Fig. 28: Setting the adjustment mode of image temperature 

 
2.  Use the keys 

 and 

 to set the desired value of the temperature associated to the 

minimum level. Press and hold the keys for a quick setting of the value. 

3.  Press the key   to go to the upper level of the color palette (see Fig. 28 – Right side). 
4.  Use the keys 

 and 

 to set the desired value of the temperature associated to the 

maximum level. Press and hold the keys for a quick setting of the value. 

5.  Press  the  “Ok”  key  to  confirm.  The  values  of  the  set  levels  are  maintained  by  the 

instrument until a new modification is performed. 

6.  Press the right key 

 to go back to Auto mode. 

 

 

CAUTION 

 

 

Automatic (Auto)

 mode 

 the minimum and maximum temperature levels 

of the framed object on the display and associated with the colour palette 

are  automatically  defined  by  the  instrument  and  dynamically  vary  when 

moving it. This (default) option, which can be used in most cases, allows for 

an optimum display of the IR image in a condition of temperatures equally 

distributed within it. 

 

Manual

  mode 

  the  minimum  and  maximum  temperature  level  of  the 

object  framed  on  the  display  are  manually  set  by  the  user.  This  mode, 

particularly  useful  to  clearly  identify  only  some  areas  of  the  image,  is 

recommended in case of advanced thermographic operations. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание THT45

Страница 1: ...Copyright HT ITALIA 2020 Version EN 2 03 24 03 2020 ENGLISH User manual...

Страница 2: ...u 23 5 2 6 Range Menu 24 5 2 7 Image adjustment 24 5 3 Saving the image on the display 26 5 4 Recording a video on the display 26 5 5 Recalling and deleting displayed images and videos 27 5 5 1 Playba...

Страница 3: ...s They must be used only if in good conditions and replaced with identical models when necessary Check that the battery is correctly inserted Check that the LCD display gives indications consistent wi...

Страница 4: ...g function for surface temperature rapid measurement Storage of JPG images on external micro SD card IR sensor resolution 80x80pxl THT45 THT45W 160x120pxl THT46 USB port for PC connection and image tr...

Страница 5: ...kaging contains all components indicated in 8 5 In case of discrepancy please contact the Dealer In case the instrument should be replaced please carefully follow the instructions given in 10 3 2 INST...

Страница 6: ...rument s front and backside CAPTION 1 LCD display 2 Function keys 3 Holes for non slip strap 4 Lens protection cap 5 In built visual photo camera 6 Laser pointer 7 Built in illuminator 8 Lens associat...

Страница 7: ...T 14 Instrument s inputs and outputs location Fig 3 Description of the instrument s inputs and outputs CAPTION 15 Battery charge indicator LED 16 Input for connecting AC adapter battery charger and mi...

Страница 8: ...THT45 THT45W THT46 EN 7 Fig 4 Description of the instrument s battery compartment CAPTION 1 Inside of the battery compartment 2 Battery insertion section...

Страница 9: ...tem parameters 4 2 3 Key Pressing and hold the key allows activating deactivating the internal illuminator see Fig 1 Part 6 The same key is also used for the selection of system parameters 4 2 4 Key P...

Страница 10: ...percentage x1 x32 Battery charge level indication see 8 2 Indication of active WiFi connection only THT45W 17 28 Indication of the system s current time Level Indication of temperature levels of the I...

Страница 11: ...to the original image 5 1 3 Adjusting the distance of the object in Fusion screens In Fusion display mode see 5 2 4 due to the different position of the lens and of the built in photo camera when the...

Страница 12: ...measuring max 3 cursors Emiss menu defines the setting of the emissivity of the object the reflected temperature and the parameter of Screening function Image menu defines the display modes of the ima...

Страница 13: ...anguage setting 2 Use the or keys to select the desired language among the ones available 3 Press the key Select to confirm or Close to exit without saving Section Temp Unit In this section it is poss...

Страница 14: ...the instrument 2 Press the key Select to restore the default conditions see Table 1 or Close to cancel the operation Parameter Default setting Cursor in the middle of the display On Max temperature m...

Страница 15: ...desired values of date and time 4 Press the key Ok to confirm or Cancel to exit without saving Information section This section contains general information about the instrument 1 Select the item Inf...

Страница 16: ...ance among the options 0 5m 1m 1 5m or 2m 3 Press the key Select to confirm or Close to exit without saving Auto power off section In this section it is possible to enable disable and adjust the auto...

Страница 17: ...nes 3 Press the key Select to confirm or Close to exit without saving WiFi section THT45W In this section it is possible to enable disable the WiFi feature for the connection of the instrument to mobi...

Страница 18: ...the item Measurement with the keys or and press the key The screen Fig 17 Right side is shown on the display Fig 17 Setting of measuring cursors 2 Use the keys or and press and hold the key Select or...

Страница 19: ...tely 0 95 Material Emissivity Water 0 96 Stainless steel 0 14 Aluminium foil 0 09 Asphalt 0 96 Cement 0 97 Cast iron 0 81 Rubber 0 95 Wood 0 85 Bricks 0 75 Tape 0 96 Brass foil 0 06 Human skin 0 98 PV...

