4.  The jump starter will fully charge in 7-8 hours. When the unit is fully 

charged, the display will show “100%”.

5.  When the battery is fully charged, disconnect your charger from the 

outlet, and then remove the charging cable from the charger and the 

unit. Slide the ON/OFF switch to the OFF position, if you are not using 

the unit immediately.

7.  OPERATING INSTRUCTIONS

7.1  JUMP STARTING A VEHICLE ENGINE

NOTE: Use model number SA866 jump cable.

IMPORTANT: Do not use the jump starter while charging its internal battery.

IMPORTANT: Using the jump starter without a battery installed in the 

vehicle will damage the vehicle’s electrical system.

NOTE: The internal battery must have a charge if at least 40% to 

jump start a vehicle.

1.  Turn the ignition OFF.

2.  Plug the battery clamp cable into the jump starter’s output socket.

3.  Lay the DC cables away from any fan blades, belts, pulleys and other 

moving parts. Make sure all of the vehicle’s electrical devices are turned off.

4.  For a negative-grounded vehicle, connect the POSITIVE (RED) clamp 

from the jump starter to the POSITIVE (POS, P, +) ungrounded post 

of the battery. Connect the NEGATIVE (BLACK) clamp to the vehicle 

chassis or engine block away from the battery. Do not connect the 

clamp to the carburetor, fuel lines or sheet-metal body parts. Connect 

to a heavy gauge metal part of the frame or engine block.

5.  For a positive-grounded vehicle, connect the NEGATIVE (BLACK) 

clamp from the jump starter to the NEGATIVE (NEG, N, -) ungrounded 

post of the battery. Connect the POSITIVE (RED) clamp to the vehicle 

chassis or engine block away from the battery. Do not connect the 

clamp to the carburetor, fuel lines or sheet-metal body parts. Connect to 

a heavy gauge metal part of the frame or engine block.

6.  Slide the ON/OFF switch to the ON position. The green LED on the 

smart cable should light. 

NOTE: If the vehicle battery is extremely discharged, the initial current 

draw from the jump starter may activate short circuit protection in the 

smart cable. When the condition is corrected, the smart cable will 

automatically reset.

7.  After a proper connection has been made, crank the engine. If the engine 

does not start within 5-8 seconds, stop cranking and wait at least 1 minute 

before attempting to start the vehicle again.  

NOTE: If the car does not crank a second time, check the smart cable 

to see if the green LED is lit. If an LED is flashing, refer to section 10,  

Troubleshooting. When the condition is corrected, the smart cable will 

automatically reset.

NOTE: Cold weather may affect the performance of the jump starter’s 

lithium battery. If you hear only a click and the engine does not turn 

over, try the following:

Содержание HSV-SPZ-189901

Страница 1: ... THIS OWNER S MANUAL AND READ BEFORE EACH USE This manual will explain how to use the unit safely and effectively Please read and follow these instructions and precautions carefully Jump Starter MODEL HSV SPZ 189901 User Manual ...

Страница 2: ...Do not expose the unit to rain or snow 1 5 Use only recommended attachments SA866 jump cable Use of an attachment not recommended or sold by the jump starter manufacturer for the HSV SPZ 189901 may result in a risk of fire electric shock or injury to persons or damage to property 1 6 To reduce the risk of damage to the electric plug or cord pull by the adaptor rather than the cord when disconnecti...

Страница 3: ...ng soda nearby for use in case battery acid contacts your eyes skin or clothing 2 8 Wear complete eye and body protection including safety goggles and protective clothing Avoid touching your eyes while working near the battery 2 9 If battery acid contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye immediately flood the eye with cold running water fo...

Страница 4: ...tal part of the battery clips or cut the insulation of the cables 4 3 Stay clear of fan blades belts pulleys and other parts that can cause injury 4 4 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 4 5 Determine which post of the battery is grounded connected to the chassis If the negative post is grounded to the c...

Страница 5: ...e of charge Afully charged internal battery will read 100 Charge the internal battery if the display shows it is under 85 2 To reduce the risk of electric shock unplug the unit s charging cable from a USB or wall charger before attempting any maintenance or cleaning Simply turning off the controls will not reduce this risk 3 When charging the internal battery work in a well ventilated area and do ...

Страница 6: ... clamp to the carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block 5 For a positive grounded vehicle connect the NEGATIVE BLACK clamp from the jump starter to the NEGATIVE NEG N ungrounded post of the battery Connect the POSITIVE RED clamp to the vehicle chassis or engine block away from the battery Do not connect the clamp to the carbure...

Страница 7: ...vice manufacturer for proper charging power specifications Connect a mobile device cable to the appropriate USB port 2 Slide the ON OFF switch to the ON position Charging should begin automatically The display will show which port is in use 3 Charging time will vary based on the mobile device s battery size and the charging port used NOTE Most devices will charge with any of the USB ports but may ...

Страница 8: ... set to the ON position The thermometer symbol is flashing The unit is too hot or cold The thermometer symbol will disappear when the condition is removed The jump starter will not recharge Make sure the power source is live The jump starter turns on but won t jump start my vehicle Check connections Verify the charge level of the jump starter is at least 40 Do not attempt to jump start your vehicl...

Страница 9: ...rnating Red and Green flashing LEDs no beep Reverse charging protection Solid Red LED Green LED off rapid beeping Short circuit protection Solid Red and Green LEDs beeps once per second Temperature protection NOTE When the condition is corrected the smart cable will automatically reset 11 SPECIFICATIONS Internal battery type Lithium ion polymer Capacity 55 5 Wh USB output Standard 5V DC 2 4A USB i...

Страница 10: ...n 2 months after discovery of the non conformity Resellers Professional End User Warranty The Manufacturer provides a limited warranty for hidden defects or non conformities This warranty is subject to the following conditions a The Manufacturer only warrants hidden defects in material or workmanship present in their root cause at the moment of the first sale by the Manufacturer b Manufacturer s o...

Страница 11: ...the above warranties Non authorized resellers may only sell the product under the condition that they assume all warranty obligations with the total exclusion of any warranty provided by the Manufacturer Manufacturer does not provide any warranty for any accessories used with the Product that are not manufactured by Schumacher Electric Corporation This warranty does not exclude or diminish any cla...

Страница 12: ......

Отзывы: