4.3. 

FUNCTION KEY DESCRIPTION 

 

4.3.1. ON/OFF key 

By pushing 

ON/OFF

 key permits to turn on the instrument. For an instant all display 

segments light up, then the firmware release appears on the top right side. When “

on

” is 

displayed the instrument is ready to start (see Fig. 3) 
 

 

Fig. 3: Initial screen of instrument 

 

By pushing long (>1s) 

ON/OFF

 key to switch off the instrument 

 

4.3.2.  UTP and STP keys 

By pressing 

UTP

 or 

STP

 keys  it’s possible to select the type of cable to be tested, with the 

following difference: STP performs also tests on the shield (continuity and proper 
connections) while UTP doesn’t. Consequently STP must be pressed for all shielded 
cables such as: FTP (Foiled Twisted Pair cable), STP (Shielded Twisted Pair cable), SSTP 
(Shielded/Shielded Twisted Pair cable) and SFTP (Shielded/Foiled Twisted Pair cable) 
 

 

CAUTION 

 

 

 

By default the selected cable is 

STP

. Any time the instrument is turned off 

and on such type of cable is automatically selected 

 

4.3.3. GO 

key 

By pushing 

GO

 key to activate the wire mapping test of LAN cable connected between the 

instrument’s input and the remote unit used (see § 5.1). 
 

4.3.4. 

 and 

/  

keys 

By pushing 

 or 

/

 keys for the selection  of the errors detected by the instrument at 

the end of wire mapping test on cable (see § 5.2). 
By pushing long (>2s) of 

UNIT/

 key permits to activate/disable the backlight 

 

4.3.5.  Auto Power OFF feature 

The instrument is provided with Auto Power OFF (APO) feature which automatically 
permits to switch it off after approx..4 minutes of idleness in order to preserve the internal 
battery. 
 
 
 
 
 

Содержание QUICKLAN 6055

Страница 1: ...Copyright HT ITALIA 2016 Release EN 3 00 19 09 2017 ENGLISH User manual...

Страница 2: ...and STP keys 5 4 3 3 GO key 5 4 3 4 and keys 5 4 3 5 Auto Power OFF feature 5 5 OPERATING INSTRUCTIONS 6 5 1 Cabling test verify 6 5 2 Cabling errors 7 5 3 Split pairs explanation note 9 6 MAINTENANCE...

Страница 3: ...ticing applicable safety precautions must use this product Do not perform any measurement under conditions beyond the limits specified in this manual CAUTION Connect the tester only to inactive cables...

Страница 4: ...o check it rapidly eventual damages may have occurred during transport Make sure that all standard accessories mentioned in 7 4 1 are included Should you have to return back the instrument for any rea...

Страница 5: ...1 2 Fig 1 Instrument description 4 2 DISPLAY DESCRIPTION CAPTION 1 Type of selected cable 2 Low battery indication 3 Final test outcome 4 Running test indication 5 Fault test indication 6 Caution and...

Страница 6: ...ch as FTP Foiled Twisted Pair cable STP Shielded Twisted Pair cable SSTP Shielded Shielded Twisted Pair cable and SFTP Shielded Foiled Twisted Pair cable CAUTION By default the selected cable is STP A...

Страница 7: ...cable under test to the meter and to the remote unit by using if necessary through supplied patch cables see Fig 4 Fig 4 Instrument connection 4 Press GO key The message MEASURING is shown and the ins...

Страница 8: ...s the presence of a voltage 0 2V on the RJ45 input it shows the message in the screen on the right and do not perform the test Eliminate the cause of the presence of voltage e g coupling due to the pr...

Страница 9: ...een each other TRANSPOSED CROSSED PAIRS Two pairs are crossed MISWIRE Generic cabling error such as for example two conductors belonging to different pairs are exchanged SPLIT PAIRS The pin to pin cor...

Страница 10: ...ge of two conductors belonging to different pairs The pin to pin correspondence seems intact but physically the conductors of two couples are split Such interaction hardly affects or even makes imposs...

Страница 11: ...tery CAUTION Only skilled technicians can open the instrument and replace batteries Before removing batteries disconnect the test leads from any energized circuits to avoid electrical shocks 1 Switch...

Страница 12: ...uto Power OFF after 4 minutes of idleness not disabled 7 3 ENVIRONMENT 7 3 1 Environmental conditions Working temperature 0 C 40 C 32 F 104 F Relative humidity 80 RH Storage temperature 0 C 40 C 32 F...

Страница 13: ...not skilled or unauthorized personnel Instruments for whatever reason modified by the customer himself without explicit authorization of our Technical Dept The contents of this manual may not be repr...

Отзывы: