Do not twist, bend, stretch, or extrude fibers during installation.
l
Cover the idle fiber connectors with dust caps. Remove the dust caps before using the
fiber connectors.
Requirements for Cable Routing
l
To protect cables, remove the burrs in the cable through-holes or install protective rings
in the holes.
l
To ease the connection and to avoid stress, keep cable joints slack. After connecting
multiple cables to a connector that has multiple interfaces, keep the cables slack to avoid
generating stress.
l
Bind or clean cables gently because cable distortion affects signal quality.
l
Keep cables away from moveable components such as doors.
l
Sharp objects must not touch cable wiring to prevent damage to cables.
l
To protect power cables, route power cables of the active and standby power modules
separately.
6.1.5.2 Installing Power Adapters
6.1.5.2.1 Installing the OT Terminal
Procedure
l
Install an OT terminal.
a.
Align the hole of the OT terminal (conductor upward) with a connecting hole, as
shown in
Figure 6-108
Aligning the OT terminal with a connecting hole
NOTE
When you install an OT terminal, the crimping sleeve is installed as shown in
where A is correct and B is incorrect.