Retain this card for operating instructions and warranty details

Please read carefully

Read these instructions completely before starting 

installation.

The infrared lamps heat by direct radiation rather than by 

heating the air in the room, so the Instant Heat 4 should be 

located directly over the drying area.

It must not be installed where there is a possibility of water 

splashing onto the lamps. Locate the Instant Heat 4 in 

accordance with the requirements of the SAA/SANZ Wiring 

Rules AS/NZS 3000 relating to damp situations. This means 

that no part of the Instant Heat 4 may be located directly 

above any part of the bath or shower recess or enclosure. For 

unenclosed showers refer to Wiring Rules conditions.

For information on switch locations, refer to Wiring Rules 

AS/NZS 3000

Note: Steam will only be removed if there is sufficient flow of 

air through the room. Ensure adequate inlets exist through 

windows, vents or under the door. Air flow path from the inlet 

to the fan should ideally pass over the steam sources. See over 

– ‘Getting the most from your Instant Heat 4’.

Note: Instant Heat 4 must be installed horizontally in ceiling 

by a licensed electrical contractor or similarly qualified person.

Regulations concerning the discharge of air have to be 

fulfilled. The Instant Heat has a free air discharge of 240m³/hr 

and care should be taken that airflow throughout meets 

specific requirements in building regulations. Local building 

codes may require venting to the outside. Ducting must be 

fitted and vented to the outside using exterior grille provided 

as shown in figure 1 and 2.

To duct to the outside connect the 

onto the outlet side of the exhaust 

fan. After installing the outlet grille 

to your eaves wall, connect the 

flexible duct (max 3m cut if 

necessary, remember to avoid 

bends etc) and affix using the duct 

tape provided.

Location:

The Instant Heat is for ceiling 

mounting only, with the lowest 

point to be at least 2.4 metres 

above floor level. It is not intended 

to be installed in wardrobes or 

within 300mm of sides of walls, as 

per Figure 3. There is a danger of 

combustion if placed too close to 

curtains or other flammable 

materials

Ceiling Preparation and 

Installation:

Instant Heat 4 may be installed in 

the ceiling cavity between joists 

using the built-in clip fasteners. 

Correct installation requires the 

cavity to have a minimum height of 

260mm for safe operation. The 

clearances between Instant Heat 

and surrounding joists and above 

ceiling shown in Figures 4 and 5 

shall be observed. Thermal 

insulation or similiar material shall 

not be placed on top of the Instant 

Heat, and adjacent material to the 

side shall be kept clear to a 

minimum distance of 300m. Joists, beams and rafters shall 

not be cut or notched to install Instant Heat.

AFTER DETERMINING LOCATION OF THE HEATER USE THIS 

CARD AS A TEMPLATE TO MARK OUT AND CUT AN APERTURE 

300 x 300mm (Fig 6).

If adequate support is not available for Instant Heat 4, it may 

be necessary to provide for extra strengthening.

Final assembly:
Check that the power to the unit is 
off. 

All models: 
Insert infrared lamps firmly into the 
sockets to ensure good electrical 
contact and long life. Centralise the 
lamp surround. Wipe the surround 
and bulbs clean. Connect the power 
and check all functions.

Wiring:
Three switches on an Excel wall plate are supplied. Snap the 
switches into the plate. Do not use with any solid state speed 
control. Wall plate should be located so that the switches are 
not within reach of a person in a bath or shower. Wiring 
connection is as per figure 8.
For information on switch locations, refer to Wiring Rules 
AS/NZS 3000

Standard roof application

 

Multi storey application

Fig 3

Fig 7

Fig 8

Fig 4

Fig 5

Fig 6

Fig 1

Fig 2

For additional information, contact HPM

Australia: 1300 369 777

New Zealand: 0800 476 009

www.hpm.com.au
Distibuted by HPM Industries Pty Ltd
PO BOX 6245
Silverwater, NSW  1811

210mm min 

height clearance

75mm side clearance

220mm

Joist

Joist

Joist

300mm

300mm

Fixing to ceiling:

Remove all lamps. Push the heat lamp body into the opening 

allowing the springs to snap open. To secure, push the lower 

ends of the springs apart. (Fig 7) The ceiling board thickness 

should be adjusted to enable the springs to be fitted without 

excessive force.

Instant Heat 4

Ducted Body

Template

3DSPEC

300mm

300mm

Wall