LP-644 Rev. 8.10.17
4
Table of Contents
Part 1 - General Safety Information
4
A. Operation and Installation Warnings
4
B. Improper Combustion
6
C. Gas
6
D. When Servicing the Water Heating System
6
E. Water Chemistry Requirements
6
F. Freeze Protection
6
G. Water Temperature Adjustment and Scalding
7
H. High Elevation Installations
7
Part 2 - Before You Start
8
A. What’s in the Box
8
B. Optional Equipment
8
Part 3 - Prepare the Water Heater Installation
9
A. Locating the Water Heater
9
B. Leveling
10
C. Clearances for Service Access
10
D. Residential Garage and Closet Installations
10
E. Exhaust Vent and Intake Pipe
10
1. Direct Vent of Exhaust and Intake
11
2. Power Venting, Indoor Combustion Air in Confined or Unconfined Space
11
F. Carbon Monoxide Detectors
11
G. Prevent Combustion Air Contamination
11
H. Removing a Heater from a Common Vent System
12
I. Technical Specifications
13
J. Wall-Mounting
17
Part 4 - Water Piping
18
A. General Plumbing Guidelines
18
B. Backflow Preventer
18
C. Potable Expansion Tank
18
D. Piping the Water Heater
18
E. Applications
19
F. Circulator Sizing
23
G. Pressure Relief Valve
23
H. Filling the Heater
24
Part 5 - Venting
24
A. General
24
B. Approved Materials for Exhaust Vent and Intake Pipe
25
C. Additional Requirements for Installation in Canada
26
D. Exhaust Vent and Intake Pipe Location
27
E. Exhaust Vent and Intake Pipe Sizing
28
F. Tightening Water Heater Collar to Exhaust Vent and Intake Pipe 28
G. Exhaust Vent and Intake Pipe Installation
28
H. Applications
29
1. Direct Vent Installation of Exhaust and Intake
29
2. Venting Through an Existing System
32
3. Power Venting, Indoor Combustion Air in Confined or Unconfined Space
33
I. Common Vent Piping
34
1. Vent Diameter Sizing and Lengths
34
2. Recommended Exhaust Pipe Transitions
35
3. Two (2) Pipe Common Direct Vent Systems
35
Part 6 - Installing the Condensate Drain
37
Part 7 - Connecting Electrical Service
38
A. Wiring
38
B. Dip Switches
38
C. Wiring a Cascaded System
39
Part 8 - Gas Connections
43
A. Gas Pipe Sizing Tables
43
1. Gas Pipe Sizing
43
2. Natural Gas Pipe Sizing
43
3. LP (Liquid Propane) Gas Pipe Sizing
44
B. Gas Connection Requirements
44
C. Additional Precaution for Excess Flow Valve (EFV)
44
D. Checking Gas Pressure at the Water Heater for Proper Operation
44
E. Setting and Verifying the Combustion Setting
44
Part 9 - Controls
45
A. Control and Display Overviews
45
B. Start-Up Sequence
46
C. Changing the DHW Set-Point
46
D. Changing the Time
46
E. Status Display
47
F. Installer Mode
48
G. Setting Up a Cascaded System
49
H. 0-10 Volt Input
50
Part 10 - Troubleshooting
51
A. Error Code
51
B. Error Tree Analysis
54
1. Flame Detection
54
2. Air Pressure Switch Detection
54
3. Inlet / DHW / Operating Temperature / Exhaust Sensors
55
C. Suggested Corrective Actions
55
Part 11 - Start-Up
56
A. Check / Control Water Chemistry
56
B. Check for Gas Leaks
57
C. Fill and Test Water System
57
D. Condensate Removal
57
Part 12 - Installation Checklist
58
Part 13 - Maintenance
60
Part 14 - Replacement Parts
63
Limited Warranty for CGH-199 Water Heaters
67
Notes 69
Customer Installation Record Form
70
Part 1 - General Safety Information
This water heater is approved for indoor installations only and is not
intended for use as a pool heater. Clearance to combustible materials:
0” top, bottom, sides, and back. Heater must have room for service:
24” front, 3” left and right sides, 18” top, 12” bottom, and 0” back are
minimum recommended service clearances. (A combustible door
or removable panel is acceptable front clearance. A 3” minimum
clearance must be provided from the appliance front cover to the
removable panel or combustible door.) This water heater has been
approved for closet installation and installation on combustible
flooring. Do not install directly on carpeting. Install the water heater
in a location where temperature and pressure relief valve discharge
or a leak will not result in damage to the surrounding area. If such a
location is not available, install an auxiliary catch pan. The appliance
is rated Category IV (pressurized vent, likely to form condensate in
the vent) and requires a special vent system designed for pressurized
venting. Use only Category IV vent systems.
Installer -
Read all instructions in this manual before installing.
Perform steps in the given order.
User -
This manual is for use only by a qualified heating installer
/ service technician. Have this water heater serviced / inspected
annually by a qualified service technician.
FAILURE TO ADHERE TO THE GUIDELINES ON THIS PAGE
CAN RESULT IN SUBSTANTIAL PROPERTY DAMAGE, SEVERE
PERSONAL INJURY, OR DEATH.
NOTE:
Obey all local codes. Obtain all applicable permits before
installing the water heater.
NOTE:
Install all system components and piping in such a manner
that does not reduce the performance of any fire rated assembly.
A. Operation and Installation Warnings
To avoid serious injury or death, read, understand, and follow all of
the precautions listed here.
Содержание CGH-199*
Страница 40: ...LP 644 Rev 8 10 17 40 Figure 38 Electrical Wiring Diagram...
Страница 41: ...LP 644 Rev 8 10 17 41 Figure 39 Ladder Diagram...
Страница 69: ...LP 644 Rev 8 10 17 69 Notes...