Installing Cables
Ground cable
Optical fiber
AC power cable
● AP6610DN external cable arrangement drawing
3. Put the network cable through the hole on the waterproof PG connector.
a
b
c
d
4. Connect the RJ45 connector to the AP and secure the waterproof PG connector, as shown in figures b, c, and d.
a
b
c
d
Ensure that the RJ45 connector is correctly connected to the AP. Otherwise, the network cable may be damaged.
Before removing the network cable, remove the waterproof PG connector, and then remove the RJ45 connector from
the AP.
Waterproof PG connector
CAUTION
Feed line
Feed line
Feed line
Feed line
Network
cable
●
Connecting network cables
1. Use a shield straight-through cable. Cut the cable of proper length based on the distance between the AP and the PoE
device, peel the insulation on both ends of the network cable, and crimp the wires to RJ45 connectors.
2. Make a network cable onsite according to the following pin assignment. Otherwise, the communication quality is
affected even if devices can be connected.
X1 Pin
1
2
3
4
5
6
7
8
X2 Pin
1
2
3
4
5
6
7
8
Wire Color
White and orange
Orange
White and green
Blue
White and blue
Green
White and brown
Brown
6