- 6 -
Connector clamp
Connector set OK
Connector clamp
Connector set NG
Connector clamp
②
Check polarization
mark
①
Connector main body
④
Connector clamp fails to work
Connector clamp
setting position
⑥
Connector holder
Position to make connector main body
come in contact with end face of
connector holder
Connector clamp
Connector
main body guide
width
Connector clamp set position
SET
(Slide to the left-hand side
)
OPEN
When the connector clamp is caught on the ground plate and not completely closed even when lightly pressing
it by fingers, it is considered that the preliminary insertion of the connector is not properly performed due to the
deformation of the ground plate or the like.
Do not perform the work by force. Return again to the state of the preliminary insertion of the ground plate
(Slide to the right-
hand side )
4. Setting procedure of the connector
1) Face upward polarization mark side
①
and slide
connector clamp
②
to the right-hand side to open it.
2) Adjust connector main body
④
to connector guide face
⑥
of connector holder
⑤
.
3) Making the connector main body come in contact with
end face of the connector holder, slide connector clamp
⑦
to the left-hand side to close it.
When the connector clamp is caught on the
ground plate and not closed by the spring
force alone, lightly press the connector
clamp by fingers up to the set position.