d. The criteria of Newton ring's tinges and measure of area must follow up the worst-case sample.
6.2 Display inspection
Inspection Defects
Accept Level
Level
Single
Red+ Green+ Blue
≦
3, S > 5mm.
Minor
2 adjacent
0
Minor
Bright Dots
3 or more adjacent
0
Minor
Single
Total Number
≦
2, S > 5mm.
Minor
Dark Dots
2 adjacent
0
Minor
Dark or Bright lines
0
Minor
All Allowable Dots Defects
Total Number
≦
3, S > 5mm.
Minor
Electrical
Characteristic
Defects
Shift and tilt of screen viewed area
The black edge around display area must be
detected by front view.
Minor
Scratch
0.03 < W
≦
0.1 (mm)
L
≦
5 (mm), N
≦
2 (mm)
Minor
Lint (linear foreign objects)
0.03 < W
≦
0.1 (mm)
0.3 < L
≦
3.0 (mm)
N
≦
5
Minor
Spots
0.1 < D
≦
0.3 (mm), N
≦
4
Minor
Fish eye on film
0.1 < D
≦
0.4 (mm), N
≦
4
Minor
Breakage on film surface
Not acceptable
Minor
Foreign Scratch,
Objects or Lint
on power off
status
Total acceptable defect quantity
≦
10
Minor
6.3 Main unit inspection
GAP & STEP INSPECTION
DESCRIPTION
ACCEPT CRITERIA
LEVEL
1
GAP BETWEEN ALL GENERIC ME PARTS
< 0.4 MM
MINOR
2
GAP BETWEEN TOUCH WINDOW AND A PARTS
< 0.3 MM
MINOR
3
STEP BETWEEN MATING PARTS
< 0.3 MM
MINOR
IT IS GENERIC COSMETIC INSPECTION CRITERIA FOR ALL PRODUCTS IF THERE HAVE ANY CONFLICT
WITH THESE GENERIC CRITERIONS; PLEASE FOLLOW THE PRODUCT INSPECTION CRITERIA