QUICK START
WHAT YOU NEED
HOW TO OPERATE
Tube catcher
Use KING SIZE tubes only.
REMOVE any damaged, missshaped
or ‘oval’ tubes from the box.
3
Back Box Carriage
Position and fix the back box carriage
to preset screw holes.
1
Load tube magazine
Turn power on. Gently slide down
the tubes in the tube opening
until all tubes are loaded.
5
Suitable tobbaco
Tobacco size MUST be between1/4’ to 5/8”
(6mm to 16mm) and moisture MUST be
between 12% to 20% (ideally 14% or 15%).
4
Power cord
Insert the power cord into the machine
and plug into a power outlet.
2
Load tobbaco and start
Open the the tobacco hopper cover and fill
with approximately 0.5oz (15g) of tobacco
to make 10 cigarettes. Start a cycle.
6
HOW TO INSTALL
COMPLETE INSTRUCTIONS
Brush and run cycle
With the cleaning brushes provided,
clean the tobacco wheel feeder inside
the hopper.
2
Step 1. Power
Insert the power cord into the machine and plug into a
power outlet. When ready to start a cigarette making cycle
turn on the power switch on the back of the machine. The
front led display will turn red after a short delay.
Step 2. Tube catcher
Remove from the box any damaged, misshaped, or “oval”
tubes. Tilt the box to get the tubes perfectly aligned. Place
the
tube catcher
on the tube filters with the teeth of the tool
between tubes, directing the curve side of the
tube catcher
towards the right if you are right handed and left if you are
left handed. With a gentle push you will be able to catch10
tubes at once.
Step 3. Tube loading
Gently slide down the tubes in the
tube magazine
opening
until all tubes are loaded. Remove the
tube loader
by pulling
it smoothly away.
While using the
tube loader
tool is the most efficient way of
loading 10 tubes at once, you can also load the
tube loader
by hand. With 2 fingers, gently pick up a fresh, unwrinkled
cigarette tube at the filter. With the filter on the left, at
~30 degree angle, introduce the tube filter first in the
tube
loader
. Drop the tube. Ensure that the tube is being placed
correctly and gently in the
tube loader
. Do not force the
tube into the
tube loader
. Repeat the operation until you
have loaded all ten tubes. Note: Any damaged tubes will
disturb a proper cigarette making cycle. In both loading
ways, practice can be required.
Step 4. Tobacco loading
Use only tobaccos shown in the table printed on the hopper
cover: the moisture level of the tobacco MUST be between
12% to 20% (ideal 14% or 15%). The length of the tobacco
cut MUST be between 1/4’’ to 5/8’’ (6mm to 16mm). The
tobacco chopper and moisture meter supplied with the
Automatic HSPT Golden Rainbow 10 +
will help you adjust
your tobacco to the perfect usage standards. Open the
tobacco hopper cover and fill with ~0.5 oz (15 g) of tobacco
to make 10 cigarettes, then close the cover. Note: Use
of tobacco outside these specifications will jam and
possibly damage the machine.
Step 5. Starting the cycle and completion
Set-up the tobacco compaction needed on the level
control-setting knob (1 to 3).As you raise the level control
setting you will get a higher degree of compaction in the
tube. Through trial and error you can determine the best
compact setting based on yourown test and the size of
the filter of your favorite cigarette tube brand supplier.
Softly press the “Start/stop/return” button one time to
start the machine. This will produce 10 quality cigarettes
automatically in 2.5 minutes. The machine will automatically
stop at the end of the 10 cigarettes cycle.
If a problem occurs during cigarette cycle
production, press the “Pause /Continue”
button once and fix the issue by removing
deteriorated material like damaged
cigarette tubes or by removing excess
tobacco, then resume the cigarette making
cycle by pressing the “Pause/Continue”
button once again.
CAUTION:
Ideally, clean the machine after each cycle, never after more than three cycles. Turn off the power switch and
unplug the machine. Empty the machine of all supplies. Next open the tobacco hopper and drawer and the machine tuned
upside-down shaking it gently. This will removed potential tobacco residues stock in the machine. Then, using the brushes
provided, clean the machine as show on the above pictures. Clean the tobacco wheels feeder inside the hopper by pushing
tobacco inside the tobacco chamber (bottom of the tobacco hopper). Then, close the tobacco hopper cover. Turn the machine
back on and run the machine for one cycle with the tube magazine empty to clean the excess tobacco. Recycle the tobacco
from the cleaning process, which might still remain on the cleaning mat (supplied).
Never leave your machine not cleaned when your production is over for the day.
Empty hopper
Remove the drawer for excess tobacco.
1
HOW TO CLEAN