![HQ Power VDPLPS3 6 BP Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/hq-power/vdplps3-6-bp/vdplps3-6-bp_user-manual_2177131004.webp)
V D PLPS3 6 BP
V. 05 – 06/ 09/ 2013
4
© Velleman nv
•
Lighting effects are not designed for permanent operation: regular operation breaks will prolong their lives.
•
Do not shake the device. Avoid brute force w hen installing or operating the device.
•
Select a location w here the device is protected against extreme heat ( see “ Technical Specifications” ), dust
and moisture. Respect a minimum distance of 0.5m betw een the device’s light output and any illuminated
surface.
•
Use an appropriate safety cable to fix the device ( e.g. VDLSC8) .
•
Familiarise yourself with the functions of the device before actually using it. Do not allow operation by
unqualified people. Any damage that may occur w ill most probably be due to unprofessional use of the
device.
•
Use the original packaging if the device is to be transported.
•
All modifications of the device are forbidden for safety reasons.
4 .
Fe a ture s
•
PAR36 with 76 LEDs
•
DMX-controlled through 4 channels or stand- alone function
•
with w all mounting bracket
5 .
Ove rvie w
Refer to the illustrations on page 2 of this manual.
1
Pow er supply: 230VAC / 50Hz
4
Signal output: XLR connector connected w ith
next spot.
2
Fuse: 5 x 20mm F1A ( order code: FF1N)
5
DMX- address switches: Stand alone function or
DMX setting.
3
Signal input: XLR connector connected
with a DMX512 control panel.
6 .
I nsta lla tion
6 .1
DM X- 5 1 2 connect ions
•
Connect the provided XLR cable to the female 3- pin XLR output of your controller and the other side to the
male 3- pin XLR input of the VDPLPS36BP.
•
Multiple VDPLPS36BPs can be linked through serial linking.
•
The linking cable should be two core, screened cable with XLR input and output connectors. See diagram:
Cau tion
At the last fixture, the DMX cable has to be terminated with a terminator.
Only use a stereo shielded cable and 3- pin XLR- plugs and connectors in order to connect the controller with the
fixture or one fixture with another.
6 .2
Occupat ion of t he XLR- connect or
•
DMX terminator is recommended for installations w here the DMX cable has to run a long distance or is in an
electrically noisy environment ( e.g. discos) .
•
The terminator prevents corruption of the digital control signal by electrical noise.
•
The DMX terminator is simply an XLR plug with a 120Ω resistor betwe
en pins 2 and 3, w hich is then
plugged into the XLR output socket of the last device in the chain.
See illustrations on page 2.
6 .3
Project or DM X st art address select ion
•
All DMX- controlled devices need a digital start address so that the correct device responds to the signals.
This digital start address is the channel number from w hich the device starts to “listen” to the DMX
controller. Enter the correct number and read it from the display located on the base of the device.