure 5 66 CPRI cable connections in a co cabinet base station with WRFUs and DRFUs GRFUs 1 BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 45 ...

Страница 214: ... mode and support three sectors and when the WRFU support three sectors in a base station with MIMO not supported the CPRI cables are connected in the manner shown in Figure 5 68 5 BTS3900 Cables BTS3900 Hardware Description 5 46 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 215: ...WRFU support three sectors in a base station with MIMO supported the CPRI cables are connected in the manner shown in Figure 5 69 Figure 5 69 CPRI cable connections in a co cabinet base station with MRFUs and WRFUs 2 BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 47 ...

Страница 216: ...able connections in a co cabinet base station with MRFUs and DRFUs GRFUs CPRI Cable Connections in the GSM LTE Base Station CPRI Cable Connections in the Co Module GSM LTE Base Station The MRFUs working in GSM LTE mode are connected in the dual star topology as shown in Figure 5 71 5 BTS3900 Cables BTS3900 Hardware Description 5 48 Huawei Proprietary and Confidential Copyright Huawei Technologies ...

Страница 217: ...2 shows the CPRI cable connections in a base station in co cabinet mode Figure 5 72 CPRI cable connections in co cabinet mode CPRI Cable Connections in the UMTS LTE Base Station BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 49 ...

Страница 218: ... the BTS3900 cabinet type The cable connections are also affected by the number of UPEUs and UEIUs configured in the BBU NOTE If any device is not configured at the site neglect the device and its cable connection Monitoring signal cable connections of the BTS3900 48 V DC The monitoring signal cable connections of the BTS3900 48 V DC are shown in Figure 5 74 and listed in Table 5 58 5 BTS3900 Cabl...

Страница 219: ... Box S4 See 5 8 5 Fan Box Cascade Signal Cable S5 See 5 8 6 Monitoring Signal Cable for the EMU S6 and S7 See 5 8 7 Monitoring Signal Cable for the GATM Monitoring signal cable connections of the BTS3900 24 V DC The monitoring signal cable connections of the BTS3900 24 V DC are shown in Figure 5 75 and listed in Table 5 59 BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Pr...

Страница 220: ...g Signal Cable for the Fan Box S4 See 5 8 5 Fan Box Cascade Signal Cable S5 See 5 8 6 Monitoring Signal Cable for the EMU S6 and S7 See 5 8 7 Monitoring Signal Cable for the GATM S8 See 5 8 2 Monitoring Signal Cable for the PSU DC DC S9 and S10 See 5 8 3 In Position Signal Cable for the PSU DC DC 5 BTS3900 Cables BTS3900 Hardware Description 5 52 Huawei Proprietary and Confidential Copyright Huawe...

Страница 221: ...or the Fan Box S4 See 5 8 5 Fan Box Cascade Signal Cable S5 and S6 See 5 8 1 Monitoring Signal Cable for the PMU S7 See 5 8 6 Monitoring Signal Cable for the EMU S8 and S9 See 5 8 7 Monitoring Signal Cable for the GATM 5 2 5 RF Cable Connections The RFUs configured in a base station can be DRFUs GRFUs WRFUs and MRFUs The RF cable connections vary according to RFU types RF Cable Connections for DRF...

Страница 222: ...ctions in 1T2R mode 1 With one RX channel and two TX channels the following items are configured for two carriers l A pair of dual polarized antennas l One DRFU Figure 5 77 shows the RF cable connections With one RX channel and two TX channels the following items are configured for four carriers l A pair of dual polarized antennas l Two DRFUs Figure 5 78 describes the RF cable connections 5 BTS390...

Страница 223: ...ir of dual polarized antennas l Two DRFUs Figure 5 78 shows the RF cable connections RF Cable Connections for GRFUs The GRFU supports six carriers The following description is based on the RF cable connections for GRFUs with a single sector The GRFU supports only the 1T2R configuration Cable Connections with Three Carriers The following items are configured for three carriers l A pair of dual pola...

