lp-730 Rev. 000 Rel. 000 Date 11.26.19
6
NOTE: TANK RECOVERY FROM COLD START WILL BE BETWEEN 10-13 MINUTES WHEN SIZED WITH CORRECT FLOW RATE, BOILER SIZE AND
PRESSURE DROP RATINGS FROM LIST IN ABOVE CHART.
*DOE TEST METHOD BASED ON 90 F TEMPERATURE RISE, 50 /140 W/BOILER WATER AT 180 F
LP-730-A
11/26/19
SUPERSTOR ULTRA
MODEL HEAT EXCHANGER
SURFACE/VOLUME
PRESSURE
DROP (FT.)
TEST
PRESSURE
WORKING
PRESSURE
180 BOILER
WATER FIRST
HOUR RATINGS
(GAL) *
200 BOILER
WATER FIRST
HOUR RATINGS
(GAL) *
180 F
BOILER
BTU/SIZE
200 F
BOILER
BTU/SIZE
RECOMMENDED
FLOW RATE
140 F 115 F 140 F 115 F
SSU-20N
15 SQ. FT./1.,5 GAL.
6.0
300 PSI
150 PSI
121
168
136
185
84,000
87,000
8
SSU-30N
154
212
172
234
102,000
117,000
SSU-30LBN
169
234
189
257
114,000
131,000
SSU-45N
20 SQ. FT./2.0 GAL.
7.9
212
292
237
322
141,000
161,000
10
SSU-60N
266
370
298
405
174,000
198,000
SSU-80N
34 SQ. FT./3.0 GAL.
9.1
330
440
370
503
212,000
241,000
12
SSU-119N
11.3
423
564
474
645
269,000
301,000
14
SUPERSTOR ULTRA COMMERCIAL
MODEL
HEAT EXCHANGER
SURFACE/VOLUME
PRESSURE
DROP (FT.)
TEST
PRESSURE
WORKING
PRESSURE
180 BOILER
WATER FIRST
HOUR RATINGS
(GAL) *
200 BOILER
WATER FIRST
HOUR RATINGS
(GAL) *
180 F
BOILER
BTU/SIZE
200 F
BOILER
BTU/SIZE
RECOMMENDED
FLOW RATE
140 F 115 F 140 F 115 F
SSU-45CN
40 SQ. FT./4.0 GAL.
6.8
300 PSI
150 PSI
314
414
351
477
215,000
246,000
20
SSU-60CN
9.2
354
467
396
539
245,000
270,000
22
SSU-80CN
68 SQ. FT./6.0 GAL.
10.0
490
647
548
745
331,000
374,000
24
SSU-119CN
12,7
637
841
713
970
425,000
490,000
28
SUPERSTOR ULTRA DOUBLEWALL
MODEL
HEAT EXCHANGER
SURFACE/VOLUME
RECOMMENDED
FLOW RATE
(GPM)
PRESSURE
DROP (FT.)
TEST
PRESSURE
180 BOILER
WATER FIRST
HOUR RATINGS
(GAL) *
200 BOILER
WATER FIRST
HOUR RATINGS
(GAL) *
180 F
BOILER
BTU/SIZE
140 F 115 F 140 F 115 F
SSU-45DWN
15 SQ.FT/1.5 GAL
6
8.2
300 PSI
40
63
70
108
107,000
SSU-60DWN
7
12.8
50
76
90
144
176,000
SSU-80DWN
10
13.6
72
113
138
215
208,000
SSU-119DWN
12
15.9
110
171
210
326
231,000
Table 2 - Specifications
Continuous Flow Performance Calculation
First Hour Rating - (.75 X Tank Capacity) = Continuous Flow
Example: SSU-45CN = 314 - (.75 X 45) = 280.25
B. Performance and Sizing Guidelines
NOTE:
The table below describes the minimum BTU/H required to achieve the listed first hour rating.
MODEL
GROSS BOILER OUTPUT
140
o
F
90
o
F Δ T
127
o
F
77
o
F Δ T
115
o
F
65
o
F Δ T
SSU-20N
84,000
121
140
168
SSU-30N
102,000
154
180
212
SSU-30LBN
113,000
169
198
234
SSU-45N
141,000
212
248
292
SSU-45CN
215,000
314
367
414
SSU-60N
174,000
266
311
370
SSU-60CN
245,000
354
414
467
SSU-80N
212,000
330
386
440
SSU-80CN
331,000
490
573
647
SSU-119N
269,999
423
495
564
SSU-119CN
425,000
637
745
841
Table 3 - Water Heater Performance and Sizing Guidelines