Huasun Wireless H3G-TA Скачать руководство пользователя страница 1

 

                  

 

 

 

 

 

 

 

Wireless H3G-TA 

 

ENGINEERING MANUAL

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Hangzhou Huasu Jada Technology Co., Ltd 

No.16, Xiyuan Wu Road, Westlake Tech-economy Zone, Hangzhou, China 

TEL: 0086-571-87967915  FAX:0086-571-87968969 

www.huasucn.com 

 

 

Содержание Wireless H3G-TA

Страница 1: ...Wireless H3G TA ENGINEERING MANUAL Hangzhou Huasu Jada Technology Co Ltd No 16 Xiyuan Wu Road Westlake Tech economy Zone Hangzhou China TEL 0086 571 87967915 FAX 0086 571 87968969 www huasucn com...

Страница 2: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that int...

Страница 3: ...TC modules 13 3 5 Address Setting For TC modules by CM Module 16 3 6 CT and TC Module Installation 17 3 7 CM Module Installation And Wiring 18 CM module can be mounted in a rack or on the battery rac...

Страница 4: ...M TEL 0571 87967915 1 Tools required for installation and Debugging NO Picture Description Installation tools 1 Socket wrench 12902 Socket head 12307 309 311 2 Multimeter VC9807A 3 Clamp Meters VC3266...

Страница 5: ...Engineering Manual A8 WWW HUASUCN COM TEL 0571 87967915 2 6 Flat head screwdriver 61311 7 Phillips head screwdriver 61211 8 Needle nose pliers 70124A 9 Diagonal pliers 70221A 10 Wire pliers CP 376TR 1...

Страница 6: ...sed of wireless TA module TC module wireless converter and CM module The CM module with LCD display and can upload data through RS485 or network port In remote monitoring a computer can be connected t...

Страница 7: ...logy provides its users with easy step by step installation plans engineering drawings device configuration wiring methods and wiring diagram Installation steps are as follows Check inventory of equip...

Страница 8: ...7915 5 2 System Components and Module Description 2 1 System Components Standard configuration below Part Number Picture Descriptive name 1 TA Module 2 CM Module 3 TC Module 4 Current Transfer CT 5 TA...

Страница 9: ...ingle battery internal resistance and temperature and uploads data via the communications port The TA Module doesn t have an alarm function It is powered by monitored battery The module comes in 2V ty...

Страница 10: ...al resistance and cell temperature The CM Module displays all battery data One CM module can manage up to 6 battery strings and each string is up to 300 batteries The details of functionality are show...

Страница 11: ...Tx5 corresponds with COM2 COM3 COM4 and COM5 Ground Connects to the ground Power switch Controls CM Module power input Power Input 100 240VAC input less than 15W for each CM module For future Dry Con...

Страница 12: ...urrent transformer and the ambient temperature sensor LED A double colors LED with a red and green light the green light indicates power on the red shows that communication is connected COM1 COM2 port...

Страница 13: ...rt It s a 4 core for collecting the pins of COM1B COM4B on CM module From the left are B A where B is of RS485 A is of RS485 baud rate is 9600BPS is a 12VDC input with maximum 0 3W power dissipation L...

Страница 14: ...The first battery or battery NO 1 must be the first one on the string positive terminal the NO 2 is the battery following the NO 1 battery and so on The last battery is the one attached closest to the...

Страница 15: ...o install between the battery pole and the connection bar The following details are shown below Figure 3 2 2 Notice After all installation work is completed each battery pole screw tightness must be c...

Страница 16: ...he second group TA addresses are set from 1 to 32 TC is 241 Address Setting For TA Module Turn on the side switch and press the ESC button then set the address by button press Enter button to H A inte...

Страница 17: ...module port number needs to be consistent with the wireless converter port number Figure 3 4 1 Modification method of wireless converter port number The wiring diagram is as follows Opening serial por...

Страница 18: ...Module address and port number setting by serial port Software Set the 32 batteries of each group and total 2 strings as an example In the first group the TA addresses are set from 1 to 32 and the add...

Страница 19: ...ber 3 5 Address Setting For TC modules by CM Module Connecting COM1 or COM2 port of the TC module to the COM1A port of the CM module and the COM1B port cannot be connected to the wireless converter Po...

Страница 20: ...and let the cable go through the CT Figure 3 5 1 Keep the direction same between it showed on the CT and charge current flows Figure 3 5 2 The TC module can be mounted on the battery rack near the CT...

Страница 21: ...ing CM module can be mounted in a rack or on the battery rack as below Figure 3 6 1 Figure 3 6 2 The CM module combine with wireless converter to communicate with TA and connecting TC modules via the...

Страница 22: ...Wireless H3G TA Engineering Manual A8 WWW HUASUCN COM TEL 0571 87967915 19...

Страница 23: ...d basic information for each string then CM module will set the rest parameters automatically But resistance base values for each battery should be set manually please follow the instructions in anoth...

Страница 24: ...the menu B Alarm Info B 1 Curr Alm Choose a string Use or to see all alarms In the menu B 2 Alarm Rec all recovered alarms will be showed During alarming the buzzer in CM module will turn on and pres...

Страница 25: ...to check the repeating accuracy Perform IR test for 3 times and calculate the repeating accuracy For most applications 5 is acceptable for IR repeating accuracy In some projects customers will requir...

Страница 26: ...et in the menu 3 5 Str Set the cycle number can be changed to one bigger than 10 Changing IR interval time Every month IR test will be performed automatically which can be changed to one day or severa...

Страница 27: ...HUASUCN COM TEL 0571 87967915 24 Click Reset BMS After reloading the web enter admin in the User ID blank and 2022 in the Password blank Choose a new firmware file and click Upload The updating proce...

Страница 28: ...the last 100 alarm records B 1 Curr Alm Not recovered alarms B 2 Alarm Rec recovered alarms C Setup Set all parameters 1 Easy Setup A easy way to set all parameters 2 R Test Perform a resistance manua...

Страница 29: ...es in internal resistance so the measured internal resistance does not necessarily mean that the battery performance changes Records A0 20130124 Distribution edition A1 20130801 Added TA and TC module...

Отзывы: