Fig. 2
2 Sensor locations to be avoided
1. Near water features such as swimming pools or ponds. The movement and reflections are likely to create nuisance switching.
2. Near heat sources such as air conditioners, dryers, heaters or barbecues.
3. Locations which are subject to drastic changes in temperature.
4. Locations which are subject to bright light such as direct sunlight.
5. Locations frequented by animals such as pets or birds.
3 Installation
Switch off power source before installation. Ensure the power supply wiring comes from a circuit protected by a suitable fuse or circuit breaker.
We recommend installing a wall switch for electrical isolation of the sensor. Refer to Fig. 3.
With reference to Fig. 2,
1. Remove the screw from the terminal block cover.
2. Connect wiring from power supply and load to the terminal block as marked. Refer to Fig. 3.
N: Neutral L: Active / Line 1: Load
3. Close the terminal block cover and re-do the screw. Ensure no bare wires are exposed.
4. Fold back spring clips and insert sensor into the ceiling cut-out (630R02WE) or surface mount on the ceiling (630S02WE).
0.3 - 20mm
Ø65mm
630R02WE
3/4
CONTENTS
Technical data sheet: S000087115EN-2
Updated: 18/02/2016
Created: 09/03/2015
Catalogue number(s): 0 489 41/44/48
Compact motion sensors - PIR
5. INSTALLATION
5.1 Positioning the sensor
PIR
5.2 Positioning
1
2
3
4
Ø 65
0,3 - 20 mm
8mm max.
4mm max.
79mm
0 489 41/44
0 489 48
630S02WE
Fig. 2