Страница 224: ...nections with Nine Carriers The following items are configured for nine carriers l A pair of dual polarized antennas l Two GRFUs Figure 5 80 describes the RF cable connections 5 BTS3900 Cables BTS3900 Hardware Description 5 56 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 225: ...following items are configured for 14 carriers l Two pairs of dual polarized antennas l Three GRFUs Figure 5 81 describes the RF cable connections BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 57 ...

Страница 226: ...ollowing items are configured for 24 carriers l Two pairs of dual polarized antennas l Four GRFUs Figure 5 82 describes the RF cable connections 5 BTS3900 Cables BTS3900 Hardware Description 5 58 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 227: ...th a single sector Cable Connections in 1T2R Mode With one RX channel and two TX channels the following items are configured for one to four carriers l A pair of dual polarized antennas l One WRFU Figure 5 83 describes the RF cable connections BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 59 ...

Страница 228: ...lowing items are configured for five to eight carriers l A pair of dual polarized antennas l Two WRFUs Figure 5 84 describes the RF cable connections 5 BTS3900 Cables BTS3900 Hardware Description 5 60 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 15 ...

Страница 229: ...RFUs Figure 5 84 shows the RF cable connections Cable Connections in 2T4R Mode With two RX channels and four TX channels the following items are configured for one to four carriers l Two pairs of dual polarized antennas l Two WRFUs Figure 5 85 describes the RF cable connections BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Te...

Страница 230: ...following description is based on the RF cable connections for LRFUs supporting a single sector The LRFU supports only the 2T2R configuration RF Cable Connections in 2T2R Mode In 2T2R mode the following items are configured l A dual polarized antenna l An LRFU Figure 5 86 shows RF cable connections 5 BTS3900 Cables BTS3900 Hardware Description 5 62 Huawei Proprietary and Confidential Copyright Hua...

Страница 231: ...mode In 4T4R mode the following items are configured l Two dual polarized antennas l Two LRFUs Figure 5 87 shows RF cable connections BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 63 ...

Страница 232: ...r The MRFU supports only the 1T2R configuration Cable Connections in G3U1 Mode The following items are configured for three carriers in GSM and one carrier in UMTS l A pair of dual polarized antennas l One MRFU Figure 5 88 describes the RF cable connections 5 BTS3900 Cables BTS3900 Hardware Description 5 64 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 04 2011 02 1...

Страница 233: ... configured for nine carriers in GSM and one carrier in UMTS l A pair of dual polarized antennas l Two MRFUs Figure 5 89 describes the RF cable connections BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 5 65 ...

Страница 234: ... and two carriers in UMTS l A pair of dual polarized antennas l Two MRFUs Figure 5 89 shows the RF cable connections 5 3 PGND Cables The PGND cables are used to ensure proper grounding of the cabinet and the modules in the cabinet PGND Cable for the Cabinet The PGND cable for the cabinet is green and yellow with a cross sectional area of 25 mm2 Figure 5 90 shows the PGND cable for the cabinet 5 BT...

Страница 235: ... the power cabinet one cabinet should be grounded through connecting the equipotential cable to the other cabinet Structure The equipotential cable is a single cable with OT terminals at both ends It is a yellow and green cable with cross sectional area of 16 mm2 The OT terminals should be made on site Figure 5 92 show the equipotential cable Figure 5 92 Equipotential cable 1 OT terminals BTS3900 ...

Страница 236: ...the fan box through the power cable for the fan box 5 5 5 Power Cable for the RFU The DCDU 01 feeds 48 V DC power into the RFU through the power cable for the RFU 5 5 6 Power Cable for the GATM The power cable for the GATM feeds 48 V DC power into the GATM 5 5 1 Input Power Cable for the Cabinet The input power cable for the cabinet feeds DC or AC power into the cabinet 48 V Power Cable The 48 V p...

Страница 237: ... M6 Black NOTE The 24 V power cable consists of two pairs of wires with each pair containing a red wire and a black wire AC Power Cable The BTS3900 cabinet supports three types of AC power supply That is the 220 V AC single phase 220 V AC three phase and 110 V AC dual live wire The AC power cable feeds AC power into a cabinet Figure 5 95 shows the AC power cable Table 5 63 describes the AC power c...

