Beijing Huahuan Electronics Co., Ltd
Step 2
Plug the RJ12 connector into the RJ12 socket on the GeckoSynco.
Step 3
Secure the cables at a nearby location.
Step 4
Connect the other end to the 1PPS+ToD input of the timing client.
The connector and signal definition of the client equipment must be
consulted. Make sure the polarity of the differential RS-422 signals
must be matched
4.3.
Setting Operating Parameters
See Section 6
Software Usage for details.
5
5
.
.
D
D
e
e
v
v
i
i
c
c
e
e
M
M
a
a
n
n
a
a
g
g
e
e
m
m
e
e
n
n
t
t
HX.PTP-GM02 can be managed through CLI commands, a web browser, or
a SNMP manager. All three methods use the Ethernet port to communicate with
the device.
To manage the device, a valid unique local IP must be allocated to it first.
The factory default IP address is 192.168.1.2, which can be used to access the
device to set its permanent IP address. Use a laptop with dynamic IP setting so
that it is a DHCP client. Press down the dip-2 on the GeckoSynco and it becomes
a DHCP server with the default IP. Connect the Ethernet cable from the laptop to
the Data/IN socket on the PoE adaptor as the laptop is unlikely a PSE. Ping the
default IP to verify correct connection. Use CLI or web browser through the
default IP to set the allocated IP address to the device. Lift up the dip-2, and the
device is ready to be managed through the new IP address.
Web server and CLI interface are described in the next chapter. Users who
need to use SNMP management may request MIB from Huahuan
.
22 HX.PTP-GM02 IEEE-1588 Grandmaster Clock V1.0