PART 3 – HEATER PIPING 

A. PLUMBING 

It is mandatory that all plumbing be done in accordance with federal, local, and state plumbing codes and practices. Failure to properly 
install the water heater WILL VOID the warranty. It is also necessary to use both thread tape and pipe dope on all mechanical plumbing 
connections. 
 
Use unions on the hot and cold water connections and the relief valve discharge line, so that the heater may be easily disconnected for 
servicing when necessary. 
 

 

Use two wrenches when tightening water piping at the heater. Use one wrench to prevent the heater return and supply lines from 
turning. Failure to prevent piping connection from turning could cause damage to heater components. 
 

 

Dielectric unions or galvanized steel fittings must not be used in a system with this water heater. Use only copper or brass fittings. 
Teflon thread sealant must be used on all connections. 
 
1. Connect the cold water supply line to the connection marked “COLD” near bottom of heater. Refer to “Typical Installation”, Figure 3. 
 
2. Install a shut-off valve and a drain valve (field supplied, not supplied with the heater) in the cold water line near the heater. 
 
3. Connect hot water line to the connection marked “HOT” on side near the top of the heater. 
 
4. An opening is provided near the top of the heater for installation of a Temperature and Pressure Relief Valve (T&P Valve). 

B. TEMPERATURE AND PRESSURE RELIEF VALVE 

NOTE: 

For protection against excessive pressures and temperatures in this water heater, install temperature and pressure protective 

equipment as required by local codes, but not less than a combination T&P valve meeting the requirements for 

Relief Valves and 

Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22B / CSA 4.4-M99

, by a nationally recognized testing 

laboratory that maintains periodic inspection of production of listed equipment and materials. 
 
Install the T&P valve into the opening provided and marked for this purpose on the water heater so that discharge water from the valve 
will not come in contact with any live electrical parts. 
 

 

Do not thread a cap or plug into the relief valve under any circumstances! Explosion and property damage, serious injury, or death may 
result. 
 

 

To avoid water damage or scalding due to relief valve operation: 

 

Discharge line must be connected to relief valve outlet and run to a safe place of disposal. Terminate the discharge line in a 
manner that will prevent possibility of severe burns or property damage should the relief valve discharge. 

 

Discharge line must be as short as possible and the same size as the valve discharge connection throughout its entire length. 

 

Discharge line must pitch downward from the valve and terminate at least 6” above the floor drain, making discharge clearly 
visible. 

 

The discharge line shall terminate plain, not threaded, with a material serviceable for temperatures of 375

o

F or greater. 

 

Do not pipe discharge to any location where freezing could occur. 

 

No shutoff valve may be installed between the relief valve and heater or in the discharge line. Do not plug or place any 
obstruction in the discharge line. 

 

Test the operation of the relief valve after filling and pressurizing the system by lifting the lever. Make sure the valve 
discharges freely. If the valve fails to operate correctly, immediately replace with a new properly rated relief valve. 

 

Test T&P valve at least once annually to ensure the waterway is clear. If valve does not operate, turn the heater “off” 

and call 

a plumber immediately.

 

 

Take care whenever operating relief valve to avoid scalding injury or property damage. 

FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION, 
RESULTING IN POSSIBILITY OF SUBSTANTIAL PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH. 

 

Содержание Everlast EV-12

Страница 1: ...oduct contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm NOTICE HTP reserves the right to make product changes or updates without notice and w...

Страница 2: ...rety before beginning any work Installation should be made in accordance with the regulations of the Authority Having Jurisdiction local code authorities and utility companies which pertain to this ty...

Страница 3: ...ble materials 0 top bottom sides and back Heater must have room for service 24 front and 6 sides are minimum recommended service clearances A combustible door or removable panel is acceptable front cl...

Страница 4: ...CA 95814 or you may call 916 324 5315 or ask a water heater dealer However applicable local codes shall govern installation For residential water heaters of a capacity greater than 52 gallons consult...

Страница 5: ...22 27 19 41 EV 30 30 4500 240 4 34 39 19 55 EV 30LB 30 4500 240 4 21 28 23 65 EV 45LB 45 4500 240 4 34 42 23 86 EV 50 50 4500 240 4 56 63 19 1 90 EV 80 80 4500 240 5 64 72 23 1 132 Table 1 Specificat...

Страница 6: ...result in substantial property damage severe personal injury or death 2 Check for nearby connections to System water piping Electrical power Choose a location for the water heater as centralized to th...

Страница 7: ...testing laboratory that maintains periodic inspection of production of listed equipment and materials Install the T P valve into the opening provided and marked for this purpose on the water heater so...

Страница 8: ...cold and hot water in branch supply lines Such valves are available from your local plumbing supplier Table 2 details the relationship of water temperature and time with regard to scald injury and ma...

Страница 9: ...REV 4 15 14 F INSTALLATION DIAGRAMS Figure 3 Piping Detail NOTE Drawing is meant only to demonstrate system piping concept The installer is responsible for all equipment and detailing required by loca...

Страница 10: ...V 4 15 14 Figure 4 Mobile Home and Point of Use Piping Detail NOTE Drawing is meant only to demonstrate system piping concept The installer is responsible for all equipment and detailing required by l...

Страница 11: ...the 120 volt model the white wire must be connected to the neutral leg 240V electrical installation should be done by a qualified licensed electrician or by your local electric utility All wiring mus...

Страница 12: ...protective cover should NOT be removed Set temperature indicator to desired temperature Replace insulation and the black access cover Turn on power to the heater See below for Thermostat adjustment E...

Страница 13: ...Screw the element clockwise into tank and tighten with the 1 socket wrench Be sure O ring seats properly STEP 6 Refill the tank with cold water STEP 7 Pressure check the tank for leaks around element...

Страница 14: ...for assistance Check the area around the water heater for flammable liquids or combustible materials If any are found remove from the area Vacation Extended Shut Off Periods During extended mild or w...

Страница 15: ...at 4 Manual Reset High Limit Switch ECO open a Thermostat s defective b Thermostat out of calibration c Heat build up due to loose wires d Defective High Limit Switch ECO 1 Turn switch ON 2 Rewire per...

Страница 16: ...LECTRIC ELEMENT W O RING EV 6 EV 20 1 2 6060P 187 ELECTRICAL BOX COVER 2 3 TP1500 3 4 T P VALVE 100XL 8 1 4 6060P 633 THERMODISC MOUNTING CLIP 2 5 TD1015 UPPER THERMOSTAT CONTROL 1 6 6060P 1009 THERMO...

Страница 17: ...17 LP 04 REV 4 15 14 NOTES...

Страница 18: ...nstallation Address Date of Installation Installer s Code Name Product Serial Number s Comments Installer s Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign afte...

Отзывы: