5.2.
SPEED MEASURE WITH CONTACT
1. Insert the proper rubber head on the mechanical adapter.
2. Attach the mechanical adaptor to the unit
and fasten the screw
(see Fig. 3):
Fig. 3: attach of mechanical adaptor
3. Press
ON/OFF
key to turn ON the meter.
4. Press
UNIT
key to select RPM / unit.
5. Press against the shaft of the object to be measured. Do not press against the shaft too
hard to avoid hazardus situation for operator.
6. Press
START
key once to enable measure.
symbol is shown at display.
7. Press
START
key again to stop measure. "
H
” symbol is shown at display.
8. The result of test and his duration is shown at display.
CAUTION
•