Страница 238: ...m2 N wire 110 V dual live wire power cable L1 wire 6 mm2 L2 wire NOTE The colors and exteriors of cables delivered by Huawei vary according to countries and areas If cables are purchased at local markets the cables must comply with the local rules and regulations 5 5 2 Power Cable for the DCDU 01 The power equipment DC DC and power equipment AC DC provide 48 V DC power to the DCDU 01 through the D...

Страница 239: ...lue 16 mm2 M6 Black Power equipment AC DC Blue 16 mm2 M6 Black 5 5 3 Power Cable for the BBU The DCDU 01 feeds 48 V DC power into the BBU through the power cable for the BBU Exterior Figure 5 97 shows the power cable for the BBU Figure 5 97 Power cable for the BBU 1 3V3 power connector 2 Parallel terminal BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011 02 15 Huawei Proprietary and Conf...

Страница 240: ...n box Figure 5 98 Power cable for the fan box 1 3V3 power connector 2 Parallel terminal Pin Assignment Table 5 66 describes the pin assignment for the wires of the power cable for the fan box Table 5 66 Pin assignment for the wires of the power cable for the fan box Cable X1 End X2 End Cable Color W1 A3 B1 Black W2 A1 B2 Blue 5 5 5 Power Cable for the RFU The DCDU 01 feeds 48 V DC power into the R...

Страница 241: ...wer cable for the RFU Cable X1 End X2 End Cable Color W1 A3 B1 Black W2 A1 B2 Blue 5 5 6 Power Cable for the GATM The power cable for the GATM feeds 48 V DC power into the GATM Structure One end of the power cable for the GATM is a parallel terminal and the other end is a 3V3 power connector Figure 5 100 shows the power cable for the GATM BTS3900 Hardware Description 5 BTS3900 Cables Issue 04 2011...

Страница 242: ... cable 5 6 1 E1 T1 Cable The E1 T1 cable connects the BBU to the external transmission device and transmits baseband signals 5 6 2 FE GE Cable The FE GE cable connects the BBU to the transmission device through routing devices and transmits baseband signals 5 6 3 FE GE Optical Cable The FE GE optical cable is used to transmit optical signals between the BBU3900 and the transmission device This cab...

Страница 243: ...made on site according to site requirements Figure 5 101 shows an E1 T1 cable Figure 5 101 E1 T1 cable 1 DB26 male connector Table 5 69 describes the connectors of the 75 ohm E1 coaxial cable Table 5 69 Connectors of the 75 ohm E1 coaxial cable Cable One End The other End 75 ohm E1 coaxial cable DB26 male connector L9 male connector L9 female connector SMB female connector BNC male connector SMZ m...

Страница 244: ...ip 7 RX4 X1 8 Ring RX4 X1 19 Tip 2 TX1 X1 20 Ring TX1 X1 21 Tip 4 TX2 X1 22 Ring TX2 X1 23 Tip 6 TX3 X1 24 Ring TX3 X1 25 Tip 8 TX4 X1 26 Ring TX4 Table 5 71 Pin assignment for the wires of the 120 ohm E1 twisted pair cable Pins of the DB26 Male Connector Wire Color Wire Type Cable Labels X 1 Blue Twisted pair RX1 X 2 White RX1 X 3 Orange Twisted pair RX2 X 4 White RX2 X 5 Green Twisted pair RX3 X...

Страница 245: ...sion device through routing devices and transmits baseband signals NOTE The maximum length of the FE GE cable for remote connection is 100 m Exterior The FE GE cable is a shielded straight through cable It has an RJ 45 connector at each end as shown in Figure 5 102 Figure 5 102 FE GE cable 1 RJ 45 connector Pin Assignment Table 5 72 describes the pin assignment for the wires of the FE GE cable BTS...

Страница 246: ... The FE GE optical cable is used to transmit optical signals between the BBU3900 and the transmission device This cable is optional Exterior The FE GE optical cable has an LC connector at one end and an FC connector SC connector or LC connector at the other end as shown in Figure 5 103 Figure 5 104 and Figure 5 105 respectively Figure 5 103 FE GE optical cable FC and LC connectors Figure 5 104 FE ...

