5.6 Handling Faults Based on Symptoms
lists the minimum configuration of servers.
Table 5-19 Minimum configuration of servers
Model
Minimum
Configuration
Remarks
RH1288 V3, RH2288 V3,
RH2288H V3, 5288 V3
One CPU in the CPU1
socket
None
One DIMM in the
DIMM000(A) slot
RH8100 V3 (8P)
One CPU in the CPU1
socket
Dual system mode
(one PSU in any slot)
One memory board in
slot 1
One DIMM in the
DIMM000 slot
One HFC board in the
HFC2 slot
RH8100 V3 (dual-system
primary 4P)
One CPU in the CPU1
slot
Dual system primary
4P (one PSU in any
slot)
One memory board in
slot 1
One DIMM in the
DIMM000 slot
One HFC board in the
HFC2 slot
RH8100 V3 (dual system
secondary 4P)
One CPU in CPU5 slot
Dual system
secondary 4P (one
PSU in any slot)
One memory board in
slot 9
One DIMM in the
DIMM000 slot
One HFC board in the
HFC1 slot
RH5885 V3
Two CPUs in the CPU1
and CPU2 sockets
One PSU in any slot
One DIMM in the
DIMM000 slot