Procedure
Step 1
On the
M2000 client
, choose
Configuration
>
Auto Deployment
>
eNodeB Auto
Deployment
. The
eNodeB Auto Deployment
tab page is displayed.
Step 2
Select one or more commissioning tasks.
Step 3
Click
to view the automatic deployment report, which includes the health check report.
----End
5.9 Checking the Operating Status of the Base Station
The operating status of a base station can be viewed in the commissioning report.
5.9.1 Checking the Running Status of the GBTS
You can analysis the GBTS commissioning report to infer the running status of the GBTS.
5.9.2 Checking the Running Status of the NodeB
You can analysis the NodeB commissioning report to infer the running status of the NodeB.
5.9.3 Checking the Running Status of the eNodeB
You can analysis the eNodeB commissioning report to infer the running status of the eNodeB.
5.9.1 Checking the Running Status of the GBTS
You can analysis the GBTS commissioning report to infer the running status of the GBTS.
Context
NOTE
l
When the status of the GBTS commissioning task is
Waiting for Acknowledgement
, you can infer
that the service verification is complete. The obtained commissioning report can help you determine
the running status of the GBTS.
l
The commissioning report records all the commissioning information generated from the start of the
commissioning task to the moment the report is generated. Therefore, the commissioning report that
records the information about the whole commissioning process can be obtained only when the status
of the GBTS commissioning task is
Finished
, that is, at the end of the GBTS commissioning task.
Procedure
Step 1
View the GBTS commissioning report to infer the running status of the GBTS.
Step 2
View the alarm list and clear the active alarms according to the
BSC6900 GSM Alarm
Reference
.
NOTE
There are two methods of viewing the alarm list:
l
Export the alarm list when the commission report is exported. Then, the commissioning report includes
the alarm list.
l
Open the alarm list window according to step 1 and step 2 in
3900 Series Multi-Mode Base Station
Commissioning Guide
5 Commissioning the MBTS in GL or UL Mode on the
M2000
Issue 02 (2010-07-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5-37