Страница 20: ...e item Custom and confirm your custom setting of the emissivity value with the Select key Use the keys or to set the value in the range 0 01 1 00 4 Press the Close key to confirm your setting and to g...

Страница 21: ...ress the key The screen Fig 20 Central part is shown on the display Fig 20 Setting temperature compensation on the instrument 2 Use the keys or to select the item Alarm and press the key Select The sc...

Страница 22: ...previous screen 5 2 4 Image menu In this section it is possible to select the display mode of IR and visual images 1 Select the item Image using the keys or and press the key The screen Fig 22 Right...

Страница 23: ...the optimum level of mixing percentage between IR and visible part of the image This allows the saving of better quality pictures even in low contrast conditions object temperature similar to the same...

Страница 24: ...it is possible to select the color palette which can be associated to the IR image 1 Select the item Palette using the keys or and press the key The screen Fig 26 Right side is shown on the display Fi...

Страница 25: ...the options 20 C 150 C 0 C 350 C or Screening see 5 5 3 3 Press the Select key or the key to confirm the operation and go back to the previous screen of the Close key to exit without any modification...

Страница 26: ...y the instrument until a new modification is performed 6 Press the right key to go back to Auto mode CAUTION Automatic Auto mode the minimum and maximum temperature levels of the framed object on the...

Страница 27: ...Saving the image on the display 5 Press the Cancel key to exit without saving 5 4 RECORDING A VIDEO ON THE DISPLAY 1 Insert the micro SD card into the relevant slot of the instrument see Fig 4 The ic...

Страница 28: ...s the key Browse to access the gallery of saved images videos see Fig 31 Left side 4 Press the key Open to recall the selected image video on the display 5 Press the Option key The following screen ap...

Страница 29: ...rt the jack of the headphones into the instrument see Fig 2 Part 17 3 Adjust the level of sound volume see 5 2 1 4 Press the T Trigger key to activate video playback A cursor and progress bar are show...

Страница 30: ...ument is switched on and continues during the thermal cameras normal operation during which the image freezes for a few seconds in order to eliminate offset errors The noise produced by the commutatio...

Страница 31: ...strictly necessary emissivity value may be set to 1 see 5 2 3 it is not necessary to consider the objects surface its distance and the field of view However if accurate measures are required e g the...

Страница 32: ...m temperature threshold by using the or keys see 5 2 3 6 Activate the visualization of the S fixed central spot cursor on the display inside the Measure menu see 5 2 2 7 Select the desired color palet...

Страница 33: ...Fig 3 Part 16 and to the PC The following screen see Fig 38 Left side is shown on the display Fig 38 Transferring images videos onto the PC 4 Use the keys or to select the option PC Transfer and press...

Страница 34: ...image on the instrument s display in real time 4 Disconnect the USB cable to go back to the instrument s main screen 5 8 HDMI VIDEO OUTPUT The video output available in the instrument see Fig 2 Part...

Страница 35: ...real time of color palettes Saving snapshots within the mobile device Download images from instrument with USB OTG cable connection Creation of reports in PDF format Sharing images snapshots reports v...

Страница 36: ...e image Visualization of Fusion image see 5 2 4 Visualization of Auto Fusion image AUF see 5 2 4 1 Selection of Iron palette Selection of Rainbow palette Selection of Grey scale palette Selection of R...

Страница 37: ...ard USB mode 2 Copy of IR images from PC or micro SD card Fig 42 Visualization of images gallery Analysis and sharing IR images 1 Touch the menu icon and select the Library option in order to open the...

Страница 38: ...the previous menu Function Description Allows to view the properties of the open image name size instrument model Allows to delete the open image Allows to define the name of the report related to the...

Страница 39: ...THT45 THT45W THT46 EN 38 Funcion Description Allows you to select the type of image report sharing program saved on the mobile device e mail social networks cloud etc Fig 46 Shared of images report...

Страница 40: ...on CD ROM into the reader of the PC 2 Launch the file THTLink exe found inside the CD ROM and follow the guided installation procedure 7 3 MAIN CHARACTERISTICS OF THE THTLINK SOFTWARE With launched pr...

Страница 41: ...nyway in a range between 0 C and 50 C 32 F and 122 F When using the instrument for the first time recharge the battery for at least 6 hours 1 Connect the battery charger provided with the instrument t...

Страница 42: ...battery 3 7V 2000mAh AC DC 100 240V 5V adapter universal plugs Micro SD card 8GB USB cable USB OTG cable HDMI video cable Set of headphones for intercom Non slip strap CD ROM with Windows software TH...

Страница 43: ...readings C F K Available colour palettes 4 Iron Rainbow Grey Grey Inverse Laser pointer class 2 according to IEC 60825 1 Built in illuminator white LED light Electronic zoom x1 x32 Emissivity correcti...

Страница 44: ...0 C 40 F 158 F Allowable relative humidity 10 90 RH Encapsulation IP50 according to IEC529 Fall test 2m Shock 25G in compliance with IEC60068 2 29 Vibrations 2G in compliance with IEC60068 2 6 This in...

Страница 45: ...as a consequence of improper packaging Repairs which may become necessary as a consequence of interventions performed by unauthorized personnel Modifications to the instrument performed without the ma...