Страница 247: ...s connects the GTMU and the WMPT to implement IP transmission Structure The cable between two FE electrical ports has an RJ 45 connector at each end as shown in Figure 5 106 Figure 5 106 Cable between two FE electrical ports 1 RJ 45 connector 5 6 5 Cable Between Two FE Optical Ports The cable between two FE optical ports connects the GTMU and the WMPT to implement IP transmission Structure The cab...

Страница 248: ...he monitoring signal cable for the PMU transmits the environment alarm information collected by the PMU to the BBU 5 8 2 Monitoring Signal Cable for the PSU DC DC The monitoring signal cable for the PSU DC DC is used for the BBU to monitor the power status of the PSUs and receive related alarms 5 8 3 In Position Signal Cable for the PSU DC DC The in position signal cable for the PSU DC DC is used ...

Страница 249: ...or the ELU is used to report the cabinet type information detected by the ELU to the fan box 5 8 1 Monitoring Signal Cable for the PMU The monitoring signal cable for the PMU transmits the environment alarm information collected by the PMU to the BBU Exterior Figure 5 109 shows the monitoring signal cable for the PMU Figure 5 109 Monitoring signal cable for the PMU 1 RJ 45 connector Pin Assignment...

Страница 250: ... the PSUs The other wires are tied to the column of the cabinet Figure 5 110 shows the monitoring signal cable for the PSU DC DC Figure 5 110 Monitoring signal cable for the PSU DC DC 1 Monitoring signal cable for the PSU DC DC 5 8 3 In Position Signal Cable for the PSU DC DC The in position signal cable for the PSU DC DC is used for the BBU to monitor the in position status of the PSU Exterior Fi...

Страница 251: ... Twisted pair X1 2 X2 2 Orange X1 3 X2 3 White Twisted pair X1 6 X2 6 Green X1 5 X2 5 White Twisted pair X1 4 X2 4 Blue X1 7 X2 7 White Twisted pair X1 8 X2 8 Brown 5 8 4 Monitoring Signal Cable for the Fan Box The monitoring signal cable for the fan box is used for the BBU to monitor the running status of the fan box Exterior Figure 5 112 shows the monitoring signal cable for the fan box BTS3900 ...

Страница 252: ...1 X2 1 White Twisted pair cable X1 2 X2 2 Orange X1 3 X2 3 White Twisted pair cable X1 6 X2 6 Green X1 5 X2 5 White Twisted pair cable X1 4 X2 4 Blue X1 7 X2 7 White Twisted pair cable X1 8 X2 8 Brown 5 8 5 Fan Box Cascade Signal Cable Fan box cascade signal cable is used to connect two fan boxes Structure Figure 5 113 shows the fan box cascade signal cable 5 BTS3900 Cables BTS3900 Hardware Descri...

Страница 253: ...3 X2 3 White Twisted pair cable X1 6 X2 6 Green X1 5 X2 5 White Twisted pair cable X1 4 X2 4 Blue X1 7 X2 7 White Twisted pair cable X1 8 X2 8 Brown 5 8 6 Monitoring Signal Cable for the EMU The monitoring signal cable for the EMU transmits monitoring signals from the EMU to the BBU Exterior Figure 5 114 shows the monitoring signal cable for the EMU BTS3900 Hardware Description 5 BTS3900 Cables Is...

Страница 254: ...ector Wire Color Wire Type Label X1 1 X2 3 White Twisted pair TX X1 2 X2 7 Orange TX X1 5 X2 6 White Twisted pair RX X1 4 X2 2 Blue RX 5 8 7 Monitoring Signal Cable for the GATM This cable connects the BBU and GATM enabling the BBU to transmit control signals to the GATM and enabling the GATM to report alarms to the BBU Structure Figure 5 115 shows the monitoring signal cable for the GATM 5 BTS390...

