background image

Room Volume

in m

3

Total Volume of Liquid in ml

(based on 6ml/m

3

)

Estimated 

Fogging Time

20

120

36s

30

180

54s

50

300

1min 30s

100

600

3mins

200

1200

6mins

300

1800

9mins

VOLUME OF ELECTROX AND ESTIMATED TIME TO FOG

3

LEVEL OF PPE REQUIRED WHEN FOGGING

This is based on a work day of 8 hours. Users should not be continuously exposed for longer than 1 

hour before leaving the fogging process and removing the mask to take a break. This allows the user 

to work comfortably without the possibility of the mask being compromised during fogging. 

FURTHER INFORMATION

The Health and Safety Executive states that employers are responsible for determining their own 

working practices and in-house standards for control of exposure. 

For information on HSE Protective Equipment at Work: www.hse.gov.uk/pubns/books/hsg53.htm

For more information on FFP masks visit: www.hse.gov.uk/agriculture/dustmasks.htm

For information on Exposure Limits (WELs) visit www.hse.gov.uk/pUbns/priced/eh40.pdf.  

Concentration 

of Electrox

Level of FFP Mask required

No  Mask 

Required

FFP 1

FFP 2

FFP 3

100%

0-10mins

10-50mins

50mins –

2hr 5mins

2hr 5mins –

4hr 10mins

50%

0-25mins

25mins –

1hr 40mins

1hr 40mins –

4hr 10mins

4hr 10mins –

8hrs

10%

0-2hr 5mins

2hr 5mins –

8hrs

N/A

N/A

For a copy of the Safety Data Sheet for Electrox or if you have any questions about this booklet, 

please contact our Technical Director George Field, on 07772 551068 or email 

[email protected].

Содержание ElectroX

Страница 1: ...mited is dedicated to providing customers with the best and most reliable pH neutral electrolysed water product on the market today Customer and end user health and safety is of paramount importance to us The following guidelines show how to achieve the most effective use of Electrox Sterilising Water ...

Страница 2: ...ncentrations and time to reach the point at which PPE is required will need to be calculated Please contact the Electrox team for assistance with this if required ELECTROX CONCENTRATIONS Fogging with Electrox Sterilising Water can be undertaken in a variety of scenarios at different recommended concentrations These are listed below Medical Environment hospitals ambulances 100 Concentration Healthc...

Страница 3: ... 5 2 metres from one wall directing the fog towards the wall and move methodically around the room spraying walls tables chairs doors etc 7 Spray room from top to bottom to allow Electrox Sterilising Water fog to fall and decontaminate the air can clean area of air at a range of 4 metres For large rooms as well as fogging towards the walls walk steadily back an forth across the room moving backwar...

Страница 4: ...re responsible for determining their own working practices and in house standards for control of exposure For information on HSE Protective Equipment at Work www hse gov uk pubns books hsg53 htm For more information on FFP masks visit www hse gov uk agriculture dustmasks htm For information on Exposure Limits WELs visit www hse gov uk pUbns priced eh40 pdf Concentration of Electrox Level of FFP Ma...

Отзывы: