background image

McElwaine Technical Services Limited 

 

Page 

1

 of 

10

 

 

BioSpray User Manual 

 

 

 

Prior to operating the unit, please read the 

owner’s manual carefully, and most 
importantly, observe all safety rules. Follow 
the maintenance guidelines to ensure the 
long service life of your equipment. We will be 
happy to assist you with any questions.  

 
Tel:  

+44 28 6772 4455 

Email:  [email protected]

 

 

 

EC  declaration  of  conformity 

The  EC 

declaration  of  conformity 

on  a  separate 

document 

forms  part  of  these  operating 

instructions.    Please  contact  us  if  this  is 
required. 

  

Packaging and Disposal 

 

 

 

Please keep the original packaging in order to 
protect  the  equipment  against  transport 
damage in the event that you ever need to ship 
it or transport it.  
 
If  the  packaging  materials  are  no  longer 
required, they should be disposed of properly in 
accordance with applicable local regulations.  
 
Corrugated board packaging materials may be 
recycled or reused.  
 
At  the  end  of  the  equipment’s  service  life, 
please  make  sure  that  you  dispose  of  it  in 
accordance  with  the  official  directives  and 
regulations that apply in your area. 
  
  
  
  

  

  
The manufacturer reserves the right to change 

the  design  and  configuration  of  any  product 
without  prior  notice.  For  that  reason,  claims 
cannot be accepted with reference to text and 
illustrations in this manual. 

  

  

  

  

  

 

 

  

 

 

  

Symbols

 

 

 

The following symbols are used in this manual 

and on the product:  

  
Always handle this power tool with  
particular care  
  

  

Thoroughly read these operating 
instructions before undertaking any 
maintenance, installation and cleaning 
steps  

  

Wear protective gloves when handling  

   and working with the equipment  
  
A breathing mask should be worn when 
using chemicals. 
  
  
Pesticides can be flammable.  
  

  

  

  

Labelling

 

 

  

 

  
  

 

   
  
  
  

  

  

Содержание BioSpray

Страница 1: ...ls are no longer required they should be disposed of properly in accordance with applicable local regulations Corrugated board packaging materials may be recycled or reused At the end of the equipment s service life please make sure that you dispose of it in accordance with the official directives and regulations that apply in your area The manufacturer reserves the right to change the design and ...

Страница 2: ...intenance and Repair 2 2 Replacement Parts 2 3 Guarantee 3 Important Components 4 Safety regulations 4 1 Correct use Application 4 2 General safety instructions 4 3 Protection of Environment 4 4 Operating Hints 5 Maintenance and care 6 STARTING THE FOGGER 7 Technical Specifications 8 TROUBLESHOOTING ...

Страница 3: ...will assume the costs for defect remediation by replacing the defective parts in the case of material or manufacturing defects that occur within the guarantee period after the date of purchase Please note that specific guarantee conditions apply in some countries Warranty terms specifically exclude damages due to the following Non compliance with the operating instructions Neglecting required main...

Страница 4: ...User Manual Page 4 of 10 3 Important Components Area m3 adjuster m3 ml adjuster Suction pipe ...

Страница 5: ...User Manual Page 5 of 10 ...

Страница 6: ... instructions Please read the operating instructions carefully before placing in service and keep them in a safe place First time users should take particular care The operator of the unit is responsible for the health and safety of others within the operating area Only operate the unit when in good physical condition Fatigue and illness lead to carelessness and accidents Proceed with caution at a...

Страница 7: ...e Wear suitable PPE 4 4 Operating Hints No other persons or animals should be present within a circle of 100 meters while the machine is running Objects carried by the air stream can deflect and cause injury or damage Never operate the unit whilst it is in any way unstable Pay particular attention to the safety aspects of any chemical or solution to be used in the fogger unit If in doubt contact t...

Страница 8: ...e by turning counter clockwise 2 Fill the cartridge with the liquid based disinfectant and restore it to the screw in fitting on the fogging unit 3 Plug the machine into a grounded power outlet 4 Calculate the volume of the target zone and set the appropriate volume on the dial ...

Страница 9: ...on and discharge the area The unit will start automatically 30 seconds 6 The machine will stop automatically after disinfection is complete based on the volume setting 7 Ensure the disinfected zone is kept isolated for the period of time required to dissipate residual disinfectant Contact your chemicals provider if in doubt ...

Страница 10: ...ge 1 ltr 0 5 1 2 ml per cubic metre according to adjustable droplet size Programmable volume from 0 1 000 m3 8 Troubleshooting Problem Reason Solution Machine is not working No Electricity Check the supply Power Button OFF Turn to ON position Unit is faulty Contact the Supplier Rotation is not working Button OFF Engine is faulty Take the ON position Contact the Supplier Not spraying m 3 ml adjuste...

Отзывы: