Installing an AP

● Select an appropriate installation position and leave space above and around the device for cooling air circulation.
● Outdoors Aps are used for hotspot coverage and often installed against walls or poles. The pole diameter is 48 mm to 114 mm.

AP6610DN-AGN-US dimensions (unit: mm) without a backplane 
support.

Recommended AP6610DN-AGN-US installation space 
(unit: mm).

● Installing the AP6610DN-AGN-US against a Wall:

 

330

83

3

0

6

Hexagon 

socket head 

cap screw

Field strength

场强示意

1.   Fix the wall-mounting bracket to the wall, adjust the
      installation position, and use the marker, level, and 
      measuring tape to mark the drilling positions where
      expansion bolts are installed.

2.   Use #8 drill bit to drill 35 mm to 40 mm deep holes in the 
      drilling positions and install expansion bolts. Screw the nut 
      into the expansion tube, hammer the expansion bolt into a 
      hole until the flat washer is flattened against the wall, and 
      remove the nuts, spring washer, and flat washer in order.

Flat washer

Spring washer

Nuts

3.  Use four M4*12 hexagon socket head cap screws to fasten the wall-mounting bracket to the AP.

4.  Pinch the

 

wall-mounting bracket  on the expansion 

     bolts, and  fasten the flat washer, spring washer, and
     nuts in order.

5.  Slide the AP into the wall-mounting bracket to complete
      installation.

4

64mm

3

7

m

m

Содержание AP6610DN-AGN-US

Страница 1: ...AP6610DN AGN US Outdoor Wireless LAN Access Point Quick Start Guide HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...vices and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has...

Страница 3: ...ed could result in equipment damage data loss performance degradation or unexpected results Provides additional information to emphasize or supplement important points of the main text 2 Change History Changes between document issues are cumulative Therefore the latest document issue contains all the changes in previous issues Change in Issue 01 2012 09 30 Initial commercial release ...

Страница 4: ...o fiber An optical module is required Used for Ethernet connections Connected to an AC power module Connected to the feeder Connected to the feeder 5 2 Expansion bolt PCS 6 2 M4X12 hexagon socket head cap screw PCS Press and hold down the Reset button for 3 seconds to restore the factory settings and restart the AP 7 Item Description No Product functions 10 11 1 1 Item Quantity Unit PCS PCS Warran...

Страница 5: ...lation position and use the marker level and measuring tape to mark the drilling positions where expansion bolts are installed 2 Use 8 drill bit to drill 35 mm to 40 mm deep holes in the drilling positions and install expansion bolts Screw the nut into the expansion tube hammer the expansion bolt into a hole until the flat washer is flattened against the wall and remove the nuts spring washer and ...

Страница 6: ...on the hoop 2 Slide the AP that has the connector fastened into the wall mounting bracket The procedure for installing the AP6610DN AGN US against a horizontal pole is similar to the procedure for installing the AP6610DN AGN US against a vertical pole Installing the Security Lock To prevent unauthorized personnel from moving the AP lock the AP The preceding figure shows the security lock The carri...

Страница 7: ...ensure that it is connected to a ground cable a Waterproof adhesive tape Ground cable NOTE Surge protection device c b Waterproof adhesive tape Feed line Feed line When no antenna is installed on the 5G antenna interface cover the interface with a dustproof cap and wrap the dustproof cap with insulating tape and waterproof tape Wrap the feed line using one layer PVC black insulation tape three lay...

Страница 8: ...onnecting AC power cables 1 Make an AC power cable onsite cut the cable of proper length Make a cable according to figure 1 L N PE pin arrangement must be correct 2 When connecting the AC power cable to the AP align the socket to the red point of the connector and insert the waterproof connector When a crack sound is heard the AC power cable is installed properly When removing the AC power cable p...

Страница 9: ...components Connector jacks can t be short circuited Connections between the metal shell and the connector jacks can t be short circuited Cable core wires are connected properly to the corresponding connector jacks d Protection The device is placed outdoors warp up the connector using three layers of PVC insulation tapes to prevent it from being damaged as shown in the following figure CAUTION Each...

Страница 10: ... the shielded cable should have good electric contact with the metal shell of the equipment they connect to 4 Ground cables must be separated from signal cables to reduce interference between them 5 Do not add any switch or fuse on the ground cable 6 Do not use another device for an electrical connection with the ground cable 7 All metal components in the shell must be securely connected to the gr...

Страница 11: ...e packets are being transmitted Off The system is working properly the Ethernet is connected and radios are disabled The indicator blinks more quickly when more data is being transmitted Blinking yellow The system is working properly but the Ethernet is not connected The AP has wireless users connected to the 5 GHz band and is transmiting data The indicator blinks more quickly when more packets ar...

Страница 12: ...the ping 192 168 0 1 command on the PC to check whether the PC can be pinged If the ping operation succeeds the connection is set up successfully If the ping operation fails The connection fails to be set up Check whether the network cable works properly Step 3 Access the command line window on the PC For example if the PC runs Windows XP choose Start Run and enter cmd in the displayed dialog box ...

Страница 13: ...he hazardous substance contained in all the homogeneous materials of this part is above the limit requirement Hazardous Substances Pb Hg Cd Cr6 PBB PBDE Part Mechanical part Board circuit module Signal cable Cable connector Power adapter Auxiliary equipment O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O Declaration on Hazardous Substances in Electronic Information Products QUALIFICATI...

Страница 14: ...sed by improper handling in transportation and assembly 2 The defects are caused by the fact that the product is dismantled or altered by anyone that is not from a Huawei authorized service partner 3 The defects are caused by the fact that the product is used in a harsh environment that is not suitable for the operation of the product 4 The defects are caused by any force majeure including but not...

Страница 15: ...HUAWEI TECHNOLOGIES CO LTD Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China Http enterprise huawei com ...

Отзывы: