26
Resetting the Password
7.2
1. Ensure that the SUN2000 connects to the AC and DC power supplies at the same time.
Indicators and are steady green or blink at long intervals for more than 3 minutes.
2. Perform the following operations within 3 minutes:
a. Turn off the AC switch and set the DC switch at the bottom of the SUN2000 to OFF.
b. Turn on the AC switch and set the DC switch to ON. Ensure that the indicator is blinking
green at long intervals.
c. Turn off the AC switch and set the DC switch to OFF. Wait until all LED indicators on the
SUN2000 panel are off.
d. Turn on the AC switch and set the DC switch to ON.
a. Wait until the indicator blinks green at long intervals.
b. Obtain the initial WLAN hotspot name (SSID) and initial password (PSW) from the label
on the side of the SUN2000 and connect to the app.
c. On the login screen, set a new login password and log in to the app.
3. Reset the password within 10 minutes. (If no operation is performed within 10 minutes,
all inverter parameters remain unchanged.)
Statement
Customer Service Contact Information
Area
Country/R
egion
Phone
Japan
Japan
0120258367
8
Customer Service Contact Information
2. Connect to the solar inverter WLAN and log in as installer to access the device commissioning
screen.
Log in as installer
user. The initial