7.Technical Specifications   

 

 

 

  

•  6.1 kg Weight   

•  1,100 Watt 220 V AC 50-60 Hz Electric motor  

•  Adjustable Rotation Speed   

•  Assurance of homogeneous fogging distribution through 360° rotation drum   

•  Dry and Wet mist projection by Venturi effect up to 15 meters radius from the appliance   

•  Speed of mist flow rate 80 m/s  

•  Droplet size : 7-20  micron  

•  Interchangable cardridge 1 ltr.   

•  0.5 – 1.2 ml per cubic metre according to adjustable droplet size.  

•   Programmable volume from 0 – 1,000 m

3

    

  
  
  

 

8. Troubleshooting   

 

 

  

 

  
 

Problem  

 

Reason  

 

Solution  

 

  
Machine is not working    

No Electricity 

Check the supply.  

Power Button OFF   

Turn to ON position  

Unit is faulty   

Contact the Supplier 

Rotation is not working   
  

Button OFF   

 

Engine is faulty  

Take the ON position  
 
Contact the Supplier 

  
  
Not spraying   

  

m

 3

/ml adjuster is OFF   

Adjust   

Suction pipe is choked   

Flush the pipe    

No liquid in the cartridge    

Fill the cartridge    

Application stopped early   

Adjust m

 3 

  

Air filter is dirty  

Contact the Supplier 

  
  
  
  
  
  
  

Содержание BioSpray

Страница 1: ...ls are no longer required they should be disposed of properly in accordance with applicable local regulations Corrugated board packaging materials may be recycled or reused At the end of the equipment s service life please make sure that you dispose of it in accordance with the official directives and regulations that apply in your area The manufacturer reserves the right to change the design and ...

Страница 2: ...intenance and Repair 2 2 Replacement Parts 2 3 Guarantee 3 Important Components 4 Safety regulations 4 1 Correct use Application 4 2 General safety instructions 4 3 Protection of Environment 4 4 Operating Hints 5 Maintenance and care 6 STARTING THE FOGGER 7 Technical Specifications 8 TROUBLESHOOTING ...

Страница 3: ...will assume the costs for defect remediation by replacing the defective parts in the case of material or manufacturing defects that occur within the guarantee period after the date of purchase Please note that specific guarantee conditions apply in some countries Warranty terms specifically exclude damages due to the following Non compliance with the operating instructions Neglecting required main...

Страница 4: ...User Manual Page 4 of 10 3 Important Components Area m3 adjuster m3 ml adjuster Suction pipe ...

Страница 5: ...User Manual Page 5 of 10 ...

Страница 6: ... instructions Please read the operating instructions carefully before placing in service and keep them in a safe place First time users should take particular care The operator of the unit is responsible for the health and safety of others within the operating area Only operate the unit when in good physical condition Fatigue and illness lead to carelessness and accidents Proceed with caution at a...

Страница 7: ...e Wear suitable PPE 4 4 Operating Hints No other persons or animals should be present within a circle of 100 meters while the machine is running Objects carried by the air stream can deflect and cause injury or damage Never operate the unit whilst it is in any way unstable Pay particular attention to the safety aspects of any chemical or solution to be used in the fogger unit If in doubt contact t...

Страница 8: ...e by turning counter clockwise 2 Fill the cartridge with the liquid based disinfectant and restore it to the screw in fitting on the fogging unit 3 Plug the machine into a grounded power outlet 4 Calculate the volume of the target zone and set the appropriate volume on the dial ...

Страница 9: ...on and discharge the area The unit will start automatically 30 seconds 6 The machine will stop automatically after disinfection is complete based on the volume setting 7 Ensure the disinfected zone is kept isolated for the period of time required to dissipate residual disinfectant Contact your chemicals provider if in doubt ...

Страница 10: ...ge 1 ltr 0 5 1 2 ml per cubic metre according to adjustable droplet size Programmable volume from 0 1 000 m3 8 Troubleshooting Problem Reason Solution Machine is not working No Electricity Check the supply Power Button OFF Turn to ON position Unit is faulty Contact the Supplier Rotation is not working Button OFF Engine is faulty Take the ON position Contact the Supplier Not spraying m 3 ml adjuste...

Отзывы: