lp-657 Rev. 001 Rel. 000 Date 12.10.18
7
C. Optional Equipment
Optional equipment available from HTP (and Part #):
• System Sensor (7250P-324)
• 3” PVC Concentric Vent Kit (KGAVT0601CVT)
• 3” Stainless Steel Vent Termination Kit (V1000)
• 4” Stainless Steel Vent Termination Kit (V2000)
• 6” Stainless Steel Vent Termination Kit (V3000)
• 3” Polypro Vent Kit (8400P-001)
• 3” Polypro Pipe
(33’ length # 8400P-002, 49.5’ length # 8400P-003)
• UL 353 Compliant Low Water Cut-Off Interface Kit with Manual
Reset (7600P-990)
• Manual Reset High Limit (7450P-217)
• Alarm System (to monitor any failure) (7350P-602)
• PC Connection Kit (7250P-320)
• Condensate Neutralizer (285 Model - 7450P-212, 399 Model -
7350P-611)
• Condensate Removal Pump (554200)
• Flow Switch Kit (7450P-213)
• Fuel Conversion Kit (285 Model - LP to NG - 7600P-890, NG to
LP 7600P-891)
• Fuel Conversion Kit (399 Model - LP to NG - 7600P-892, NG to
LP 7600P-893)
NOTE:
When using an optional system sensor, pipe insulation must be
wrapped around it to improve temperature measurement accuracy
and increase overall system efficiency.
further enhanced by installing an indirect water heater to provide
domestic hot water.
The control can regulate the output of multiple boilers through
its cascade system function. The cascade system is capable of
connecting up to eight boilers together in such a way that they
function as one boiler system. This allows for greater turn down
ratios and provides systematic control of the multiple boilers in an
installation to minimize downtime and maximize efficiency.
The cascade system works by establishing one boiler as the master
and the other connected boilers as followers. The master boiler
requires a sensor to provide feedback on set point temperature
in order to adjust heating input from the connected boilers. Each
cascaded boiler will have its own pump to provide maximum flow
and control heat exchanger flow rate.
Text Display and Operational LED Light Indicators
The display allows the user to change system parameters and
monitor system outputs.
Gas Valve
Senses suction from the blower, allowing gas to flow only if powered
and combustion air is flowing.
All Metal Integrated Venturi
Controls air and gas flow into the burner.
Burner
The high grade stainless steel burner uses premixed air and gas to
provide a wide range of firing rates.
Spark Ignition
The burner is ignited by applying high voltage through the system
spark electrode. The spark from the electrode ignites mixed gas off
of the burner.
Supply Water Temperature Sensor
This sensor monitors the boiler outlet water temperature (System
Supply). The control adjusts boiler firing rate so the supply
temperature will match the boiler set point.
Return Water Temperature Sensor
This sensor monitors boiler return water temperature (System
Return).
Flue Sensor
Monitors flue temperature and adjusts firing rate.
Temperature and Pressure Gauge
Allows the user to monitor system temperature and pressure.
Electrical field connections with terminal strips
The electrical cover allows easy access to the clearly marked line
voltage and low voltage terminal strips to facilitate wiring the boiler.
Condensate Collection System
This boiler is a high efficiency appliance and will produce condensate.
The condensate collection system has a float switch which monitors
condensate level and prevents condensate from backing up into
the combustion system. Inside the collection system is a built in trap
which seals the combustion system from the connected drain. This
condensate should be neutralized to avoid damage to the drainage
system or piping.
Outdoor Sensor
Monitors outdoor temperature and adjusts unit set point to provide
greater efficiency.
0-10 Volt Input
Allows the installer to connect a BMS (Building Management
System) to control the boiler.
Condensate Flue Check System
The check system prevents heat exchanger exhaust from backing
up into the cabinet.
Pump Service Mode
Allows manual operation of pumps to commission system and
check pump operation.
Part 3 - Prepare the Boiler
COLD WEATHER HANDLING
- If the boiler has been stored in a very
cold location (BELOW 0
o
F) before installation, handle with care until
the components come to room temperature. Failure to do so could
result in damage to the boiler.
Carefully consider installation when determining boiler location.
Please read the entire manual before attempting installation. Failure
to properly take factors such as boiler venting, piping, condensate
removal, and wiring into account before installation could result in
wasted time, money, and possible property damage and personal
injury.
Remove all sides of the shipping crate, and the wooden block that
holds the boiler in place during shipping. Slide the boiler from the
mounting bracket, which is affixed to the skid (Figure 1 and 2). Remove
the mounting bracket from the crate (Figure 1). Take care to place the
boiler in a safe location prior to installation to prevent damage to the
mechanical connections.
Figure 1 - Pallet with Affixed Mounting Bracket
Содержание Elite FT EFT-285
Страница 22: ...lp 657 Rev 001 Rel 000 Date 12 10 18 22 Figure 9 Piping Symbol Legend ...
Страница 41: ...lp 657 Rev 001 Rel 000 Date 12 10 18 41 Figure 31 Internal Connection Diagram ...
Страница 66: ...lp 657 Rev 001 Rel 000 Date 12 10 18 66 Figure 36 Cabinet Replacement Parts ...
Страница 69: ...lp 657 Rev 001 Rel 000 Date 12 10 18 69 Maintenance Notes ...