3
2.1.1. ON/OFF switch
For turning the inverter on/off.
2.1.2. Remote ON/OFF jack
Allows you to mount the inverter out of sight and turn ON or OFF with the included remote
control
2.1.3. Battery voltage (VOLTS) indicator
The battery voltage indicator displays the voltage at the input terminal of the inverter.
2.1.4. Battery current (AMPS) indicator
The battery current indicator displays the current drawn from the battery by the inverter.
Current should be in the green zone for continuous operation. In yellow zone the inverter will
work for several minutes, in the red zone the inverter protection will shut down the inverter.
2.1.5. POWER indicator
When connected to a battery and switched on, the power indicator illuminates green color:
ready for use.
2.1.6. OVER TEMPERATURE indicator
The over temperature indicator illuminates in yellow when the inverter is overheated. Also an
alarm will sound and the inverter will shutdown.
Overheating is caused by operating the inverter with power levels above its 2500W
continuous output. Also it will occur when it is installed somewhere where it cannot lose its
heat properly. The inverter will automatically restart when cooled down.
2.1.7 OVERLOAD indicator
The indicator will illuminate in red when an overload occurs. Problem can be solved by
switching it off and reducing the load before switching it on again.
2.1.8 AUDIBLE ALARM
Alarm will sound in case of:
a.
Over temperature
b.
Low battery (<10.5V for 12V inverter, <21V for 24V inverter)
c.
Low battery shutdown (<10V for 12V inverter, <20V for 24V inverter)