Operations
Powering up the HPE Edgeline EL8000 Converged Edge chassis
If the HPE Edgeline EL8000 Converged Edge chassis is connected to a power source, it powers up automatically by default.
Generally, it has to be powered up only after a manual shutdown.
Procedure
1. Connect the power cables to the power supplies.
2. Connect the power cables to the power source (UPS or wall outlet) or to an installed PDU.
3. Make sure that the power supply LED is green.
Powering up the server blade
Blades can be powered up individually in the chassis. Choose the procedure that fits your need.
When each blade is installed into a powered chassis, auxiliary power is automatically provided to the blade, which powers the
blade iLO module.
Use one of the following methods to power on blades:
• Press and release the power button on the server blade.
•
Use the virtual power button in the Edgeline EL8000 Chassis Manager web interface.
•
Use the virtual power button in the iLO web interface hosted on the blade.
• Enter the
set power on b
<slot#>
at the chassis manager CLI. See the HPE Edgeline EL8000 Converged Edge
System Chassis Manager CLI User Guide on the
HPE website for details on CLI commands.
• Enter
Power
at the iLO CLI.
Before proceeding, verify that the server blade is powered on by observing that the system power LED is green. See
Installing the server blade into the chassis
The HPE Edgeline EL8000 Converged Edge chassis supports HPE ProLiant e910 Server Blade. Permissible server blades
configurations:
• Up to four 1U server blades
• Up to two 2U server blades
• Up to one 2U and two 1U server blades
IMPORTANT: The 2U server blades must be installed in bay 1 and bay 5.
Prerequisites
Before performing this procedure, make sure that you have the T-15 Torx key available.
Operations
17
Содержание ProLiant e910
Страница 148: ...148 Customer self repair...
Страница 149: ...Customer self repair 149...
Страница 150: ...150 Customer self repair...
Страница 158: ...c Remove the PCIe riser board Right PCIe riser board Left PCIe riser board 158 Removal and replacement procedures...
Страница 182: ...UID unit identification UEFI Unified Extensible Firmware Interface 182 Acronyms and abbreviations...