12
LP- 325 REV. 3.3.15
3” Polypro Pipe (33’ length Part # 8400P-002, 49.5’ length Part # 8400P-003)
U.L. 353 Compliant Low Water Cut-Off Interface Kit with Manual Reset (Part # 7350P-601)
Alarm System (Part # 7350P-602) (to monitor any failure)
PC Connection Kit (Part # 7250P-320)
Condensate Neutralizer (Part # 7450P-212)
Vision 2 Temperature Mixing Control (Part # 7250P-322)
These additional options may be purchased through your HTP distributor.
NOTE:
When using an optional system sensor, pipe insulation must be wrapped around it to improve temperature measurement
accuracy and increase overall system efficiency.
PART 3 – PREPARE APPLIANCE LOCATION
Carefully consider installation when determining appliance location. Please read the entire manual before attempting installation.
Failure to properly take factors such as appliance venting, piping, condensate removal, and wiring into account before installation could
result in wasted time, money, and possible property damage and personal injury.
A. BEFORE LOCATING THE APPLIANCE
Incorrect ambient conditions can lead to damage to the heating system and put safe operation at risk. Ensure that the appliance
installation location adheres to the information included in this manual. Failure to do so could result in property damage, serious
personal injury, or death.
Failure of appliance or components due to incorrect operating conditions IS NOT covered by product warranty.
1. Installation Area (Mechanical Room) Operating Conditions
Ensure ambient temperatures are higher than 32
o
F/0
o
C and lower than 104
o
F/40
o
C.
Prevent the air from becoming contaminated by the products, places, and conditions listed in this manual, Part 3, Section F.
Avoid continuously high levels of humidity
Never close existing ventilation openings
Ensure a minimum 1” clearance around hot water and exhaust vent pipes
The service life of the appliance
’s exposed metallic surfaces, as well as internal surfaces, such as the heat exchanger, are directly
influenced by proximity to damp and salty marine environments. In such areas, higher concentration levels of chlorides from sea spray
coupled with relative humidity can lead to degradation of the heat exchanger and other appliance components. In these environments,
appliances must not be installed using direct vent systems which draw outdoor air for combustion. Such appliances must be installed
using room air for combustion. Indoor air will have a much lower relative humidity and, hence, potential corrosion will be minimized.
This appliance is certified for indoor installations only. Do not install the appliance outdoors. Failure to install this appliance indoors
could result in substantial property damage, severe personal injury, or death.
2. Check for nearby connections to:
System water piping
Venting connections
Gas supply piping
Electrical power
Condensate drain
3. Check area around appliance. Remove any combustible materials, gasoline, and other flammable liquids.
Failure to keep appliance area clear and free of combustible materials, liquids, and vapors can result in substantial property damage,
severe personal injury, or death.
Содержание Pioneer
Страница 17: ...17 LP 325 REV 3 3 15 Figure 3 Dimensions ...
Страница 28: ...28 LP 325 REV 3 3 15 Figure 9 DHW Pack Performance on 199K BTU Models ...
Страница 44: ...44 LP 325 REV 3 3 15 Figure 20 ...
Страница 47: ...47 LP 325 REV 3 3 15 Figure 22 Internal Wiring Diagram ...
Страница 67: ...67 LP 325 REV 3 3 15 Figure 30 Pioneer and Versa Flame ...
Страница 68: ...68 LP 325 REV 3 3 15 Figure 31 Pioneer and Versa Flame ...
Страница 71: ...71 LP 325 REV 3 3 15 ...
Страница 72: ...72 LP 325 REV 3 3 15 ...