Procedure
1. Remove a power cable from a PSU to
simulate a PSU hardware error.
2. Log in to the iBMC WebUI, choose
Alarm and SEL
>
Current Alarms
,
and check for PSU alarms.
3. Check whether the error code displayed
on the fault diagnosis LED of the front
panel correctly indicates the same error
as the alarm.
Expected Results
The fault diagnosis LED correctly indicates
the PSU hardware error.
l
If the power cable of the left PSU is
removed, the fault diagnosis LED
displays "P01".
l
If the power cable of the right PSU is
removed, the fault diagnosis LED
displays "P02".
Test Result
Remarks
4.2.3 Querying and Changing the iBMC IP Address
Case No.
4.2.3
Test Objective
To verify that the iBMC IP address can be successfully queried
and changed.
Test Networking
Diagram
See section
.
Prerequisites
The server is powered on.
5288 V5 Server
Acceptance Guide
4 Test Cases and Records