2     Sensor locations to be avoided

1.  Near water features such as swimming pools or ponds. The movement and reflections are likely to create nuisance switching.
2.  Near heat sources such as air conditioners, dryers, heaters or barbecues.
3.  Locations which are subject to drastic changes in temperature. 
4.  Locations which are subject to bright light such as direct sunlight.
5.  Locations frequented by animals such as pets or birds.

3     Installation

Switch off power source before installation. Ensure the power supply wiring comes from a circuit protected by a suitable fuse or circuit breaker. 
We recommend installing a wall switch for electrical isolation of the sensor. Refer to Fig. 3.
With reference to Fig. 2,
1.  Remove the screw from the terminal block cover.
2.  Connect wiring from power supply and load to the terminal block as marked. Refer to Fig. 3.
 

 

N: Neutral   L: Active / Line   1: Load

3.  Close the terminal block cover and re-do the screw. Ensure no bare wires are exposed.
4.  Fold back spring clips and insert sensor into the ceiling cut-out (630R02WE) or surface mount on the ceiling (630S02WE).

0.3 - 20mm

Ø65mm

630R02WE

3/4

CONTENTS

Technical data sheet: S000087115EN-2 

Updated: 18/02/2016 

Created: 09/03/2015

Catalogue number(s): 0 489 41/44/48

Compact motion sensors - PIR

  5. INSTALLATION

5.1   Positioning the sensor

PIR

5.2   Positioning

1

2

3

4

Ø 65

0,3 - 20 mm

8mm max.

4mm max.

79mm

0 489 41/44

0 489 48

630S02WE

Fig. 2