CM-2007 Digital Clamp Meter 

Manual 

This meter is precise equipment. Please read this manual 

carefully before any operation to avoid any damage to you and 

the meter. 

   

   

CONTENT 

SUMMARY

………………………

SAFETY NOTICE

………………………

GENERAL FEATURES

…………………………

1

 

TECHNICAL FEATURES

…………………………

1

 

PANEL DESCRIPTION

…………………………

1

 

OPERATION INSTRUCTIONS

…………………………

DCV MEASUREMENT

…………………

ACV MEASUREMENT

…………………

ACA MEASUREMENT

…………………

RESISTANCE MEASUREMENT

………………………

DIODE AND CONTINUITY TEST

……………

NCV MEASUREMENT

…………………

TEMPERATURE MEASUREMENT

………………………

MAINTENANCE

…………………………

1

 

TROUBLE SHOOTING

…………………………

1

 

 

1.

 

SUMMARY 

This 3 3/4 Digit Highly Stable clamp meter uses two AAA (1.5V) 

batteries. It has a LCD with 18mm digit display, which makes the 

reading clearer and the operation more convenient. It can test DCV, 

ACV, ACA, resistance, NCV, temperature, diode and continuity test. 

This meter also equips data hold function with unit symbol display, 

can work in both auto and manual range, and provides auto power off, 

clamp light, backlight and warning functions. To assure high 

accuracy and resolution, it adopts an 8-bit microprocessor and a dual 

integral A/D convertor IC .It is an ideal tool for labs, factories 

radio-technology and household. 

2. SAFETY NOTICE 

The instrument is designed according to IEC1010-1(EN61010-1), 

Pollution 2, CAT III 600V and UL3111-1 standard (safety standard 

issued by International Electro technical Committee). Please read the 

followings carefully before any operation. 

2.1 Introduction for safety symbols: 

  : Be careful! Operator must refer to manual. 

  : Low battery indication. 

:  Warning! Existing High Voltage. 

  : Dual Insulation. 

2.2 Notice: 

2.2.1 Please read the manual carefully and strictly obey the 

instructions to avoid any human health and meter damage. 

2.2.2 To avoid electric shock and damage to the meter, please 

disconnect the input signal and remove away the test leads before 

opening the cover. Avoid the water leakage into the cover. 

2.2.3 DO NOT do any test if the cover hasn’t been completely 

installed or screws not tightened up.

 

2.2.4 DO NOT input the value higher than the limit at every range. 

2.2.5 DO NOT input any voltage at Resistance range. 

2.2.6 Switch OFF the meter after used. 

2.2.7 Please take out the batteries for long-time storage to avoid 

leakage damage. 

2.2.8 Be careful when the testing over DCV 60V and ACV 30V.. 

2.2.9 To avoid electric shock, please be seriously careful when 

nipping the bus bar or something insulated. 

3. FEATURES 

3.1 GENERAL FEATURES 

3.1.1 Display: LCD. 

3.1.2 Max. Display: 4000 digits (3 3/4) and auto polarity display. 

3.1.3

 

Clamp Max.open: 28mm 

3.1.4 Over-range display: “OL” displayed. 
3.1.5 Hold: DATA HOLD. 
3.1.6 Relative measurement. 
3.1.7 Sampling rate: approx.3 times/sec. 
3.1.8 Low battery indicator: “ ”displayed. 
3.1.9 Continuity test: Approx. less than 

50

±

10

)Ω

buzzer sounds. 

3.1.10 Auto or manual range. 
3.1.11 Auto power off. 
3.1.12 Power consumption: about 3mA. 
3.1.13 Power: 2 × 1.5V batteries (AAA 7#battery).

 

3.1.14 Working environment: (0

40)

, relative humidity: <70%.   

3.1.15 Dimension: 123mm×270mm×35mm (width×length×height). 
3.1.16 Weight: approx. 280g (including batteries).              
3.1.17 Accessories: user manual, test leads, temperature sensor banana 
probe TP01, 2pcs 1.5V batteries, black pouch, gift box   

3.2 TECHNICAL FEATURES 

3.2.1 Accuracy

:

 

± (a% × reading data + digits). To assure accuracy, the

 

environment temperature should be (23±5) 

, relative humidity be 

<70%.

 

One year accuracy guarantee since production date. 

3.2.2 Temperature Coefficient: 0.1* Specified Accuracy/1

 (<18

 

or >28

3.2.3 DC voltage (DCV) 

Range Accuracy 

Resolution 

400mV 

±(1.0% 5

 

0.1mV 

4V 

±(0.5% 5

 

1mV 

40V 10mV 

400V 100mV 

Содержание CM-2007

Страница 1: ... To avoid electric shock and damage to the meter please disconnect the input signal and remove away the test leads before opening the cover Avoid the water leakage into the cover 2 2 3 DO NOT do any test if the cover hasn t been completely installed or screws not tightened up 2 2 4 DO NOT input the value higher than the limit at every range 2 2 5 DO NOT input any voltage at Resistance range 2 2 6 ...

Страница 2: ... 100pF 4uF 1nF 40uF 10nF 200uF 5 0 reading 10 100nF Overload protection 250V RMS NOTE DO NOT input any voltage value at this range 3 2 8 Frequency test Range Accuracy Resolution 100Hz 0 5 reading 5 0 1Hz 1kHz 0 1Hz 10kHz 1Hz 100kHz 10Hz 1MHz 100Hz 10MHz 1kHz Input sensitivity 0 7V Overload protection 250V RMS 3 2 9 Temperature test Range Accuracy Resolution 40 750 400 1 0 5 400 1 5 15 1 Sensor K t...

Страница 3: ...easurement inputs positive terminal red test lead COM input terminal Measurement inputs negative terminal black test lead Carrying belt 4 2 ACA MEASUREMENT 1 Turn the rotary switch to range 2 Open the clamp jaw and grip one wire and get the reading directly To get the most precise reading should user put the wire in the middle of the close jaw refer to the picture 3 Note 1 Firstly users should sel...

Страница 4: ... the red test leads is for positive pole LCD displays capacitance value Note 1 Don t input voltage or current at Capacitance range 2 In order to assure the accuracy please press REL to clear the reading before testing 3 There is only the auto range mode under the capacitance range 4 The capacitor must be completely discharged before testing 5 The reading of 200uF range will take more than 15 secon...

Страница 5: ...OLD key signal appears Replace battery Big error Value Replace battery The specifications are subject to changes without prior notice The content of this manual is regarded as correct If users find out any mistakes or omissions please kindly contact the manufacturer The manufacturer will not be responsible for accidents and damage caused by improper operations The functions described in this User ...

Отзывы: