HT60
EN - 7
4.2. DESCRIPTION OF FUNCTION KEYS
4.2.1. HOLD
key
Pressing the
HOLD
key freezes the value of the measured quantity on the display. After
pressing this key, the message
“
HOLD
”
appears on the display. Press the
HOLD
key again
to exit the function.
Press and hold the same key for longer than one second to activate and deactivate the
display
’
s backlight. This function is active in any position of the rotary switch.
4.2.2. Hz%
key
Press the
Hz%
key to select frequency measurement and duty cycle test in positions
V
Hz%
and
Hz%
of the rotary switch. The frequency range is different in the two
positions.
4.2.3. REL
key
Press the
REL
key to activate relative measurement. The instrument zeroes the display
and saves the displayed value as a reference value which subsequent measurements will
be referred to. The symbol
“
REL
”
appears on the display. This function is not active for the
following measurements: Hz, Duty Cycle, Continuity Test, Diode test and Temperature.
Press the key again to exit the function.
4.2.4. MODE
key
Pressing the
MODE
key allows selecting a double function on the rotary switch. In
particular, it is active in position
to select diode test, continuity test, capacity
measurement, resistance measurement and in positions
V
Hz%
and
LoZV
for AC or
DC voltage selection.
4.2.5. LoZ
feature
This mode permits to perform the AC/DC voltage measurement with a low input
impedance in way to avoid the wrong readings due to stray voltage in capacitive coupled.
CAUTION
Inserting the instrument between phase and ground conductors, the RCDs
protection devices can be tripping out during the test. For phase-PE voltage
measurement after a RCD device preliminarily connect the test leads
between phase and neutral cables at least for 5s, then perform the phase-
PE measurement to avoid unexpected trips-out.
4.2.6. Auto-Power-Off
function
In order to preserve internal batteries, the instrument switches off automatically
approximately 30 minutes after it was last used. Turn the rotary switch to OFF before
switching on the instrument again by turning the switch to any other position.
Содержание HT60
Страница 3: ... Copyright HT ITALIA 2017 Versione IT 1 02 07 04 2017 ITALIANO Manuale d uso ...
Страница 24: ......
Страница 25: ... Copyright HT ITALIA 2017 Version EN 1 02 07 04 2017 ENGLISH User manual ...
Страница 46: ......
Страница 47: ... Copyright HT ITALIA 2017 Versión ES 1 02 07 04 2017 ESPAÑOL Manual de instrucciones ...
Страница 68: ......
Страница 69: ... Copyright HT ITALIA 2017 Version DE 1 02 07 04 2017 DEUTSCH Bedienungsanleitung ...
Страница 90: ......
Страница 91: ... Copyright HT ITALIA 2017 Version FR 1 02 07 04 2017 FRANÇAIS Manuel d utilisation ...