TIP:
The supplied cables are labeled on each end
in the following convention:
N:S3:P2 -
J1:I2:P1
, where N = Node, S = Slot, P = Port, J
= JBOD, D = Drawer, and I = I/O Module.
Check the labels to determine which cable to use.
The labels are the same on both ends of the cable.
Procedure
•
StoreOnce 5200:
Use the supplied HD SAS cables
to connect the node server RAID controller card to
the base storage enclosure.
Cable
Length
From
To
A
2 m
N:S3:P2
J1:I2:P1
B
1 m
N:S3:P1
J1:I1:P1
•
StoreOnce 5250 and 5650:
Connect the supplied
SAS cables as shown.
Cable
Length From
To
A
2 m
N:S3:P2
J
F
:D2:IB:P2
F
=1
B
1 m
N:S3:P1
J1:D1:IA:P1
C
0.5 m
J1:D2:IB:P1 J1:D1:IB:P2
D
0.5 m
J1:D2:IA:P1 J1:D1:IA:P2
Connecting the storage enclosure power
cables
Procedure
•
StoreOnce 5200:
Connect two power cables to each
enclosure. Connect each power cable to a different
PDU.
•
StoreOnce 5250 and 5650:
Connect four power
cables to each enclosure. Connect each power cable
to a different PDU.
Connecting the system cables
Procedure
1.
Connect the power cables.
Connect each power cable to a separate PDU in the
rack.
2.
Connect a network cable to LAN port 1.
3.
Connect a network cable to the iLO port
(recommended).
4.
If you are not using iLO for initial configuration,
connect a VGA monitor and a USB keyboard.
Powering on the system
Prerequisites
All storage enclosures must be installed and cabled
before the system is powered on. For instructions about
installing optional storage enclosures, see the
HPE
StoreOnce 3620, 3640, 5200, 5250, and 5650 Systems
Installation Guide
.
Page 6