background image

9

 

Chapter 

3

. Attention 

S400W  /  S380WS  Series  Data  Logger  are  not  waterproof.  Do  not  connect  loggers  with

computer when the logger is on water.

S400W / S380WS Series Data Logger plastic shell is ABS, flame retardant, not resistant

to acid and alkali.

If repair is needed, only authorized technician could do the repair.

AA alkaline battery (1.5V) is not rechargeable.

ER14505 lithium battery (3.7V) is not rechargeable.

USB power supply (5V) cannot let the Data Logger work.

Chapter 

4

. FAQ 

4

.1 LCD Screen Dim 

Reason: 

Insufficient battery or the environment temperature is too low or too high.

Solution: 

In the case of insufficient battery, please replace the battery. If resulted from environment

temperature, please immediately take the logger out of the environment.

4

.2 Recording (LOG) are Automatically Stop 

Reason: 

When  the  battery  level  is  low,  there  will  not  be  sufficient  power  to  support  recording

function of the logger.

Solution: 

Replace the battery.

4

.3 Software "Runtime Error" 

Reason: 

OS forbid software creating files.

Solution: 

Run the program (software) as an administrator.

Install software in Disk D:\

A data logger name cannot contain any of the following characters: \ / : * ? " < > |

Software’s installation path cannot include Chinese character or garbage character.

4

.4 Check COM Port Number 

Press  “Win”  +  “R”  in  keyboard  ->  Run  "devmgmt.msc"  to  Open  "Device  Manager"  in

Windows->  Expand  "Ports  (COM  &  LPT)"  ->  "USB-SERIAL  CH340  (COM  No.)"  is  the

Data Logger

Содержание S380WS Series

Страница 1: ...S380WS Series User Manual S380WS...

Страница 2: ...battery 5 Chapter 2 Logpro Software 6 2 1 The Requirement of the Computer Hardware 6 2 2 Install Driver Software 6 2 3 Setting the Logger s Properties 7 2 4 Properties Description 8 Chapter 3 Attenti...

Страница 3: ...erval by software 1 2 Features Logging interval 60 second 6 hours Logging protection Logging will stop when battery is low The value can be saved forever safely Display Resolution temperature 0 1 humi...

Страница 4: ...USB Interface ON OFF Log Wall mounted Back Cover ON OFF Power Power Back Cover 1 5 Screen S380WS Power Symbol DC power Symbol Signal Symbol LOG Recording Status Symbol Wireless Symbol Selectable Symbo...

Страница 5: ...5 1 6 Install battery 1 Take out the back cover as the indication symbol 2 Install 2 x ER14505 3 6V Lithium batteries...

Страница 6: ...1 OS Windows XP Vista 7 8 32 64bit 2 CPU 1 6GHz 3 Physical Memory 512MB 4 Hard drive Space 4 GB 5 USB Port 1 2 2 Install Driver Software 1 Install Driver Notice Windows 64bit please install 64bit dri...

Страница 7: ...fast When unplugging the logger wait for about 5 seconds before plugging it in again If you unplug and plug back a device too quickly the computer may stop recognizing any USB devices on that port If...

Страница 8: ...data Logs The count of records in the memory Total The total capacity of the logger s storage Alarm Turn ON OFF the Data Logger s Over Limit Alarm LCD Please choose ON Power Please choose Normal High...

Страница 9: ...nsufficient battery please replace the battery If resulted from environment temperature please immediately take the logger out of the environment 4 2 Recording LOG are Automatically Stop Reason When t...

Отзывы: