QUICK START

WHAT YOU NEED

HOW TO OPERATE

Tube catcher

Use KING SIZE tubes only.  

REMOVE any damaged, missshaped  

or ‘oval’ tubes from the box.

3

Back Box Carriage

Position and fix the back box carriage 

to preset screw holes.

1

Load tube magazine

Turn power on. Gently slide down  

the tubes in the tube opening  

until all tubes are loaded.

5

Suitable tobbaco

Tobacco size MUST be  between1/4’ to 5/8” 

(6mm to 16mm) and moisture MUST be 

between 12% to 20% (ideally 14% or 15%).

4

Power cord

Insert the power cord into the machine  

and plug into a power outlet.

2

Load tobbaco and start

Open the the tobacco hopper cover and fill 

with approximately 0.5oz (15g) of tobacco  

to make 10 cigarettes. Start a cycle.

6

HOW TO INSTALL

COMPLETE INSTRUCTIONS

Brush and run cycle

With the cleaning brushes provided, 

clean the tobacco wheel feeder inside 

the hopper.

2

Step 1. Power

Insert the power cord into the machine and plug into a 
power outlet. When ready to start a cigarette making cycle 
turn on the power switch on the back of the machine. The 
front led display will turn red after a short delay.

Step 2. Tube catcher

Remove from the box any damaged, misshaped, or “oval” 
tubes. Tilt the box to get the tubes perfectly aligned. Place 
the 

tube catcher 

on the tube filters with the teeth of the tool 

between tubes, directing the curve side of the 

tube catcher 

towards the right if you are right handed and left if you are 
left handed. With a gentle push you will be able to catch10 
tubes at once.

Step 3. Tube loading

Gently slide down the tubes in the 

tube magazine 

opening 

until all tubes are loaded. Remove the 

tube loader 

by pulling 

it smoothly away.

While using the 

tube loader 

tool is the most efficient way of 

loading 10 tubes at once, you can also load the 

tube loader 

by hand. With 2 fingers, gently pick up a fresh, unwrinkled 
cigarette tube at the filter. With the filter on the left, at 
~30 degree angle, introduce the tube filter first in the 

tube 

loader

. Drop the tube. Ensure that the tube is being placed 

correctly and gently in the 

tube loader

. Do not force the 

tube into the 

tube loader

. Repeat the operation until you 

have loaded all ten tubes. Note: Any damaged tubes will 

disturb a proper cigarette making cycle. In both loading 
ways, practice can be required.

Step 4. Tobacco loading

Use only tobaccos shown in the table printed on the hopper 
cover: the moisture level of the tobacco MUST be between 
12% to 20% (ideal 14% or 15%). The length of the tobacco 
cut MUST be between 1/4’’ to 5/8’’ (6mm to 16mm). The 
tobacco chopper and moisture meter supplied with the 

Automatic HSPT Golden Rainbow 10 + 

will help you adjust 

your tobacco to the perfect usage standards. Open the 
tobacco hopper cover and fill with ~0.5 oz (15 g) of tobacco 
to make 10 cigarettes, then close the cover. Note: Use 

of tobacco outside these specifications will jam and 

possibly damage the machine.

Step 5. Starting the cycle and completion

Set-up the tobacco compaction needed on the level 
control-setting knob (1 to 3).As you raise the level control 
setting you will get a higher degree of compaction in the 
tube. Through trial and error you can determine the best 
compact setting based on yourown test and the size of 
the filter of your favorite cigarette tube brand supplier. 
Softly press the “Start/stop/return” button one time to 
start the machine. This will produce 10 quality cigarettes 
automatically in 2.5 minutes. The machine will automatically 
stop at the end of the 10 cigarettes cycle.

If a problem occurs during cigarette cycle 

production, press the “Pause /Continue” 

button once and fix the issue by removing 

deteriorated material like damaged 

cigarette tubes or by removing excess 

tobacco, then resume the cigarette making 

cycle by pressing the “Pause/Continue” 

button once again.

CAUTION:

  Ideally, clean the machine after each cycle, never after more than three cycles. Turn off the power switch and 

unplug the machine. Empty the machine of all supplies. Next open the tobacco hopper and drawer and the machine tuned 
upside-down shaking it gently.  This will removed potential tobacco residues stock in the machine.  Then, using the brushes 
provided, clean the machine as show on the above pictures. Clean the tobacco wheels feeder inside the hopper by pushing 
tobacco inside the tobacco chamber (bottom of the tobacco hopper). Then, close the tobacco hopper cover. Turn the machine 
back on and run the machine for one cycle with the tube magazine empty to clean the excess tobacco.  Recycle the tobacco 
from the cleaning process, which might still remain on the cleaning mat (supplied).

Never leave your machine not cleaned when your production is over for the day.

Empty hopper

Remove the drawer for excess tobacco. 

1

HOW TO CLEAN