3. Steps for harnessing
3.1. Cable stripping
Strip cables in accordance with Crimping Quality Standards (ATAD-H0762/0763).
In so doing, make sure there is no scratch on cable cores.
3.2. Crimping
Crimped terminals to cables using an applicator (AP105-DF62W-**), and check the crimping
height and shape in accordance with the Table of crimping conditions and Crimping Quality
Standards (ATAD-H0762/0763). (** = 2022, 2226, 2830)
3.3. Insertion to crimping terminal sockets
Insertion to DF62W-
*
EP-2.2C and DF62W-
*
S-2.2C
Hold the cable of a crimped terminal, and insert it to each terminal hole of crimping sockets.
(Insert the terminal in the direction of arrows below.)
*The figures show insertion to DF62W-2poles connector.
For insertion, place the crimped terminal and crimping socket lock in the following direction.
Before inserting terminal
After inserting terminal
Lock: Right side
Plug terminal
Socket
Socket terminal
In-line plug
Direction of insertion
Contact No.: Upper
Lance holder: Upper
Lock: Left side
Contact No.: Upper
Lance holder: Upper
Figure 3-1. Terminal insertion