Figure 5-90
PGND cable for the cabinet
(1) OT terminal
PGND Cable for the Modules
The PGND cable for the modules is green and yellow with a cross-sectional area of 6 mm
2
.
shows the PGND cable for the modules.
Figure 5-91
PGND cable for the modules
(1) OT terminal
5.4 Equipotential Cable
When the battery cabinet is working with the power cabinet, one cabinet should be grounded
through connecting the equipotential cable to the other cabinet.
Structure
The equipotential cable is a single cable with OT terminals at both ends. It is a yellow and green
cable with cross-sectional area of 16 mm
2
. The OT terminals should be made on site.
show the equipotential cable.
Figure 5-92
Equipotential cable
(1) OT terminals
BTS3900
Hardware Description
5 BTS3900 Cables