Страница 255: ... X1 6 X2 6 Green X1 5 X2 5 White Twisted pair X1 4 X2 4 Blue X1 7 X2 7 White Twisted pair X1 8 X2 8 Brown 5 8 8 BBU Alarm Cable The BBU alarm cable transmits alarm signals from an external alarm device to the BBU Exterior The BBU alarm cable has an RJ 45 connector at each end as shown in Figure 5 116 However an RJ 45 connector at one end may be removed and an appropriate terminal may be added acco...

Страница 256: ...1 2 Orange X2 2 Boolean value input 4 GND X1 3 White and green Twisted pair X2 3 Boolean value input 5 X1 6 Green X2 6 Boolean value input 5 GND X1 5 White and blue Twisted pair X2 5 Boolean value input 6 X1 4 Blue X2 4 Boolean value input 6 GND X1 7 White and brown Twisted pair X2 7 Boolean value input 7 X1 8 Brown X2 8 Boolean value input 7 GND EXT ALM0 X1 1 White and orange Twisted pair X2 1 Bo...

Страница 257: ...8 Boolean value input 3 GND 5 8 9 GPS Clock Signal Cable The GPS clock signal cable is an optional cable that transmits GPS clock signals from the GPS antenna system to the BBU The GPS clock signals serve as the clock reference of the BBU Exterior The GPS clock signal cable has an SMA male connector at one end and an N type female connector at the other end as shown in Figure 5 117 Figure 5 117 GP...

Страница 258: ...le for the ELU X1 End X2 End Wire Color Wire Type X1 1 X2 1 White Twisted pair X1 2 X2 2 Orange X1 3 X2 3 White Twisted pair X1 6 X2 6 Green X1 5 X2 5 White Twisted pair X1 4 X2 4 Blue X1 7 X2 7 White Twisted pair X1 8 X2 8 Brown 5 9 BTS3900 RF Cable The BTS3900 RF cables are the RF jumper and inter RFU RF signal cable 5 9 1 RF Jumper The RF jumper connects the RFU and the feeder of the antenna sy...

Страница 259: ...5 119 RF jumper 1 DIN straight male connector 2 DIN elbow male connector NOTE Macro base stations use super flexible 1 2 inch jumpers 5 9 2 Inter RFU RF Signal Cable The inter RFU RF signal cable is used for transmitting the received diversity signals between two RFUs The cable connects the RX IN port on one RFU and the RX OUT port on another RFU Structure Figure 5 120 shows the inter RFU RF signa...

Страница 260: ......

Страница 261: ...DCDU 04 and DCDU 03 For details see the PS4890 User Guide 6 2 EMU The Environment Monitoring Unit EMU is an environmental monitoring device that monitors environmental conditions of the equipment room 6 3 DDF This section describes the structure functions features and technical specifications of the DDF BTS3900 Hardware Description 6 BTS3900 Auxiliary Equipment Issue 04 2011 02 15 Huawei Proprieta...

Страница 262: ...ctions between the BTS3900 and the PS4890 Figure 6 1 Cable connections between the BTS3900 and the PS4890 Table 6 1 lists the cables between the BTS3900 and the PS4890 Table 6 1 Cables between the BTS3900 and the PS4890 SN Cable P1 P2 For details see Output Power Cable for the DCDU 04 6 BTS3900 Auxiliary Equipment BTS3900 Hardware Description 6 2 Huawei Proprietary and Confidential Copyright Huawe...

Страница 263: ...og signals and output control signals l Provides the RS485 and RS232 ports for the communication with the base station For details about the structure and functions of the EMU see HUAWEI QCKG1EMU User Guide 6 3 DDF This section describes the structure functions features and technical specifications of the DDF Structure Figure 6 2 shows the structure of the DDF Figure 6 2 Structure of the DDF 1 Ala...

Страница 264: ...fers 16 alarm signals and eight E1s with each E1 grounded l Supports wire punching from the front Technical Specification Table 6 2 describes the technical specifications of the DDF Table 6 2 Technical specifications of the DDF Item Specification Dimensions height x width x depth 44 mm x 483 mm x 59 mm Weight 1 kg Working rate 2 Mbit s Characteristic impedance 120 ohms Inter wire bundle cross nois...

Отзывы: