Table 3: Extended Edgeline specifications
Specification
Value
—
Operating
0°C to 55°C (32°F to 131°F)
Nonoperating
-30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
—
Operating
8% to 90% at 28°C (82.4°F) maximum wet bulb temperature
Non-Operating
5% to 95% at 38.7°C (101.7°F) maximum wet bulb
temperature
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1,000 ft) to 3,048 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). No restrictions on product configurations
except for rotating hard drives. PCI cards must be rated for continuous operation with 60°C cooling air. Solid-state drives must be rated for
continuous operation with 65°C cooling air. Not rated for operation over 3,030 m (10,000 ft).
Mechanical specifications
Specification
Value
Height
16.71 cm (6.57 in)
Depth
1.98 cm (0.78 in)
Width
18.37 cm (7.23 in)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
•
1500W -48VDC Hot Plug Power Supply
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise website (
www.hpe.com/info/proliant/powersupply).
1500W Hot-plug Power Supply
Specification
Value
Input requirements
—
Rated input voltage
90 VAC to 264 VAC
Table Continued
174 Specifications
Содержание ProLiant e910
Страница 148: ...148 Customer self repair...
Страница 149: ...Customer self repair 149...
Страница 150: ...150 Customer self repair...
Страница 158: ...c Remove the PCIe riser board Right PCIe riser board Left PCIe riser board 158 Removal and replacement procedures...
Страница 182: ...UID unit identification UEFI Unified Extensible Firmware Interface 182 Acronyms and abbreviations...