background image

Installation Instructions for Rack System 

Main Rack Part # 7866P-017; Extension Rack Part # 7866P-018

272 Duchaine Blvd.

New Bedford, MA 02745

1(800) 323-9651

lp-674 Rev. 5.7.18

STOP! Follow these instructions or warranty will be void!

Installation Must Comply With:

1. The National Fuel Gas Code, ANSI Z223.1, latest edition

2. National Electrical Code

3. In Canada, CSA C22.1 Canadian Electrical Code Part 1, and 

CGA No. B149 (latest version)

4. Local, state, provincial, and national codes, laws, regulations, 

and ordinances.

This installation shall be done by a qualified service agency 

in accordance with these instructions, the installation manual 

included with the appliance to be mounted on this rack, all 

applicable codes, and requirements of the authority having 

jurisdiction. Failure to follow these instructions could result in 

substantial property damage, severe personal injury, or death.

Included with Kit:

Description

Part Number

Quantity

Main Rack Extension Rack

Base Foot

7866P-001

2

1

Base Support

7866P-002

4

2

Angle Support

7866P-003

4

2

Vertical Post

7866P-004

2

1

Lower Beam

7866P-006

1

1

Upper Beam

7866P-007

1

1

End Cap

7866P-009

2

1

M10 Washer

7866P-010

44

24

M10 Hex Screw

7866P-011

22

12

M10 Hex Nut

7866P-012

22

12

M6 Self Tapping 

Screw

7866P-013

12

6

M6 Hex Screw

7866P-014

2

2

M6 Hex Nut

7866P-015

2

2

M6 Washer

7866P-016

4

4

Instructions

LP-674

1

Tools Required (Not Included):

7mm and 10mm Ratchet, Socket Driver, or Wrench

Phillips Head Screwdriver

Rubber Mallet

Appropriate Drill with Assorted Bits

M10 or 7/16” Lag or Anchor Bolts and Washers for Anchoring 

Rack into Wood or Concrete

Preparing for Installation:

Determine the best area to install the rack system. Ensure the 

location meets building code requirements, and that all safety and 

clearance requirements for the appliance(s) to be mounted to the 

rack are met.

Installing the Rack System:

1. Move the rack components to the installation location. Ensure 

you have all the components for the installation.

NOTE: 

DO NOT lose these components. Replacements ARE NOT 

included in this kit.

2.  Set  the  base  feet  in  the  installation  location.  Verify  finished 

installation clearances will meet the service clearance requirements 

of the appliance(s) to be mounted on the rack.

3. Use a Phillips Head Screwdriver and eight (8) screws to install 

the four (4) angle supports to the two (2) base feet. See Figure 1.

NOTE:

 DO NOT fully tighten the screws. Doing so will make it 

difficult to install the vertical posts and waste time.

Remove all items from the packaging and ensure that all parts 

and accessories are included in the kit. Any claims for damage 

or shortage in shipment must be filed immediately against the 

transportation company by the consignee.

Installer - 

Read all instructions in this manual before installing. 

Perform steps in the given order.

 

Obey all local codes. Obtain 

all applicable permits before installing this rack system.

NOTE: 

Install all components in such a manner that does not 

reduce the performance of any fire rated assembly.

User -

  These  instructions  are  for  use  only  by  a  qualified 

heating installer / service technician. 

FAILURE TO ADHERE TO THE GUIDELINES ON THIS 

PAGE CAN RESULT IN SUBSTANTIAL PROPERTY 

DAMAGE, SEVERE PERSONAL INJURY, OR DEATH.

Carefully consider installation when determining rack location. 

Please read the entire appliance installation manual before 

installing this rack. Failure to properly take factors such as 

appliance venting, piping, condensate removal, and wiring into 

account before installation could result in wasted time, money, 

and possible property damage and personal injury.
Do not attempt to overtighten any of the bolts as this may damage 

the threads and prevent the bolts from turning. Replacement 

bolts are not included in this kit.

This rack system must be properly anchored and secured to the 

floor BEFORE mounting appliances on it. Failure to follow these 

instructions could result in substantial property damage, severe 

personal injury, or death.

Содержание 7866P-017

Страница 1: ...omponents to the installation location Ensure you have all the components for the installation NOTE DO NOT lose these components Replacements ARE NOT included in this kit 2 Set the base feet in the installation location Verify finished installation clearances will meet the service clearance requirements of the appliance s to be mounted on the rack 3 Use a Phillips Head Screwdriver and eight 8 scre...

Страница 2: ... Ensure you have all the components for the installation NOTE DO NOT lose these components Replacements ARE NOT included in this kit 2 Set the base foot in the installation location Verify finished installation clearances will meet the service clearance requirements of the appliance s to be mounted on the rack 3 Use a Phillips Head Screwdriver and four 4 screws to install the two 2 angle supports ...

Страница 3: ...and in the installation location 2 Once properly positioned use a pencil to mark the drill holes for the lag screws expansion anchors Then move away the stand 3 Prepare to drill holes into the mounting surface either 4 thick minimum Wood Structural Member or 4 thick minimum Concrete Flooring Consult lag screw or expansion anchor manufacturer for predrill diameters 3 After taking appropriate precau...

Страница 4: ...lp 674 Rev 5 7 18 4 Figure 11 Mounted Single Appliance Figure 12 Mounted Back to Back Appliances Figure 13 Mounted Side by Side Appliances Possible with Extension Rack ...

Отзывы: